ABSTRACT
A right ventricular artificial demand pacemaker was implanted into a 59-year- old man with supra-Hisian complete heart block. His postoperative course was complicated by Staphylococcal aureus seplicemia. which was controlled with antibiotics. A year later, S. aureus was again isolated from the blood. Echo- cardiography showed thickening of the tricuspid valve leaflet and multiple echoes in the right atrium. Autopsy findings included tricuspid leaflet thickening and an overlying right atrial thrombus. The echocardiogram is thus useful in localizing an infected valve in bacterial endocarditis and in demonstrating the presence of the thrombus.
ACCESSION #
16921031

 

Related Articles

  • Antibiotics for permanent pacemaker implantation. APGAR, BARBARA // American Family Physician;10/15/1998, Vol. 58 Issue 6, p1449 

    Presents the abstract of the article `Antibiotic prophylaxis for permanent pacemaker implantation. A meta-analysis,' by A. Da Costa from the `Circulation' journal dated May 1998.

  • Tricuspid Valve Perforation by Permanent Pacemaker Lead. Erdinler, Izzet; Okmem, Ertan; Turek, Onur; Yapici, Fikri; Ozler, Azmi; Cam, Nese; Ulufer, Tanju // Angiology;Sep/Oct2005, Vol. 56 Issue 5, p619 

    Tricuspid valve perforation with pacemaker lead is one of the extremely rare complications of transvenous pacemaker implantation. Approximately all reported cases have been diagnosed at autopsy. The authors present a case of tricuspid valve perforation caused by pacemaker lead that was diagnosed...

  • Surgical Treatment Of Right Sided Valvular Endocarditis. Okur, Faik Fevzi; Mese, Timur; Tavli, Vedide; Saritas, Turkay; Saylan, Berna; Alayunt, Alp // Internet Journal of Thoracic & Cardiovascular Surgery;2007, Vol. 8 Issue 2, p4 

    Reports of tricuspid endocarditis have increased in frequency during the past 2 decades [1][2]. The growing number of patients addicted to intravenous (IV) drugs and those with long-term IV catheters or with antiarrhythmic devices, such as implantable defibrillators and pacemakers, have...

  • Safety of magnetic resonance imaging in patients with permanent pacemakers: a collaborative clinical approach. Boilson, Barry; Wokhlu, Anita; Acker, Nancy; Felmlee, Joel; Watson, Robert; Julsrud, Paul; Friedman, Paul; Cha, Yong-Mei; Rea, Robert; Hayes, David; Shen, Win-Kuang // Journal of Interventional Cardiac Electrophysiology;Jan2012, Vol. 33 Issue 1, p59 

    Objective: This study aimed to characterize the interactions of pacemakers with magnetic resonance imaging (MRI) and to identify device characteristics that could predict adverse interactions. Background: The safety of MRI in patients with indwelling pacemaker systems remains uncertain. Previous...

  • Evaluation of rheumatic tricuspid valve stenosis by real-time three-dimensional echocardiography. Anwar, Ashraf M.; Geleijnse, Marcel L.; Soliman, Osama I. I.; Mcghie, Jackie S.; Nemes, Aitila; Ten Cate, Folkert J. // Heart;Mar2007, Vol. 93 Issue 3, p363 

    The article discusses a study which examined the use of transthoracic real-time three-dimensional echocardiography (RT3DE) in assessing patients with rheumatic tricuspid valve stenosis. RT3DE can assess each separate tricuspid valve leaflet with regards to thickness, mobility, calcification and...

  • A rabbit model of right-sided Staphylococcus aureus endocarditis created with echocardiographic guidance. Mei-lian Wang; Ying Zhang; Miao Fan; En-jie Luo // Cardiovascular Ultrasound;2013, Vol. 11 Issue 1, p1 

    Background: The most widely used experimental models of infective endocarditis (IE) are the rabbit and rat models, in which cardiac valve lesions are induced by a polyethylene catheter introduced into the left ventricle through the aortic valve. Our study was designed to create a rabbit model of...

  • Giant Right Atrial Myxoma With Rheumatic Mitral Valve Disease. Pores, Ira H.; Abel, Ronald M.; Gray, Lewis; Jacobs, Glen P. // Angiology;May1984, Vol. 35 Issue 5, p313 

    A patient with a 456 Gram right atrial myxoma is described. Associated rheumatic mitral valvular heart disease obscured the presence of the tumor and only with presentation of bradyarrhythmias leading to pacemaker implantation was the diagnosis suspected. Successful surgical removal of the tumor...

  • Extraktion einer infizierten Schrittmacherelektrode mittels Lasersheath. ElFarra, Hamdi; Moosdorf, Rainer; Kratz, Thomas; Grimm, Wolfram // Herzschrittmachertherapie und Elektrophysiologie;Sep2013, Vol. 24 Issue 3, p189 

    A case of pacemaker electrode infection with Staphylococcus aureus is presented. In order to avoid sternotomy, the right ventricular pacemaker lead, which had been implanted for 15 years, was successfully extracted using a laser sheath despite large endocarditic vegetations on the pacemaker...

  • OLDER PATIENTS LIKE REMOTE MONITORING, BUT PREFER IN PERSON VISITS.  // Heart Advisor;May2013, Vol. 16 Issue 5, p2 

    The article discusses a study which shows that older patients with pacemakers, defibrillators and other implanted, wireless devices that regulate or measure heart rhythm prefer in-office follow-ups with their doctors.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics