TITLE

TLD

PUB. DATE
January 2005
SOURCE
Taber's Cyclopedic Medical Dictionary;2005, p2196
SOURCE TYPE
Book
DOC. TYPE
Reference Entry
ABSTRACT
A definition of the term "TLD," is presented. It means thermoluminescent dosimeter.
ACCESSION #
21248787

 

Related Articles

  • Laser-stimulated thermoluminescence. II. Kelly, Paul; Abtahi, Abdollah; Braunlich, Peter F. // Journal of Applied Physics;1/15/1987, Vol. 61 Issue 2, p738 

    Presents a study that examined laser-stimulated thermoluminescence from thin-layer lithium fluoride: magnesium, titanium dosimeters. Methodology; Details on the computational approach; Comparison of experimental and computer simulated thermoluminescence response curves.

  • DOSIMETRIC PROPERTIES OF NEW CARDS WITH HIGH-SENSITIVITY MCP-N (LiF:Mg,Cu,P) DETECTORS FOR HARSHAW AUTOMATIC READER. Budzanowski, M.; Bilski, P.; Olko, P.; Ryba, E.; Perle, S.; Majewski, M. // Radiation Protection Dosimetry;2007 Special Issue, Vol. 125 Issue 1-4, p251 

    A new configuration for a thermoluminescent dosimetric card has been developed through collaboration between the Institute of Nuclear Physics in Krakow and several commercial dosimetric companies. The card is based on high-sensitivity LiF:Mg,Cu,P circular pellets (MCP-N) welded inside synthetic...

  • BACKGROUND CORRECTION OF PERSONAL DOSE DISTRIBUTIONS BY A NOVEL UNFOLDING ALGORITHM. Stadtmann, H.; Aschbacher, A. // Radiation Protection Dosimetry;2007 Special Issue, Vol. 125 Issue 1-4, p395 

    The dosimetry service Seibersdorf monitors more than 20,000 persons with typical monitoring period of one month. The use of thermoluminescence (TL)-dosemeters during the last 30 years allows measurements of even low dose values (some 10 µSv) with sufficient uncertainty. Consideration of the...

  • ESTUDIO DE LA DEPENDENCIA GEOMETRICA DURANTE EL POSICIONAMIENTO DE MATERIAL TERMOLUMINISCENTE EN EQUIPOS LECTORES TLD. D. H., Olaya; G. E. Y., Soto; S. A., Martinez; V. U., Chica // Revista Colombiana de Física;2006, Vol. 38 Issue 3, p1315 

    In this work was used two types of thermoluminiscent material such as TLD powder and TLD chips. The dosimeters were irradiated using a 137Cs source, then were reading in the Harshaw 4500 reader of the Individual Radiological Survellaince Group belongs INGEOMINAS, putting the thermoluminiscent...

  • Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. Ludlow, J.B.; Davies-Ludlow, L. E.; Brooks, S. L.; Howerton, W. B. // Dentomaxillofacial Radiology;Jul2006, Vol. 35 Issue 4, p219 

    Objectives: Cone beam computed tomography (CBCT), which provides a lower dose, lower cost alternative to conventional CT, is being used with increasing frequency in the practice of oral and maxillofacial radiology. This study provides comparative measurements of effective dose for three...

  • VARIATIONS IN BACKSCATTER OBSERVED IN PMMA WHOLE-BODY DOSIMETRY SLAB PHANTOMS.  // Radiation Protection Dosimetry;Feb2008, Vol. 128 Issue 3, p375 

    Polymethyl methacrylate (PMMA) is a useful material for dosimetry phantoms in many ways including approximate tissue equivalence, stability, accessibility and ease of use. However, recent studies indicate that PMMA may have some unanticipated variation in backscatter from one phantom to another....

  • INDIVIDUAL MONITORING BASED ON MAGNESIUM BORATE. Prokić1, Mirjana // Radiation Protection Dosimetry;2007 Special Issue, Vol. 125 Issue 1-4, p247 

    Valuable features of magnesium borate sintered solid thermoluminescence dosemeters (TLDs), such as near tissue-equivalence, high sensitivity, and good performances for X, gamma, beta and neutron dosimetry, were developed and produced by the Institute of Nuclear Sciences, Vinča. These features...

  • COMPARISON OF THE EFFECTS OF EXPOSURE TO LIGHT IN HARSHAW LiF:Mg,Ti AND LIF:Mg,Cu,P. Baker, S. T.; Gilvin, P. J. // Radiation Protection Dosimetry;2007 Special Issue, Vol. 125 Issue 1-4, p258 

    The response of thermoluminescence dosemeters (TLDs) to light, in various conditions, has been studied. TLD cards containing both conventional lithium fluoride (LiF:Mg,Ti) and the high-sensitivity material LiF:Mg-Cu,P were available, so permitting a comparison between the two types. Also...

  • TL DETECTORS FOR GAMMA RAY DOSE MEASUREMENTS IN CRITICALITY ACCIDENTS. Miljanić, Saveta; Zorko, Benjamin; Gregori, Beatriz; Knežvić, Željka // Radiation Protection Dosimetry;2007 Special Issue, Vol. 125 Issue 1-4, p318 

    Determination of gamma ray dose in mixed neutron + gamma ray fields is still a demanding task. Dosemeters used for gamma ray dosimetry are usually in some extent sensitive to neutrons and their response variations depend on neutron energy i.e., on neutron spectra. Besides, it is necessary to...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics