TITLE

Subclavian artery access for transcatheter aortic valve implantation and cardiopulmonary support

AUTHOR(S)
Lentini, Salvatore; Gaeta, Roberto
PUB. DATE
November 2010
SOURCE
Perfusion;Nov2010, Vol. 25 Issue 6, p425
SOURCE TYPE
Academic Journal
DOC. TYPE
Letter
ABSTRACT
A letter to the editor is presented regarding transcatheter aortic valve implantation (TAVI), a treatment for patients suffering from aortic valve stenosis.
ACCESSION #
55472890

 

Related Articles

  • Expanding Role for Transcatheter Aortic Valve Replacement: Successful Transfemoral Implantation of a Medtronic CoreValve for Severe Aortic Regurgitation Yeow, W.L.; Roberts-Thomson, P.; Shetty, S.; Yong, G. // Heart, Lung & Circulation;Nov2012, Vol. 21 Issue 11, p754 

    Severe aortic regurgitation (AR), when intervention is required, is best managed by surgical aortic valve replacement (SAVR). Transcatheter aortic valve replacement (TAVR) for aortic stenosis has recently shown non-inferiority to SAVR and superiority to medical management. Here we describe a...

  • Repair of the calcified bicuspid aortic valve Urbanski, Paul P. // European Journal of Cardio-Thoracic Surgery;Apr2011, Vol. 39 Issue 4, p603 

    Abstract: The novel repair technique of calcified bicuspid aortic valve is described, in which the calcified body of the cusps is repaired with autologous pericardium leaving the native free margin and commissures in place for anchoring. The technique has been used in 48 consecutive patients...

  • Transcatheter aortic valve-in-surgical aortic valve implantation: current status and future perspectives. Lange, RĂ¼diger; Piazza, Nicolo // European Journal of Cardio-Thoracic Surgery;Sep2013, Vol. 44 Issue 3, p403 

    The author discusses the status and future perspectives of transcatheter aortic valve-in-surgical aortic valve implantation. The author states that relative use of surgical bioprosthetic valves has increased because of improved surgical techniques, valve durability, and patient's preference. He...

  • Aortic valve repair and Ross operation in children: the importance of patient selection and surgical technique. Mastrobuoni, Stefano; Khoury, Gebrine El // European Journal of Cardio-Thoracic Surgery;Mar2016, Vol. 49 Issue 3, p892 

    The author reflects on the study by Wilder and colleagues regarding the significance of patient selection and surgical technique in aortic valve repair and Ross operation in children. The study was performed to children who received either aortic valve repair, Ross procedure or aortic valve...

  • Women less likely to die after TAVR.  // Cardiology Today;Nov2012, Vol. 15 Issue 11, p23 

    The article discusses a study which concluded that women with severe aortic stenosis are less likely to die after transcatheter aortic valve replacement.

  • Technology Prevails: The Long-Awaited Transcatheter Aortic Valve Replacement Device. Shepherd, Maria // Medical Product Outsourcing;Nov/Dec2010, Vol. 8 Issue 9, p32 

    The article focuses on the importance of Transcatheter Aortic Valve Replacement device in the treatment of patients with severe aortic stenosis in the U.S. It states that the advantages of the new device were discussed during the 2010 Euro polymerase chain reaction (PCR) meeting in Paris, France...

  • Thrombus formation due to flow competition after apico-aortic conduit Takahashi, Yosuke; Tsutsumi, Yasushi; Monta, Osamu; Ohashi, Hirokazu // European Journal of Cardio-Thoracic Surgery;Apr2010, Vol. 37 Issue 4, p978 

    Abstract: We report a case of unusual thrombus formation and describe the risk of perioperative myocardial infarction or stroke in severe aortic stenosis after apico-aortic conduit. An 86-year-old woman was admitted with aggravation of dyspnoea on exertion and chest pain. She was complicated...

  • The SOURCE Registry: what is the learning curve in trans-apical aortic valve implantation? Wendler, Olaf; Walther, Thomas; Schroefel, Holger; Lange, RĂ¼diger; Treede, Hendrik; Fusari, Melissa; Rubino, Paolo; Thomas, Martyn // European Journal of Cardio-Thoracic Surgery;Jun2011, Vol. 39 Issue 6, p853 

    Abstract: Objective: Trans-apical aortic valve implantation (TA-AVI) has been shown to be a reproducible technique. Early results from the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry identified major access complications associated with high 30-day mortality. Using the SOURCE...

  • Low output, low gradient aortic stenosis. MacCarthy, P.; Berger, A.; de Bruyne, B. // Heart;May2003, Vol. 89 Issue 5, p474 

    Describes a case of severe dyspnea of effort who had undergone homograft aortic valve replacement for aortic stenosis. Results of cardiac catheterization; Increase in aortic valve area on dobutamine challenge; Importance of interpreting changes in valve area, valve gradient and cardiac output.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics