TITLE

The Control Technology of the Z-source Three-phase Four-leg Inverter based on Computer Simulation

AUTHOR(S)
Ming Su; Xueyan Ma; Yan Sun
PUB. DATE
July 2014
SOURCE
Advanced Materials Research;2014, Vol. 981, p688
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same leg conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth leg uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load.
ACCESSION #
99565075

 

Related Articles

  • Design and Experimentation of Boost Cascaded DC Link Inverter for Domestic UPS Applications. Uthirasamy, R.; Ragupathy, U. S. // Journal of Circuits, Systems & Computers;Dec2015, Vol. 24 Issue 10, p-1 

    A new structure of Boost Cascaded DC Link H-Bridge Inverter (BCDCLHBI) is proposed for domestic UPS applications. It consists of DC-DC converter, sub-multilevel modules and H-bridge inverter circuits. The proposed sub-multilevel modules synthesize a stepped DC link voltage with reduced voltage...

  • Coordinated Control of Dual PWM Converter for Elevator Drives. Han Shuang; Zheng Jiong; Luo Zhiqun; Wan Jianru // Elevator World;Jul2012, Vol. 60 Issue 7, p50 

    The article focuses on the coordinated control of dual pulse-width modulation (PWM) converters integrating elevator drives with energy feedback. It states that the energy difference between the rectifier and inverter per unit time can decrease if the power flow of the rectifier equals the...

  • Performance and Measurement of Current Control Schemes in Grid connected Inverters. Yuvaraja, T.; Gopinath, M. // Australian Journal of Basic & Applied Sciences;Jun2014, Vol. 8 Issue 9, p163 

    Background: Applications such as digital based control in grid connected output currents are measured accurately. So obtaining the accuracy I must in the design consideration. The proposed work analyze the single and three phase measurement of grid connected inverter and the current control...

  • Zero-voltage-switching DC/AC inverter. Wang, C.-M. // IET Electric Power Applications;May2007, Vol. 1 Issue 3, p387 

    A novel zero-voltage-switching (ZVS) DC/AC inverter is proposed. The proposed inverter can not only provide output voltage that is higher or lower than DC input voltage but can also use the pulse-width modulation (PWM) control technique. Furthermore, in the proposed inverter, besides operating...

  • Line-modulation-based flux-weakening control for permanent-magnet synchronous machines. Wei Wang; Jinghao Zhang; Ming Cheng // IET Power Electronics;2018, Vol. 11 Issue 5, p930 

    A line-modulation-based flux-weakening control is proposed for surface-mounted permanent-magnet synchronous machines. To evaluate the average dc bus voltage utilisation, the maximum line-modulation-ratio, which cannot be >1, is defined. If the maximum line-modulation-ratio is equal to 1, the...

  • Dynamic voltage restorer based on multilevel inverter with adjustable dc-link voltage. Babaei, Ebrahim; Kangarlu, Mohammad Farhadi; Sabahi, Mehran // IET Power Electronics;Mar2014, Vol. 7 Issue 3, p576 

    Dynamic voltage restorer (DVR) is a power electronic converter-based custom power device used to compensate for voltage variations. The inverter used in the DVR structure can have different topologies. Multilevel inverters are a good candidate to be used in the DVR structure especially in higher...

  • An IFOC-DSVPWM Based DC-Link Voltage Compensation of Z-Source Inverter Fed Induction Motor Drive for EVs. Akkarapaka, Ananda Kumar; Singh, Dheerendra // Advances in Power Electronics;8/13/2015, Vol. 2015, p1 

    The drop in DC-link voltage of adjustable speed drives (ASD) occurs mainly due to the increase in output power demands. This may lead to inefficient operation and eventually the tripping of the drive. This paper presents a Double Space Vector Pulse Width Modulation (DSVPWM) technique for...

  • Single-phase multilevel inverter topologies with self-voltage balancing capabilities. Gautam, Shivam Prakash; Kumar, Lalit; Gupta, Shubhrata // IET Power Electronics;2018, Vol. 11 Issue 5, p844 

    In this study, two new structures of single-phase hybrid multilevel inverter are proposed for both symmetrical and asymmetrical configurations that can be employed in drives and control of electrical machines and connection of renewable energy sources. The proposed configuration uses a less...

  • The X-connected inverter: a topology with higher fundamental and reduced low-order harmonic voltages. Maiti, Dipten; Biswas, Sujit K. // IET Power Electronics;Nov2013, Vol. 6 Issue 9, p1851 