TITLE

Development of a Surface Plasmon Resonance Biosensing Approach for the Rapid Detection of Porcine Circovirus Type2 in Sample Solutions

AUTHOR(S)
Hu, Jiandong; Wang, Tingting; Wang, Shun; Chen, Mingwen; Wang, Manping; Mu, Linying; Chen, Hongyin; Hu, Xinran; Liang, Hao; Zhu, Juanhua; Jiang, Min
PUB. DATE
October 2014
SOURCE
PLoS ONE;Oct2014, Vol. 9 Issue 10, p1
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A sensitive and label-free analytical approach for the detection of porcine circovirus type 2 (PCV2) instead of PCV2 antibody in serum sample was systematically investigated in this research based on surface plasmon resonance (SPR) with an establishment of special molecular identification membrane. The experimental device for constructing the biosensing analyzer is composed of an integrated biosensor, a home-made microfluidic module, and an electrical control circuit incorporated with a photoelectric converter. In order to detect the PCV2 using the surface plasmon resonance immunoassay, the mercaptopropionic acid has been used to bind the Au film in advance through the known form of the strong S-Au covalent bonds formed by the chemical radical of the mercaptopropionic acid and the Au film. PCV2 antibodies were bonded with the mercaptopropionic acid by covalent -CO-NH- amide bonding. For the purpose of evaluating the performance of this approach, the known concentrations of PCV2 Cap protein of 10 µg/mL, 7.5 µg/mL, 5 µg/mL, 2.5 µg/mL, 1 µg/mL, and 0.5 µg/mL were prepared by diluting with PBS successively and then the delta response units (ΔRUs) were measured individually. Using the data collected from the linear CCD array, the ΔRUs gave a linear response over a wide concentration range of standard known concentrations of PCV2 Cap protein with the R-Squared value of 0.99625. The theoretical limit of detection was calculated to be 0.04 µg/mL for the surface plasmon resonance biosensing approach. Correspondingly, the recovery rate ranged from 81.0% to 89.3% was obtained. In contrast to the PCV2 detection kits, this surface plasmon resonance biosensing system was validated through linearity, precision and recovery, which demonstrated that the surface plasmon resonance immunoassay is reliable and robust. It was concluded that the detection method which is associated with biomembrane properties is expected to contribute much to determine the PCV2 in sample solutions instead of PCV2 antibody in serum samples quantitatively.
ACCESSION #
99201407

 

Related Articles

  • Real-time monitoring of biomolecular interactions in blood plasma using a surface plasmon resonance biosensor. Špringer, Tomáš; Piliarik, Marek; Homola, Jiří // Analytical & Bioanalytical Chemistry;Nov2010, Vol. 398 Issue 5, p1955 

    We report a novel approach to biosensor-based observations of biomolecular interactions which enables real-time monitoring of biomolecular interactions in complex media. This approach is demonstrated by investigating the interaction between the human chorionic gonadotropin (hCG) and its antibody...

  • Determination of Binding Potency of Peptidic Inhibitors of Grb2-SH2 by Using the Protein-Captured Biosensor Method. Lung, Feng-Di T.; Wan-Ching Li; Yung-Hsien Chang; Hui-Ming Chen // Protein & Peptide Letters;Aug2008, Vol. 15 Issue 8, p806 

    The growth factor receptor-binding protein 2-Src homology 2 (Grb2-SH2) domain plays an important role in the oncogenic Ras signal transduction pathway, therefore, peptidic inhibitors of the Grb2-SH2 domain has been chosen as our target for the development of antiproliferative agents. The...

  • Red blood cells do not attenuate the SPCE fluorescence in surface assays. Matveeva, Evgenia G.; Gryczynski, Ignacy; Barnett, Anne; Calander, Nils; Gryczynski, Zygmunt // Analytical & Bioanalytical Chemistry;Jul2007, Vol. 388 Issue 5/6, p1127 

    We describe the positive effect of surface plasmon-coupled fluorescence emission (SPCE) on the detection of a signal from a surface immunoassay in highly absorbing or/and scattering samples. A model immunoassay using fluorescently labeled anti-rabbit antibodies that bind to rabbit immunoglobulin...

  • A label-free optical detection method for biosensors and microfluidics. Xiaonan Shan; Foley, Kyle J.; Nongjian Tao // Applied Physics Letters;3/31/2008, Vol. 92 Issue 13, p133901 

    A label-free detection method is developed for biosensors and for microfluidic applications. Multiple optical modes, including a conventional surface plasmon resonance (SPR) mode and many bulk modes, are created in a microfluidic channel with metallic coatings on top and bottom. The bulk modes...

  • Surface plasmon resonance biosensor for the detection of VEGFR-1-a protein marker of myelodysplastic syndromes. Pimková, Kristýna; Bocková, Markéta; Hegnerová, Kateřina; Suttnar, Jiří; Čermák, Jaroslav; Homola, Jiří; Dyr, Jan // Analytical & Bioanalytical Chemistry;Feb2012, Vol. 402 Issue 1, p381 

    The surface plasmon resonance (SPR) biosensor system with dispersionless microfluidics for the direct and label-free detection of a soluble vascular endothelial growth factor receptor (sVEGFR-1) is described. The detection approach takes advantage of an affinity interaction between sVEGFR-1 and...

  • Surface plasmon resonance biosensor based on Hg/Ag–Au film. Ying Sun; Daqian Song; Zhongqiu Li; Yu Bai; Hanqi Zhang // Analytical & Bioanalytical Chemistry;Mar2007, Vol. 387 Issue 5, p1875 

    Mercury or silver was electrodeposited on an Au surface to form an Hg–Au or Ag–Au film. Wavelength-modulation SPR biosensors based on this Hg/Ag–Au film were then used to determine human IgG and rabbit IgG. When direct immunoreactions were performed on the Au sensing...

  • Microchannel chips for the multiplexed analysis of human immunoglobulin G—antibody interactions by surface plasmon resonance imaging. Yi Dong; Wilkop, Thomas; Danke Xu; Zhuangzhi Wang; Quan Cheng // Analytical & Bioanalytical Chemistry;Mar2008, Vol. 390 Issue 6, p1575 

    We report the multiplexed, simultaneous analysis of antigen–antibody interactions that involve human immunoglobulin G (IgG) on a gold substrate by the surface plasmon resonance imaging method. A multichannel, microfluidic chip was fabricated from poly(dimethylsiloxane) (PDMS) to...

  • Antibody characterization and immunoassays for palytoxin using an SPR biosensor. Yakes, Betsy Jean; DeGrasse, Stacey L.; Poli, Mark; Deeds, Jonathan R. // Analytical & Bioanalytical Chemistry;Oct2011, Vol. 400 Issue 9, p2865 

    Palytoxin (PLTX), a polyether marine toxin originally isolated from the zoanthid Palythoa toxica, is one of the most toxic non-protein substances known. Fatal poisonings have been linked to ingestion of PLTX-contaminated seafood, and effects in humans have been associated with dermal and...

  • No job too small.  // Nature Materials;Jun2008, Vol. 7 Issue 6, p419 

    The article discusses various reports published within the issue including one on surface plasmon effects and another on successful imaging approach by surface plasmon.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library