TITLE

Phillips–Tikhonov regularization of plasma image reconstruction with the generalized cross validation

AUTHOR(S)
Iwama, Naofumi; Yoshida, Hiromasa; Takimoto, Hitoshi; Shen, Yun; Takamura, Shuichi; Tsukishima, Takashige
PUB. DATE
February 1989
SOURCE
Applied Physics Letters;2/6/1989, Vol. 54 Issue 6, p502
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The use of the Phillips–Tikhonov regularization is proposed for numerically stabilizing the ill-conditioned plasma image reconstructions. An objective function to be minimized leads to a linear estimator of the image intensity distribution and, with the aid of the singular value decomposition, makes it possible to use the generalized cross validation for optimizing a regularization parameter. An excellent behavior of the estimator with computational facility is obtained on the Hα emission computerized tomography of a toroidal plasma.
ACCESSION #
9829893

 

Related Articles

  • Computerized tomographic imaging for space plasma physics. Zhang, Yuhong; Coplan, Michael A.; Moore, John H.; Berenstein, Carlos A. // Journal of Applied Physics;12/1/1990, Vol. 68 Issue 11, p5883 

    Presents a computerized tomographic imaging model for space plasma physics. Background on x-ray tomography; Aspect important in tomographic measurement; Mathematical foundations of computerized tomography imaging; Electromagnetic-field configurations upon which the design of a tomographic...

  • Spectroscopic plasma tomography with multiple photocollector arrays. Sugimoto, Satoshi; Goto, Seiich // Review of Scientific Instruments;Sep91, Vol. 62 Issue 9, p2138 

    A spectroscopic plasma tomography measurement system has been developed and operated on a field-reversed configuration (FRC) plasma machine with the use of five photocollector arrays. Each photocollector array that is located azimuthally around the plasma column consists of ten optical fibers...

  • A pulsed microchannel-plate-based non-neutral plasma imaging system. Peurrung, A. J.; Fajans, J. // Review of Scientific Instruments;Jan1993, Vol. 64 Issue 1, p52 

    The design and operation of a pure electron plasma imaging system is described. The system yields images with high resolution and a large dynamic range. A two-dimensional image of the plasma is acquired by streaming the plasma directly onto a microchannel plate and phosphor screen. Resolution of...

  • Doppler coherence imaging and tomography of flows in tokamak plasmas (invited). Howard, J.; Diallo, A.; Creese, M.; Blackwell, B. D.; Allen, S. L.; Ellis, R. M.; Porter, G. D.; Meyer, W.; Fenstermacher, M. E.; Brooks, N. H.; Van Zeeland, M. E.; Boivin, R. L. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E528 

    This article describes the results of spatial heterodyne Doppler 'coherence imaging' of carbon ion flows in the divertor region of the DIII-D tokamak. Spatially encoded interferometric projections of doubly ionized carbon emission at 465 nm have been demodulated and tomographically inverted to...

  • Infrared thermography system on DIII-D. Petrie, T. W.; Hill, D. N.; Baptista, J.; Brown, M. // Review of Scientific Instruments;Nov90, Vol. 61 Issue 11, p3557 

    Six infrared cameras measure temperature changes on the protective graphite armor inside the DIII-D vacuum vessel. Simultaneous time-dependent temperature measurements are made on armor tiles located on the centerpost and divertor regions, and on both outboard limiters. The nearly complete...

  • Time resolved soft x-ray imaging with submicron spatial resolution (invited). Willi, O.; Afshar-rad, T.; Desselberger, M.; Dunne, M.; Edwards, J.; Khattak, F.; Taylor, R. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p4818 

    Recent progress in multilayered mirror technology has allowed the developments of novel imaging systems for probing of high density plasmas in the soft x-ray regime. The experimental system described here basically consists of a spherical multilayered mirror which reflects a narrow band (...5...

  • Soft x-ray tomography diagnostic at the RTP tokamak. da Cruz, D. F.; Donné, A. J. H. // Review of Scientific Instruments;Jul1994, Vol. 65 Issue 7, p2295 

    An 80-channel soft x-ray tomography system has been constructed for diagnosing the RTP (Rijnhuizen Tokamak Project) tokamak plasma. Five pinhole cameras, each with arrays of 16 detectors are distributed more or less homogeneously around a po1oidal plasma cross section. The cameras are positioned...

  • Laser-aided measurements of plasma transport (invited) (abstract). McWilliams, R.; Sheehan, D. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1536 

    Laser induced fluorescence (LIF) diagnostic techniques allow investigation of diverse plasma phenomena. LIF techniques will be discussed in the context of a series of experiments carried out at UCI including: (1) phase space reconstructions of ion response to electron and ion beam generated...

  • Tomography of m=1 mode structure in tokamak plasma using least-square-fitting method and Fourier–Bessel expansions. Nagayama, Yoshio // Journal of Applied Physics;10/1/1987, Vol. 62 Issue 7, p2702 

    Presents a study that examined the soft x-ray tomography of the m=1 magnetohydrodynamic mode structure in tokamak plasma using the least-square-fitting method and Fourier-Bessel expansions. Background on the measurement of radiation in plasma diagnostics; Details of the application of the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics