TITLE

Tunneling images of a high Tc superconducting Y1Ba2Cu3O7-x ceramic

AUTHOR(S)
Okoniewski, A. M.; Klemberg-Sapieha, J. E.; Yelon, A.
PUB. DATE
July 1988
SOURCE
Applied Physics Letters;7/11/1988, Vol. 53 Issue 2, p151
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Tunneling images of an Y1Ba2Cu3O7-x high Tc superconductor have been obtained in air. Slow scanning images show the roughness of surface in agreement with scanning electron microscope observations. Fast scanning pictures show the periodic structure with dimensions comparable to those of the bulk layered perovskite unit cell of the material.
ACCESSION #
9827326

 

Related Articles

  • ‘‘Oxide-free’’ tip for scanning tunneling microscopy. Colton, R. J.; Baker, S. M.; Baldeschwieler, J. D.; Kaiser, W. J. // Applied Physics Letters;8/3/1987, Vol. 51 Issue 5, p305 

    We report a new tip for scanning tunneling microscopy and a tip repair procedure that allows one to reproducibly obtain atomic images of highly oriented pyrolytic graphite with previously inoperable tips. The tips are shown to be relatively oxide-free and highly resistant to oxidation. The tips...

  • Scanning tunneling microscope induced nanostructuring of a Si(111)/Ag(...)R30... surface. Riehl-Chudoba, M.; Richter, Wo.; Gasparov, V. A. // Journal of Applied Physics;3/1/1998, Vol. 83 Issue 5, p2500 

    Presents information on the modification of the scanned tunneling microscope induced nanostructuring on silicon surface. How mesoscopic pits had been created; Increasing of the threshold voltage for pit formation; Performance of experiments; Information on surface modifications being induced.

  • Scanning tunneling microscope light emission spectroscopy with picosecond time resolution. Uehara, Y.; Yagami, A.; Ito, K. J.; Ushioda, S. // Applied Physics Letters;5/1/2000, Vol. 76 Issue 18 

    Scanning tunneling microscope (STM) light emission spectroscopy with picosecond time resolution has been developed and applied to the measurement of time-resolved spectra of STM light emission from an evaporated Au film. The spectra consist of two components in the time-energy domain. The first...

  • Possibility of observing magnetic macroscopic quantum tunneling using a scanning tunneling microscope. Molotkov, S. N. // Journal of Experimental & Theoretical Physics;Sep97, Vol. 85 Issue 3, p548 

    A theory describing the detection of magnetic macroscopic quantum tunneling on the basis of current fluctuations in a scanning tunneling microscope is proposed.

  • Adjustable nanofabricated atomic size contacts. van Ruitenbeek, J.M.; Alvarez, A.; Grahmann, C.; Joyez, P.; Devoret, M. H.; Esteve, D.; Urbina, C. // Review of Scientific Instruments;Jan1996, Vol. 67 Issue 1, p108 

    Describes the nanofabrication process for scanning tunneling microscopes. Observation of metallic point contacts and tunnel junctions with a small and adjustable number of conduction channels; Drift of the interelectrode spacing in the tunnel regime; Scaling down by two orders of magnitude of...

  • Microwave-frequency alternating current scanning tunneling microscopy by difference frequency detection: Atomic resolution imaging on graphite Schmidt, J.; Rapoport, D. H.; Rapoport, D.H.; Frohlich, H. J. // Review of Scientific Instruments;Aug1999, Vol. 70 Issue 8, p3377 

    Presents a detailed description of an experimental setup for alternating current scanning tunneling microscopy in which two slightly detuned high frequency signals are mixed at the tunneling junction. Amplification of the resulting difference frequency signal using conventional scanning...

  • Scanning tunneling microscope. Park, Sang-il; Quate, C. F. // Review of Scientific Instruments;Nov87, Vol. 58 Issue 11, p2010 

    This article describes the design of a scanning tunneling microscope (STM) which is suitable for surface science work. Various concepts in mechanical structure and electronic circuitry of the STM have been pursued to optimize its performance. This STM has been designed especially to meet the...

  • Anomalous distance dependence in scanning tunneling microscopy. Bryant, A.; Smith, D. P. E.; Binnig, G.; Harrison, W. A.; Quate, C. F. // Applied Physics Letters;10/13/1986, Vol. 49 Issue 15, p936 

    In this work it is found experimentally that the appearance of surfaces in scanning tunneling microscope (STM) images can change drastically as the distance between the STM tip and sample is varied. Defects are found on gold-sputtered graphite samples which appear as protrusions in charge...

  • Detection of phonons with a scanning tunneling microscope. Smith, Douglas P. E.; Binnig, Gerd; Quate, Calvin F. // Applied Physics Letters;12/15/1986, Vol. 49 Issue 24, p1641 

    A well defined spectrum of peaks in d2I/dV2 vs V has been obtained with a tunneling microscope immersed in liquid helium. The positions of the peaks correspond closely to the energies of the phonons of the graphite sample and the tungsten tip. We propose that electrons coupling to the bulk...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.