TITLE

Detection of individual 0.4–28 μm wavelength photons via impurity-impact ionization in a solid-state photomultiplier

AUTHOR(S)
Petroff, M. D.; Stapelbroek, M. G.; Kleinhans, W. A.
PUB. DATE
August 1987
SOURCE
Applied Physics Letters;8/10/1987, Vol. 51 Issue 6, p406
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A solid-state device capable of continuous detection of individual photons in the wavelength range from 0.4 to 28 μm is described. Operated with a dc applied bias, its response to the absorption of incident photons consists of submicrosecond rise time pulses with amplitudes well above the electronic readout noise level. A counting quantum efficiency of over 30% has been demonstrated at a wavelength of 20 μm, and over 50% was observed in the visible-light region. Optimum photon-counting performance occurs for temperatures between 6 and 10 K and for count rates less than 1010 counts/s per cm2 of detector area. The operating principle of the device is outlined and its performance characteristics as a photon detector are presented.
ACCESSION #
9823779

 

Related Articles

  • Real-time elimination of dead time and afterpulsing in counting systems. Finn, M. A.; Greenlees, G. W.; Hodapp, T. W.; Lewis, D. A. // Review of Scientific Instruments;Nov88, Vol. 59 Issue 11, p2457 

    A data taking scheme is described in which two photomultipliers record photons from a light source. It is shown that if the chain of recorded events is chosen to alternate between the two detectors, first-order effects of dead time and afterpulsing present in the two individual detectors are...

  • Photomultiplier characteristics and practice relevant to photon counting. Candy, B. H. // Review of Scientific Instruments;Feb1985, Vol. 56 Issue 2, p183 

    Certain nonideal photomultiplier characteristics are particularly relevant to the practice of photon counting. The literature on some of these characteristics can be rather confusing in the description of the mechanisms involved, such as those associated with single electron response distortion,...

  • Optimum amplification of microchannel-plate photomultiplier pulses for picosecond photon timing. Cova, S.; Ghioni, M.; Zappa, F. // Review of Scientific Instruments;Nov91, Vol. 62 Issue 11, p2596 

    Ultrafast microchannel-plate photomultipliers offer picosecond resolution in time-correlated photon counting, provided all additional causes of timing jitter be minimized. Here we analyze the contribution of the electronic circuit noise, mainly dependent on the fast preamplifier and no more...

  • Two-dimensional time-resolved imaging with 100-ps resolution using a resistive anode photomultiplier tube. Charbonneau, S.; Allard, L. B.; Young, Jeff F.; Dyck, G.; Kyle, B. J. // Review of Scientific Instruments;Nov92, Vol. 63 Issue 11, p5315 

    A two-dimensional microchannel plate photomultiplier with a position sensitive resistive anode has been integrated with time-correlated single photon counting circuitry. The result is a very powerful spectroscopic system which combines the very low dark count and parallel collection capabilities...

  • Minimization of discrimination jitter in time-correlated single photon counting. Anfinrud, Philip A.; Struve, Walter S. // Review of Scientific Instruments;Apr89, Vol. 60 Issue 4, p800 

    Instrument function widths in time-correlated single photon counting are minimized by adapting a commercial constant-fraction discriminator for essentially jitter-free processing of anode pulses from a Hamamatsu R1564U microchannel plate photomultiplier. This modification yields an instrument...

  • Improving the performance of ultrafast microchannel-plate photomultipliers in time-correlated photon counting by pulse pre-shaping. Cova, S.; Ripamonti, G. // Review of Scientific Instruments;Mar90, Vol. 61 Issue 3, p1072 

    With ultrafast microchannel-plate (MCP) photomultipliers that produce subnanosecond pulses, the commercially available circuit modules do not provide a correct constant-fraction trigger (CFT) operation. This has a detrimental effect on the resolution obtained in time-correlated photon counting...

  • NEW PRODUCTS. Rubin, Lawrence G. // Physics Today;Aug2001, Vol. 54 Issue 8, p57 

    Presents several photonics devices. Development of the R5509 photomultiplier tube; Introduction of the RH 1100 high-resolution triple-remote-head digital camera; Measurement of the wavelength of light through a silicon device.

  • Photon counting circuits. Candy, B. H. // Review of Scientific Instruments;Feb1985, Vol. 56 Issue 2, p194 

    Two photon counters with variable dead times are described, one of simple design which is suited for low count rates and the other for system dead times down to 2 ns. Cheap, well-known components are used and the counters were designed by computer aid with a criterion that circuit performance be...

  • Microsphere electron multiplier applicability to picosecond time correlated single photon counting. Rosenwaks, Y. // Review of Scientific Instruments;Jul97, Vol. 68 Issue 7, p2911 

    Focuses on the application of microsphere plate (MSP) electron multiplier to picosecond time correlated single photon counting. Reporting of electron transit-time spread (TTS) measurements; Differences between MSP and microchannel plate TTS; TTS of the MSP electron multiplier.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics