TITLE

Attainment of submillimeter periods and a 0.3-T peak field in a novel micropole undulator device

AUTHOR(S)
Tatchyn, Roman; Csonka, Paul L.
PUB. DATE
February 1987
SOURCE
Applied Physics Letters;2/16/1987, Vol. 50 Issue 7, p377
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A micropole undulator is defined here as an undulator with a very short (submillimeter) period and correspondingly shorter poles. The availability of micropole undulators is expected to profoundly affect the development of x-ray sources. For example, with such devices x-ray beams comparable to those from conventional undulators will be attainable on storage rings of much lower energy (and emittance) than those presently in use. X-ray instrumentation will also be affected, e.g., micropole undulators of sufficient length can provide extremely monochromatic outputs, obviating the need for expensive and complex ultrahigh vacuum monochromator systems. Here we describe the design and practical construction of a prototype 35 period micropole undulator whose total length is 2.54 cm. The device is of a novel hybrid/electromagnetic bias design. We also present results of field profile measurements along the central plane of the new device.
ACCESSION #
9822148

 

Related Articles

  • Attempt at LSI pattern demagnification by Bragg reflection. Nishino, J.; Morigami, M.; Harada, M.; Terakado, S.; Kobayashi, S.; Fujiwara, S.; Kaneda, K.; Goto, T.; Shimizu, R.; Suzuki, S.; Maezawa, H.; Ando, M. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p2153 

    A new method for pattern reduction in the x-ray region is proposed. In its principle was used the asymmetric Bragg reflection giving the different beamwidth in the reflected beam from the incident one. Light from an undulator line (BL-2) at the Photon Factory was used to obtain highly spatially...

  • Elliptical multipole wiggler facility at the Advanced Photon Source. Montano, P.A.; Knapp, G.S.; Jennings, G.; Gluskin, E.; Trakhtenberg, E.; Vasserman, I.B.; Ivanov, P.M.; Frachon, D.; Moog, E.R.; Turner, L.R.; Shenoy, G.K.; Bedzyk, M.J.; Ramanathan, M.; Beno, M.A.; Cowan, P.L. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1839 

    Presents a description of the elliptical multipole wiggler to be constructed at the Advanced Photon Source. Capability of the insertion device to produce circularly polarized x rays on axis; Frequency of the horizontal field change; Functions of each of the three stations that comprise the...

  • Emittance monitors based on Bragg-Fresnel lenses. Hartman, Ya.; Tarazona, E.; Elleaume, P.; Snigireva, I.; Snigirev, A. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1978 

    Presents the results of tests on two different setups for imaging an undulator source in the x-ray range. Single lens experiments; Combination of two circular Bragg-Fresnel lenses to form a high energy x-ray telescope; Magnification by an asymmetrically cut crystal.

  • A wire scanning type position monitor for an undulator radiation. Xiaowei Zhang; Sugiyama, Hiroshi; Ando, Masami; Shaojin Xia; Shiwaku, Hideaki // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1990 

    Describes the design and installation of a scanning wire position monitor for insertion devices in an x-ray undulator beam line. Principle of the monitor and its limitations; Signal level of the monitor; Components.

  • Cooling of silicon crystal monochromator for the undulator x rays at the beamline NE3. Mochizuki, Tetsuro; Xiaowei Zhang; Sugiyama, Hirosi; Jiyong Zhao; Ando, Masami; Yoda, Yositake // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p2167 

    Describes the design and installation of a double crystal monochromator accommodating water or liquid nitrogen cooling device for a first monochromator crystal in the x-ray undulator beamline NE3 of the TRISTAN accumulation ring. Silicon first crystal; Effect of the deformation of the rocking...

  • Field characteristics of novel hybrid undulators adequate to LCLS requirements. Simulation results. Varfolomeev, A. A.; Tolmachev, S. V. // AIP Conference Proceedings;2001, Vol. 581 Issue 1, p73 

    Magnetic field characteristics of two novel hybrid undulator schemes are given. The undulators were specially designed to be adequate to the X-ray FEL project LCLS. It is demonstrated that using these novel schemes the high specified magnetic field strengths can be obtained at larger gaps than...

  • The design and performance of an x-ray micro-focusing system using differentially deposited elliptical mirrors at the National Synchrotron Light Source. Ablett, J. M.; Kao, C. C.; Lunt, A. // Review of Scientific Instruments;Oct2002, Vol. 73 Issue 10, p3464 

    The National Synchrotron Light Source X13 straight section houses two insertion devices: a small-gap undulator (IVUN) and an elliptically polarized wiggler. The low vertical β function at the center of the straight section, where IVUN is located, produces an extremely small vertical source...

  • Microsecond Time-resolved Diffraction and Scattering Measurements System Using Semi-monochromatic X-ray Pulse at SPring-8 BL40XU. Oka, Toshiko; Onoue, Katsuaki; Yagi, Naoto; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p1197 

    SPring-8 BL40XU is designed to use high flux X-ray. On this basic concept, the fundamental radiation of the helical undulator is used as a semi-monochromatic X-ray beam. The flux at the experimental hutch is 1.0×1015 sec-1 at 12.4 KeV and the energy of X-ray width is about 1.8 %. Using the...

  • Correlation between measured undulator magnetic fields and x-ray spectraa). Carr, Roger; Kincaid, Brian; Hassenzahl, William // Review of Scientific Instruments;Jul1992, Vol. 63 Issue 7, p3564 

    Electron storage ring insertion devices, especially undulators, are designed using ideal device theory and the resulting x-ray spectra are reasonably close to predictions in most cases. However, magnetic field errors result in nonideal x-ray spectra. These effects can be calculated...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics