ABSTRACT
We describe an experimental method to detect and measure a thin air gap between an opaque film and a substrate. The method is pulsed photothermal radiometry with signal shape analysis at suitable delayed times. This relies on the use of a short light pulse to heat up the surface of the opaque film by∼10 °C, and detecting the infrared thermal emission from the surface as a function of time for a sufficiently long time. A numerical computation as well as an analytical approximation is developed to explain the dependence of the photothermal radiometry signal shape on the air gap thickness in the range of ten to hundreds of microns. Our work has applications not only for detecting subsurface air gaps and delaminations, but also for measuring the thermal resistance between layers for nondestructive characterization of adhesion bond strengths.
ACCESSION #
9821752

 

Related Articles

  • Application of modulated photothermal radiometry to infrared transparent samples. Walther, H. G.; Seidel, U.; Karpen, W.; Busse, G. // Review of Scientific Instruments;Nov92, Vol. 63 Issue 11, p5479 

    For the correct interpretation of modulated photothermal radiometric signals both the absorptive and IR-emmissive properties of the sample under test have to be taken into account. Therefore we derived a formula for layered samples and compared the theoretical predictions to measurements...

  • Multi-parameter-fitting procedure for photothermal infrared radiometry on multilayered and bulk-absorbing solids. Do¨rr, Peter; Gruss, Christian // Journal of Applied Physics;6/15/2001, Vol. 89 Issue 12, p7888 

    Photothermal infrared radiometry has been used for the measurement of thermophysical, optical, and geometrical properties of multilayered samples of paint on a metallic substrate. A special data normalization is applied to reduce the number of sensitive parameters which makes the identification...

  • Temperature measurement of fine wires by photothermal radiometry. Borca-Tasciuc, T.; Chen, G. // Review of Scientific Instruments;Nov97, Vol. 68 Issue 11, p4080 

    Reports on temperature measurement of fine wires using the photothermal radiometry (PTR) technique. Use of a laser to create a small periodic temperature perturbation on the wire; Small modulation of the thermal emission signal from the wire; Agreement with thermocouple readings at different...

  • Nondestructive evaluation of metal contaminated silicon wafers using radiometric measurements. Kalli, K.; Othonos, A. // Journal of Applied Physics;9/15/1999, Vol. 86 Issue 6, p3064 

    Presents information on a study which described nondestructive measurements on metal contaminated silicon wafers using photothermal radiometric measurements. Components of photothermal radiometry; Experimental results and discussion.

  • Nonlinear photothermal radiometrical material inspection technique. Wang, Chinhua; Li, Peizan // Journal of Applied Physics;11/1/1993, Vol. 74 Issue 9, p5713 

    Describes a technique called nonlinear photothermal radiometry that applies the second-harmonic thermal waves to material inspection and nondestructive evaluation. Implications of the measurement results of the second-harmonic signal; Description of the theoretical model developed; Differences...

  • Spectral dependence of signal distortions in spatially resolved photothermal radiometry. Paoloni, S.; Fournier, D. // Journal of Applied Physics;11/15/2002, Vol. 92 Issue 10, p5950 

    We consider a photothermal microscope based on spatially resolved IR radiometry to perform thermal diffusivity measurements. We analyze the influence of the detected IR wavelength range on the signal distortion arising from nonlinearity in the IR emission and diffYaction effects. These...

  • Simultaneous measurement of thermal diffusivity and optical absorption coefficient using photothermal radiometry. I. Homogeneous solids. Fuente, Raquel; Apiñaniz, Estibaliz; Mendioroz, Arantza; Salazar, Agustín // Journal of Applied Physics;Aug2011, Vol. 110 Issue 3, p033515 

    Modulated photothermal radiometry (PTR) has been widely used to measure the thermal diffusivity of bulk materials. The method is based on illuminating the sample with a plane light beam and measuring the infrared emission with an infrared detector. The amplitude and phase of the PTR voltage is...

  • Thermophotonic radar imaging: An emissivity-normalized modality with advantages over phase lock-in thermography. Tabatabaei, Nima; Mandelis, Andreas; Amaechi, Bennett T. // Applied Physics Letters;4/18/2011, Vol. 98 Issue 16, p163706 

    One major problem of frequency-domain photothermal radiometry, or alternatively in two-dimensional lock-in thermography, is the compromise one has to make between dynamic range (probing depth) and depth resolution. The thermal-wave radar incorporates chirped excitation through matched filtering...

  • Frequency domain photothermal radiometry with spherical solids. Wang, Chinhua; Liu, Yue; Mandelis, Andreas; Shen, Jun // Journal of Applied Physics;4/15/2007, Vol. 101 Issue 8, p083503 

    Motivated by increasing practical and industrial applications of photothermal techniques in the measurement of materials of various shapes with curvature, we extend the applications of photothermal diagnostics to solid spheres, in which both theoretical and experimental photothermal radiometry...