TITLE

Electron density measurements of electron beam pumped XeCl laser mixtures

AUTHOR(S)
Kimura, W. D.; Guyer, Dean R.; Moody, S. E.; Seamans, J. F.; Ford, D. H.
PUB. DATE
December 1986
SOURCE
Applied Physics Letters;12/8/1986, Vol. 49 Issue 23, p1569
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Time-dependent electron density measurements of electron beam pumped XeCl laser mixtures (nonlasing) are performed using a CO2 (10.6 μm) quadrature interferometer. The electron beam pulse length is ≊500 ns (full width at half-maximum) and delivers >=10 A/cm2 at the foil. Electron densities are measured as a function of the halogen (HCl) and xenon concentration. For a 99.3% Ne/1.5% Xe/0.16% HCl mixture at 3000 Torr, the electron density peaks near the beginning of the pulse at ≊7×1014 cm-3, decreases to 3×1014 cm-3, then gradually increases to ≊6×1014 cm-3 at the end of the pulse. As the initial halogen concentration is reduced, the electron density increases, rising dramatically near the end of the pulse. This increase in the electron density later in the pulse is accompanied by a decrease of the XeCl* sidelight fluorescence.
ACCESSION #
9821593

 

Related Articles

  • Photoelectric effects in x-ray preionization for excimer laser gases. Azarov, A. V.; Peters, P. J. M.; Boller, K.-J. // Journal of Applied Physics;Feb2008, Vol. 103 Issue 4, p043301 

    We present detailed measurements on the x-ray preionization electron density in a discharge chamber filled with different gases relevant to discharge pumped high-pressure excimer lasers. By comparing experimental results with the theoretical electron densities, we conclude that the observed...

  • Studies of excimer laser ablation of solids using a Michelson interferometer. Walkup, R. E.; Jasinski, J. M.; Dreyfus, R. W. // Applied Physics Letters;6/16/1986, Vol. 48 Issue 24, p1690 

    A Michelson interferometer has been used as a direct quantitative probe for gas phase plasma formation in the UV excimer laser ablation of solids. Excimer laser fluence thresholds for plasma formation are determined and correlated with optical emission from electronically excited ablation fragments.

  • Wavelength dependence of the excimer laser etching characteristics of a polymeric resist. Davis, G. M.; Gower, M. C. // Applied Physics Letters;5/4/1987, Vol. 50 Issue 18, p1286 

    The direct etching by excimer laser light of thin films of a polymeric resist, PMTM, has been studied at wavelengths of 157, 193, 222, and 248 nm. The energy absorbed per unit ablated volume near the etching threshold fluence indicates that a wavelength-dependent reaction mechanism causes...

  • Theory of polymer ablation. Mahan, G. D.; Cole, H. S.; Liu, Y. S.; Philipp, H. R. // Applied Physics Letters;12/12/1988, Vol. 53 Issue 24, p2377 

    A new formula is presented for the etch depth l per pulse of an excimer laser of fluence F. Incremental ablation is defined as the etch depth per pulse after many pulses. We show that l is proportional to F, rather than ln(F).

  • TEXT upgrade far-infrared interferometer system. Hallock, G. A.; Gartman, M. L.; Castles, R. L.; Chiang, K.; Rahman, A. S. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p2893 

    A high-resolution 2-D interferometer is being developed to measure electron density profiles in the TEXT-upgrade tokamak. Excellent port access allows both horizontal and vertical chords, which will be used to resolve plasma asymmetries. Close channel spacing is employed to give good spatial...

  • Determination of electron density in discharge-pumped excimer laser using Stark broadening of Hβ line. Hiramatsu, Mineo; Furuhashi, Hideo; Goto, Toshio // Journal of Applied Physics;9/15/1986, Vol. 60 Issue 6, p1946 

    Presents a study which determined the electron density in the discharge plasma used for the compact discharge-pumped rare-gas halide excimer laser of capacitor transfer type with automatic preionization. Principle of measurement applied for the study; Experimental setup; Results and discussion.

  • The effects of F2 concentration on discharge pumped KrF laser characteristics. Lou, Qihong; Yagi, Takashi; Igarashi, Kaoru; Saito, Hideaki // Journal of Applied Physics;9/15/1990, Vol. 68 Issue 6, p2572 

    Examines the fluorine concentration, laser output power, laser pulse duration and laser beam patterns of a discharge pumped krypton fluoride excimer laser. Effects of the fluoride concentration on the laser output characteristics; Near-field and far-field patterns of the excimer laser beam;...

  • Efficient high-homogeneous wide-aperture excimer discharge using a stabilizing low-current predischarge. Bychkov, Yu.; Kostyrya, I.; Makarov, M.; Suslov, A.; Yastremsky, A. // Review of Scientific Instruments;Apr94, Vol. 65 Issue 4, p793 

    A technique of initiation of a self-sustained electrical discharge for pumping excimer lasers, based on the use of a stabilizing predischarge with an electron density N[sub e]∼10[sup 12]-10[sup 13] cm[sup -3], has been developed. It has been demonstrated that such an auxiliary discharge is...

  • Ablated gratings on borosilicate glass by 193-nm excimer laser radiation. Pissadakis, S.; Reekie, L.; Hempstead, M.; Zervas, M.N.; Wilkinson, J.S. // Applied Physics A: Materials Science & Processing;1999, Vol. 69 Issue 7, pS739 

    Abstract. Relief gratings of 500-nm period have been fabricated on Er/Yb-doped borosilicate glass substrates by laser ablation through the use of an excimer laser, at a wavelength of 193-nm, and a modified Mach-Zehnder interferometer. The grating fabrication process has been quantified by the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.