Fast imaging of tokamak plasmas with integrated photodiode arrays

AUTHOR(S)
Castracane, J.; Demers, Y.
PUB. DATE
March 1986
SOURCE
Applied Physics Letters;3/17/1986, Vol. 48 Issue 11, p692
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Images with high temporal and spatial resolution of the resurrector tokamak plasma were obtained. The plasma cross section was focused onto a commercially available 128 pixel photodiode array (active area: 2.5×3.2 mm2). Specially designed data acquisition electronics allowed rapid readout for the observation of the spatial profile of visible emissions with 150 μs time resolution. The breakdown and subsequent evolution of the discharge was monitored to allow improvement of the plasma parameters.
ACCESSION #
9819298

 

Related Articles

  • Modeling of three-dimensional camera imaging in a tokamak torus Edmonds, P. H.; Medley, S.S. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p918 

    Describes a procedure for precision modeling of the views for imaging diagnostics monitoring tokamak internal components, particularly high heat flux divertor components. Measurement of image resolution and viewing incidence angle; Analytic calculation of resolution.

  • Spectroscopic imaging system for quantitative analysis of the divertor plasma of the Tokamak de... Meo, F.; Stansfield, B.L.; Chartre, M.; de Villers, P.; Marchand, R.; Ratel, G. // Review of Scientific Instruments;Sep97, Vol. 68 Issue 9, p3426 

    Discusses the development of a toroidally viewing spectroscopic imaging system for the Tokamak de Varennes. Measurements of the poloidal distribution of the absolute radiated power of deuterium and impurity species in the upper divertor region; Measurements of the divertor strike point and the...

  • First results from the phase contrast imaging system on TEXT-U Chatterjee, R.; Hallock, G. A. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p676 

    Describes the successful operation of a phase contrast imaging (PCI) diagnostic with a vertical beam covering the central third of the plasma to study density fluctuations in the TEXT-U tokamak. Optical design and layout; Tests and calibration of PCI.

  • Ion temperature and plasma rotation velocity measurements using visible spectroscopy on TdeV. Condrea, I.; Haddad, E.; Gregory, B.C.; Lafrance, D.; Lachambre, J.L.; Pacher, G.; Meo, F.; Mai, H.H. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p387 

    Describes the development of a visible spectroscopic imaging system on Tokamak de Varennes that provides profile measurements of the ion temperature and plasma rotation velocity. Experimental setup of the system; Spatial and spectral emission profiles provided by the charge-coupled device...

  • Electron cyclotron emission imaging diagnostic system for Rijnhuizen Tokamak Project. Deng, B.H.; Hsia, R.P.; Domier, C.W.; Burns, S.R.; Hillyer, T.R.; Luhmann Jr., N.C.; Oyevaar, T.; Donne, A.J.H. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p998 

    Describes the development of a 16-channel electron cyclotron emission (ECE) diagnostic system and its installation on the Rijnhuizen Tokamak Project for measuring plasma ECE. Achievement of high spatial resolution; Characteristics of the ECE imaging system sample volumes; Obtained wavenumber...

  • Data acquisition and processing system of the electron cyclotron emission imaging system of the KSTAR tokamak. Kim, J. B.; Lee, W.; Yun, G. S.; Park, H. K.; Domier, C. W.; Luhmann, N. C. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D931 

    A new innovative electron cyclotron emission imaging (ECEI) diagnostic system for the Korean Superconducting Tokamak Advanced Research (KSTAR) produces a large amount of data. The design of the data acquisition and processing system of the ECEI diagnostic system should consider covering the...

  • Commissioning of electron cyclotron emission imaging instrument on the DIII-D tokamak and first data. Tobias, B.; Domier, C. W.; Liang, T.; Kong, X.; Yu, L.; Yun, G. S.; Park, H. K.; Classen, I. G. J; Boom, J. E.; Donné, A. J. H.; Munsat, T.; Nazikian, R.; Van Zeeland, M.; Boivin, R. L.; Luhmann, N. C. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D928 

    A new electron cyclotron emission imaging diagnostic has been commissioned on the DIII-D tokamak. Dual detector arrays provide simultaneous two-dimensional images of Te fluctuations over radially distinct and reconfigurable regions, each with both vertical and radial zoom capability. A total of...

  • 2D electron cyclotron emission imaging at ASDEX Upgrade (invited). Classen, I. G. J.; Boom, J. E.; Suttrop, W.; Schmid, E.; Tobias, B.; Domier, C. W.; Luhmann, N. C.; Donné, A. J. H.; Jaspers, R. J. E.; de Vries, P. C.; Park, H. K.; Munsat, T.; García-Muñoz, M.; Schneider, P. A. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D929 

    The newly installed electron cyclotron emission imaging diagnostic on ASDEX Upgrade provides measurements of the 2D electron temperature dynamics with high spatial and temporal resolution. An overview of the technical and experimental properties of the system is presented. These properties are...

  • Simulation of a tangential soft x-ray imaging system. Battaglia, D. J.; Shafer, M. W.; Unterberg, E. A.; Bell, R. E.; Hillis, D. L.; LeBlanc, B. P.; Maingi, R.; Sabbagh, S.; Stratton, B. C. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E533 

    Tangentially viewing soft x-ray (SXR) cameras are capable of detecting nonaxisymmetric plasma structures in magnetically confined plasmas. They are particularly useful for studying stationary perturbations or phenomenon that occur on a timescale faster than the plasma rotation period. Tangential...