TITLE

Real time image subtraction and ‘‘exclusive or’’ operation using a self-pumped phase conjugate mirror

AUTHOR(S)
Kwong, Sze-Keung; Rakuljic, George A.; Yariv, Amnon
PUB. DATE
January 1986
SOURCE
Applied Physics Letters;1/20/1986, Vol. 48 Issue 3, p201
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Real time ‘‘exclusive or’’ operation with an interferometer using a self-pumped phase conjugate mirror is reported. Also, results of image subtraction and intensity inversion are shown.
ACCESSION #
9818922

 

Related Articles

  • Recirculation Fiber Loop Interferometer with a Faraday Reflector. Alekseev, É. I.; Bazarov, E. N.; Gubin, V. P.; Kovalenko, V. G.; Sazonov, A. I.; Starostin, N. I. // Technical Physics Letters;Nov2002, Vol. 28 Issue 11, p949 

    A new optical scheme of the recirculation fiber loop interferometer with a Faraday reflector and a broadband radiation source is suggested. It is experimentally established that this scheme provides for a more than tenfold decrease in the instrument zero response caused by a spurious...

  • Heterodyne detection of ultrasound from rough surfaces using a double phase conjugate mirror. Delaye, Philippe; Blouin, Alain // Applied Physics Letters;11/27/1995, Vol. 67 Issue 22, p3251 

    Presents an improved version of the classical heterodyne interferometer for ultrasound detection which includes a double phase conjugate mirror (DPCM). Performance of wave front adaptation to plane wave by DPCM; Example of application to the detection of laser generated ultrasound; Usefulness...

  • An interferometric device to measure the mechanical transfer function of the VIRGO mirrors suspensions Calloni, E.; Di Fiore, L.; Grado, A.; Milano, L. // Review of Scientific Instruments;Apr98, Vol. 69 Issue 4, p1882 

    Presents an interferometric device for measuring the mechanical transfer function of the VIRGO mirror suspensions. Operational principle; Design of servoloops for automating alignment and locking of gravitational wave detectors; Features of the device.

  • Negative dispersion mirrors for dispersion control in femtosecond lasers: chirped dielectric mirrors and multi-cavity Gires-Tournois interferometers. Szipöcs, R.; Köházi-Kis, A.; Lakó, S.; Apai, P.; Kovács, A.P.; DeBell, G.; Mott, L.; Louderback, A.W.; Tikhonravov, A.V.; Trubetskov, M.K. // Applied Physics B: Lasers & Optics;2000, Vol. 70 Issue 7, pS51 

    Abstract. Chirped dielectric laser mirrors have been known for years as useful devices for broadband feedback and dispersion control in femtosecond pulse lasers. First we present a novel design technique referred to as frequency domain synthesis of chirped mirrors. These mirrors exhibit high...

  • Measurement of the radius of curvature and decentering of the backings of laser mirrors on an interferometer computer profilometer. Vishnyakov, G.; Tselmina, I. // Measurement Techniques;Nov2012, Vol. 55 Issue 8, p904 

    A method of measuring the radius of curvature and the decentering of the backings of laser mirrors using the PIK-30 interferometer computer profilometer is considered.

  • Experimental demonstration of the use of a Fabry–Perot cavity as a mirror of variable reflectivity. Strain, K. A.; Hough, J. // Review of Scientific Instruments;Apr94, Vol. 65 Issue 4, p799 

    The use of a spherical mirror Fabry-Perot cavity as a mirror of variable reflectivity for near monochromatic light is demonstrated herein. The results of an experimental test of two control systems for the variable mirror are presented. It is shown that the reflectivity of our mirror can be...

  • Vibration Free Interferometer Mirror. Yaltkaya, S. // AIP Conference Proceedings;2007, Vol. 899 Issue 1, p689 

    Optic tables may be an obstacle for the interferometric studies when they are exposed to mechanical vibrations in the particular frequency range. To reduce the mechanical noise, a moveable mirror of the FTIR spectrometer was used as an interferometer mirror. The vibration response of this mirror...

  • Millimeter-wave phase-imaging interferometer for the GAMMA 10 tandem mirror. Hattori, K.; Mase, A.; Itakura, A.; Inutake, M.; Miyoshi, S.; Uehara, K.; Yonekura, T.; Nishimura, H.; Miyashita, K.; Mizuno, K. // Review of Scientific Instruments;Dec1991, Vol. 62 Issue 12, p2857 

    A millimeter-wave phase-imaging interferometer has been developed for the study of density profiles of the GAMMA 10 tandem mirror. The interferometer uses a 70-GHz klystron oscillator and a quasi-optical transmission system. The probe beam is expanded so as to fill an orthogonal view of a plasma...

  • ECE diagnostic for the TARA tandem mirror machine using a fast-scanning Michelson interferometer. Guharay, S. K.; Boyd, D. A.; Ellis, R. F. // Review of Scientific Instruments;Aug1986, Vol. 57 Issue 8, p1965 

    This ECE (electron cyclotron emission) diagnostic utilizes a fast-scanning Michelson interferometer to determine two parameters, the temperature and the loss cone angle, of the distribution function of the hot electrons (T ... 100 keV) generated in the axisymmetric plug plasma of the TARA tandem...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library