Hydrogen depth profiles in ion implanted magnetic bubble garnets

AUTHOR(S)
Leiberich, A.; Wolfe, R.
PUB. DATE
August 1985
SOURCE
Applied Physics Letters;8/1/1985, Vol. 47 Issue 3, p241
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The hydrogen depth profiles of ion implanted magnetic bubble garnet films have been measured by elastic recoil analysis using 44 MeV chlorine ions. The garnets were triply implanted with Ne, N, and H and were then annealed with or without a surface coating of SiO[sub 2]. At 250 °C, H was found to diffuse throughout the damaged surface layer but not into the underlying undamaged material. At 350 °C, H diffused out of the uncoated garnet, but was sealed into the implant damaged layer by the thin oxide coating. The deposition of the oxide layer at low temperature after implantation but before processing resulted in a constant H concentration profile extending throughout the implant damaged region of the bubble garnet. This retention of hydrogen correlates with previously reported improvements in propagation behavior of oxide coated ion implanted bubble devices.
ACCESSION #
9817943

 

Related Articles

  • Influence of deuterium implantation on bubble garnet properties. Gerard, P.; Capra, T.; Magnin, J. // Journal of Applied Physics;12/15/1985, Vol. 58 Issue 12, p4649 

    Discusses a study on the influence of deuterium implantation on bubble garnet properties. Nuclear techniques used to determine the implant and damage profiles; Significance of the control of ion implantation in the manufacture of bubble memories; Implantation conditions and as-implanted garnet...

  • Some hydrogen implantation effects in bubble garnets. Gerard, Ph.; Martin, P.; Delaye, M. T. // Journal of Applied Physics;4/15/1985, Vol. 57 Issue 8, p4058 

    Presents a study which tried to correlate the action of the hydrogen ion implant and the defect so produced on the magnetic properties of bubble garnets and their evolution upon annealing. Methodology; Results of the study; Conclusion.

  • Temperature dependence of 0.5-μm bubble propagation in ion-implanted devices. Jo, Soonchul; Kryder, M. H. // Journal of Applied Physics;4/15/1987, Vol. 61 Issue 8, p3488 

    Describes the temperature dependence of 0.5-μm bubble propagation in ion implanted propagation track fabricated with garnet films having nearly isotropic magnetorestriction. Propagation track cell size; Measurement of good and bad track bias margins of diamond and circular patterns; Margin...

  • Temperature and interface effects on the cubic anisotropy of ion-implanted bubble garnets. Maartense, I.; Searle, C. W. // Journal of Applied Physics;4/15/1985, Vol. 57 Issue 8, p4052 

    Presents a study which determined the temperature and interface effects on the cubic anisotropy of ion-implanted bubble garnets. Methodology; Reversibility-boundary curves for in-plane magnetization rotation in as-implanted films with the indicated dosages, measured at 20 degrees centigrade;...

  • Channeling effects on bubble propagation for 8-μm-period ion-implanted propagation patterns. Wen, Weiguang; Guan, Guixian; Chao, Xiangdong; Wei, Juan; Gao, Guowei; Wu, Zhenyuan; Lee, Zo-Yi // Journal of Applied Physics;4/15/1985, Vol. 57 Issue 8, p4049 

    Presents a study which examined the ion-implantation effects on magnetic bubble garnets. Methodology; Results of the study; Conclusion.

  • Variation of the temperature coefficient of collapse field in bismuth-based bubble garnets. Fratello, V. J.; Pierce, R. D.; Brandle, C. D. // Journal of Applied Physics;4/15/1985, Vol. 57 Issue 8, p4043 

    Presents a study which investigated the variation of the temperature coefficient of collapse field in bismuth-based bubble garnets. Methodology; Results of the study; Conclusions.

  • Formation and stability of small-size bubbles in garnet films. Ohkoshi, M. // Journal of Applied Physics;7/1/2002, Vol. 92 Issue 1, p370 

    Anomalous magnetic bubble domains have been detected in garnet films after chopping stripe domains with a high intensity pulsed field. These bubbles have smaller diameters than typically observed bubbles under low bias fields. These small-size bubbles remain stable within a narrow bias field...

  • Effects of helium ion double implantation on CD bubble device. Zhang, S. J.; Humphrey, F. B. // Journal of Applied Physics;4/15/1985, Vol. 57 Issue 8, p4046 

    Presents a study which examined the effects of helium ion double implantation on contiguous disk bubble devices. Methodology; Results of the study; Conclusion.

  • Magneto-optic measurements of the effects of crystalline anisotropy in ion-implanted layers of garnets. Fernandez-de-Castro, J. J.; Kryder, M. H. // Journal of Applied Physics;12/15/1991, Vol. 70 Issue 12, p7510 

    Describes a magneto-optic photometer system to characterize in-plane magnetization in ion-implanted magnetic bubble memory devices. Equations which describe the threefold symmetrical critical curve; Illustration of an ion-implanted contiguous disk device and laser beam path inside the magnetic...