TITLE

Magnetic structure for a microundulator

AUTHOR(S)
White, R. M.
PUB. DATE
January 1985
SOURCE
Applied Physics Letters;1/15/1985, Vol. 46 Issue 2, p194
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A scheme is proposed for the fabrication of an undulator having a magnetic period in the millimeter range.
ACCESSION #
9817037

 

Related Articles

  • Improvement of the pulsed wire method for undulator magnetic-field measurement. Park, K. H.; Jeong, S. H.; Kim, D. E.; Park, I. S.; Chung, C. W.; Kang, B. K. // Review of Scientific Instruments;Mar2002, Vol. 73 Issue 3, p1442 

    The U10 undulator for the Pohang Light Source was measured with a pulsed wire measurement (PWM) method. By adjusting the aperture of the slotted optical switch (SOS) for PWM, the sensitivity of SOS output to the wire displacement improved significantly. A calibration table, which translates the...

  • Undulator generating any kind of elliptically polarized radiation. Onuki, Hideo; Saito, Norio; Saito, Terubumi // Applied Physics Letters;1/18/1988, Vol. 52 Issue 3, p173 

    A new type of undulator with crossed and retarded magnetic fields which enables us to obtain any kind of elliptically polarized synchrotron radiation from relativistic electrons was developed. This undulator was installed in a straight section of the electron storage ring, TERAS, and its...

  • Invariance of Electromagnetic Radiation Spectra in Undulators Based on Plane Magnets. Smolyakov, M. N. // Technical Physics;Mar2000, Vol. 45 Issue 3, p356 

    Radiation of relativistic particles in a plane magnetic field (for example, in an undulator) is studied. The magnetic system is assumed to be plane and composed of permanent magnets. It is shown that there is a class of special continuous rotations of the magnetization vector for magnetic...

  • Polarizing undulator with crossed and retarded magnetic fields. Onuki, Hideo; Saito, Norio; Saito, Terubumi; Habu, Mitsuhiro // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1838 

    A prototype of the polarizing undulator with crossed and retarded magnetic fields which was able to produce any kind of elliptically polarized synchrotron radiation from relativistic electrons was designed and constructed. This undulator was installed in a straight section of the electron...

  • Spectral properties of segmented undulators for the 7-GeV Advanced Photon Source. Shenoy, G. K.; Viccaro, P. J.; Alp, E. E. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1820 

    The effect of nonzero particle beam emittance and magnetic field errors on the on-axis spectral brightness (BT[sub o]) of long undulators is discussed. It is shown that the quadratic dependence of B To on the number of undulator periods, N, is reduced by emittance to N[sup x] with 1 ≤ x <...

  • New multipole wiggler/undulator beamline (BL-16) at the Photon Factory. Matsushita, T.; Maezawa, H.; Ishikawa, T.; Nomura, M.; Nakagawa, A.; Mikuni, A.; Muramatsu, Y.; Satow, Y.; Kosuge, T.; Sato, S.; Koide, T.; Kanaya, N.; Asaoka, S.; Nagakura, I. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1874 

    Design and experience of the initial operation Of a new beamline (BL-16) for a 3.6-m-long, 53pole wiggler/undulator constructed at the Photon Factory are described. The insertion device has hybrid permanent magnets with a period of 12 cm and a maximum magnetic field of 1.47 T. In the undulator...

  • Magnetic field characterization, re-tuning and first operation of the NIST undulator on the Duke 1 GeV storage ring. Johnson, L. E.; Denbeaux, G.; Madey, J. M. J. // AIP Conference Proceedings;2000, Vol. 521 Issue 1, p358 

    Originally built for an IR FEL project at the National Institute of Standards and Technology, the NIST undulator was acquired by Duke for use as a soft x-ray source on the 1 GeV storage ring. The Brobeck Division of Maxwell Laboratories constructed this 3.64 m long hybrid-design undulator....

  • Linear theory of the collective Raman interaction in a free-electron laser with a planar wiggler and an axial guide field. Freund, H. P.; Davidson, R. C.; Johnston, G. L. // Physics of Fluids B: Plasma Physics;Feb90, Vol. 2 Issue 2, p427 

    A linear stability analysis of the collective Raman interaction in a free-electron laser with combined planar wiggler and axial guide magnetic fields is presented. The analysis involves a perturbation of the cold-fluid model of the interaction about the single-particle trajectories in the...

  • Orbit distortion due to UVSOR wiggler. Yonehara, H.; Kasuga, T.; Hasumoto, M.; Kinoshita, T. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1849 

    A three-pole wiggler with a maximum magnetic field of 4 T was installed in the UVSOR electron storage ring. The insertion effect on the tune and the closed orbit of the stored beam is not negligible. The measured tune shifts are in good agreement with the values estimated from results of the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library