TITLE

Electron velocity distributions measured with soft x-ray PHA at RTP

AUTHOR(S)
da Cruz, D. F.; Meijer, J. H.; Donné, A. J. H.
PUB. DATE
October 1992
SOURCE
Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p5026
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A soft x-ray pulse height analysis (PHA) system is begin used at the Rijhuizen Tokamak Project to study the electron velocity distribution. A liquid nitrogen cooled Si(Li) detector is used to view the plasma along a tangential line of sight. A gas cell in combination with A1 foils is used for filtering. The data-acquisition system is set up in such a way that 16 subsequent spectra, of 1ms-1 s duration and in the energy range 4-30 keV, can be measured during a single tokamak discharge. The PHA system has been used extensively for measuring the electron temperature, the effective charge number Z[sub eff], and the species and concentrations of high-Z impurities in the plasma. Special attention was devoted to study the effect on the electron velocity distribution of electron cyclotron resonance heating (ECRH) power (60 GHz, up to 180 kW) launched in the ordinary mode from the low-field side. During application of ECRH the temperature deduced from PHA always exceeds the value from Thomson scattering. This deviation can be explained by the presence of nonthermal components in the electron velocity distribution. Finally, the effect of boronization of the vacuum vessel on the impurity concentration was studied.
ACCESSION #
9786984

 

Related Articles

  • The JET soft x-ray diagnostic systems Alper, B.; Dillon, S.; Edwards, A. W.; Gill, R. D.; Robins, R.; Wilson, D. J. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p778 

    Describes the construction of a multicamera soft x-ray (SXR) detector system for the pumped divertor phase of the Joint European Torus tokamak to provide improved spatial and temporal resolution. Features of the SXR camera assemblies; Detector performance tests; Operational experience and...

  • Simulation of a tangential soft x-ray imaging system. Battaglia, D. J.; Shafer, M. W.; Unterberg, E. A.; Bell, R. E.; Hillis, D. L.; LeBlanc, B. P.; Maingi, R.; Sabbagh, S.; Stratton, B. C. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E533 

    Tangentially viewing soft x-ray (SXR) cameras are capable of detecting nonaxisymmetric plasma structures in magnetically confined plasmas. They are particularly useful for studying stationary perturbations or phenomenon that occur on a timescale faster than the plasma rotation period. Tangential...

  • Soft x-ray tomography diagnostic for the Alcator C tokamak. Camacho, J. F.; Granetz, R. S. // Review of Scientific Instruments;Mar86, Vol. 57 Issue 3, p417 

    A soft x-ray tomography diagnostic has been built and operated on the Alcator C tokamak with the use of an 80-channel array of detectors. The detector system consists of miniature PIN photodiodes which are located around the periphery of the plasma at one toroidal location (top and bottom ports)...

  • Toroidal and poloidal soft x-ray imaging system on the DIII-D tokamak. Snider, R. T.; Evanko, R.; Haskovec, J. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1807 

    A toroidal soft x-ray imaging system is being added to the currently installed poloidal soft x-ray system on the DIII-D tokamak. The poloidal array is used to determine the poloidal mode structure and location of internal helical MHD perturbations in the plasma. The new array will add toroidal...

  • Simultaneous soft x-ray emissivity profile measurements in poloidally separate locations of the Alcator C-Mod edge plasma. Sunn Pedersen, T.; Pedersen, T. Sunn; Granetz, R. S.; Granetz, R.S. // Review of Scientific Instruments;Sep2000, Vol. 71 Issue 9 

    Two high resolution edge x-ray imaging diagnostics have been installed in the Alcator C-Mod tokamak. One array measures the radial soft x-ray emissivity profiles at the top of the plasma with 1.2 mm radial resolution, mapped along flux surfaces to the midplane, whereas the other measures the...

  • A photodiode for the measurement of soft x-ray radiation from plasma. Qingjun Xiao; Navratil, Gerald // Review of Scientific Instruments;Sep96, Vol. 67 Issue 9, p3334 

    Reports on the use of photodiodes as detectors on the high beta tokamak-extended pulse tokamak for soft x-ray radiation measurement. Sawteeth instabilities and magnetohydrodynamic oscillations found in the signals from the photodiodes.

  • Soft x-ray tomography diagnostic at the RTP tokamak. da Cruz, D. F.; Donné, A. J. H. // Review of Scientific Instruments;Jul1994, Vol. 65 Issue 7, p2295 

    An 80-channel soft x-ray tomography system has been constructed for diagnosing the RTP (Rijnhuizen Tokamak Project) tokamak plasma. Five pinhole cameras, each with arrays of 16 detectors are distributed more or less homogeneously around a po1oidal plasma cross section. The cameras are positioned...

  • Diagnostics for local spectroscopic measurements in the divertor region of the Alcator C- Mod and DIII-D tokamaks May, M. J.; Regan, S. P.; Soukhanovskii, V. A.; Finkenthal, M.; Moos, H. W.; Goetz, J. A.; Lipschultz, B.; Terry, J. L.; West, P.; Allen, S.; Brooks, N. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p1047 

    Addresses the problems associated with extracting local signals of spectral line emissions from impurities in the divertor region of the tokamak and presents the design and implementation of the soft x-ray and extreme ultraviolet (XUV) Periscope. Spatial resolution of the XUV Periscope;...

  • Tomography of m=1 mode structure in tokamak plasma using least-square-fitting method and Fourier–Bessel expansions. Nagayama, Yoshio // Journal of Applied Physics;10/1/1987, Vol. 62 Issue 7, p2702 

    Presents a study that examined the soft x-ray tomography of the m=1 magnetohydrodynamic mode structure in tokamak plasma using the least-square-fitting method and Fourier-Bessel expansions. Background on the measurement of radiation in plasma diagnostics; Details of the application of the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics