TITLE

Time-resolved pinhole cameras for imaging multiterawatt Z pinches

AUTHOR(S)
Nash, T.; Deeney, C.; LePell, P. D.; Prasad, R.; Krishnan, M.
PUB. DATE
October 1990
SOURCE
Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p2807
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
X-ray pinhole images are formed on microchannel plate striplines to time-resolve Z-pinch emissions. Applications include a study of Z-pinch linearity necessary for x-ray lasers, the evolution of hot spots, and a study of Z-pinch heating mechanisms. In particular, multiple pinholes per strip with different filters allow the spatial and temporal variation of different temperature regions to be studied.
ACCESSION #
9786782

 

Related Articles

  • Time-resolved x-ray crystal spectrometer for multiterawatt Z-pinch spectroscopy. Nash, T.; Deeney, C.; LePell, P. D.; Prasad, R.; Krishnan, M. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p2804 

    A stripline gated microchannel plate framing camera is used as a detector in a crystal spectrometer. Typical 10 ns time gates are fast enough to record the evolution of both heating and expansion of Z pinches. By introducing spatially imaging cross slits, an x-ray spectrum from a Z pinch has...

  • Development of a visible framing camera diagnostic for the study of current initiation in z-pinch plasmas Muron, D. J.; Hurst, M. J.; Derzon, M. S. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p656 

    Describes a visible framing camera built to observe early time visible emission from z-pinch plasmas at the Saturn pulsed-power driven accelerator at Sandia National Laboratories in Albuquerque, New Mexico. Camera system; Optical system; Variation in sensitivity and gain characteristics from...

  • Measurements of axial nonuniformities in gas-puff implosions. Hsing, W. W.; Porter, J. L. // Applied Physics Letters;6/1/1987, Vol. 50 Issue 22, p1572 

    Large-scale-length axial nonuniformities in imploding z pinches have been measured with a time-resolved framing pinhole camera and a filtered x-ray diode. The nonuniform initial conditions of the annular gas column result in a nonsimultaneous stagnation along the pinch axis. By tailoring the...

  • High-fluence large-area MeV proton-beam diagnostics. Young, F. C.; Stephanakis, S. J.; Scherrer, V. E.; Mosher, D.; Richter, S. H. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p3122 

    The spatial distribution of intense MeV pulsed proton beams over 100 cm² area is measured with two techniques. An array of carbon-activation samples gives fluences of 100-400 J/cm² with 1-2 cm resolution. Continuous distributions with 3-4 mm resolution are obtained by imaging...

  • Thin Object Radiography with a 2.2 MeV Pulsed Power Machine. Haines, T. J.; Danielson, J. R.; Smit, J.; Wood, W. M. // AIP Conference Proceedings;2017, Vol. 1793 Issue 1, p1 

    An experimental series was performed at a pulsed-power 2.2 MeV flash radiography machine to determine the lower limits of its mass sensitivity. This machine uses a rod-pinch diode with accelerating potential of 2.2 MeV and 50 ns pulse duration. Tungsten, aluminium, and titanium rod anodes were...

  • Nested multilayered X pinches for generators with mega-ampere current level. Shelkovenko, T. A.; Pikuz, S. A.; McBride, R. D.; Knapp, P. F.; Wilhelm, H.; Hammer, D. A.; Sinars, D. B. // Physics of Plasmas;May2009, Vol. 16 Issue 5, p050702 

    A symmetric X pinch configuration that is conducive to using large numbers of wires on ≥1 MA pulsed power generators has been tested at 1 MA. Using an initial configuration of wires before their twisting, similar to nested cylindrical wire arrays, enables a geometrically simple, compact,...

  • Experimental measurement of spatially resolved electron density in a filament of a pulsed positive streamer discharge in water. Xiao Qiong Wen; Zhi Wen Niu; Bo Hou; Chun-Sheng Ren // Applied Physics Letters;7/1/2015, Vol. 106 Issue 26, p1 

    By combining a high-speed frame camera with a monochromator, the spatially resolved optical emission spectrum of hydrogen a line in a single filament of a pulsed positive streamer discharge in water has been experimentally measured. The spatially resolved electron densities in a single filament...

  • Neutron penumbral imaging at Gekko XII (abstract). Miyanaga, N.; Chen, Y.-W.; Unemoto, M.; Yamanaka, M.; Yamanaka, T.; Nakai, S.; Iida, T.; Iguchi, T.; Nakazawa, M. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p3230 

    14 MeV DT neutrons emitted from a laser-imploded target have been imaged by using a penumbral aperture camera. This system consists of a 6-cm-thick tungsten toroidal aperture, an array of plastic scintillators, an optical fiber coupled two-stage image intensifier, and a cooled CCD camera. A burn...

  • On-line tangential soft x-ray/VUV tomography on COMPASS-C. Durst, R. D. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p2750 

    A tangentially viewing pinhole camera has been used to image the COMPASS-C plasma in the vacuum ultraviolet and soft x-ray spectral regions with framing rates up to 330 Hz. The PC-based system acquires up to 256 128 × 128 pixel images per shot and incorporates an array processor to allow...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library