The Stark effect has been employed irt a novel technique for obtaining the pitch angle profile and q(r) using polarimetry measurements of the Doppler shifted H[sub α] emission from a hydrogen diagnostic neutral beam. As a neutral beam propagates through a plasma, collisions of the beam particles with the background ions and electrons will excite beam atoms, leading to emission of radiation. The motional Stark effect, which arises from the electric field induced in the atom's rest frame due to the beam motion across the magnetic field (E = V[sub beam] × B), causes a wavelength splitting of several angstroms and polarization of the emitted radiation. The Δm = ± 1 transitions, or σ components, from the beam fluorescence are linearly polarized parallel to the direction of the local magnetic field when viewed transverse to the fields. Since the hydrogen beam provides good spatial localization and penetration, the pitch angle can be obtained anywhere in the plasma. A photoelastic modulator (PEM) is used to modulate the linearly polarized light. Depending on the orientation of the PEM, it can measure the sine or cosine of the angle of polarization. Two PEM's are used to measure both components simultaneously. Results of q(r) for both Ohmic and NBI heated discharges have been obtained in the Princeton Beta Experiment (PBX-M) tokamak, with an uncertainty of ∼ 6% for q(0).
ACCESSION #
9786754

 

Related Articles

  • A high spatial resolution Stokes polarimeter for motional Stark effect imaging. Thorman, Alex; Michael, Clive; Howard, John // Review of Scientific Instruments;Jun2013, Vol. 84 Issue 6, p063507 

    We describe an enhanced temporally switched interfero-polarimeter that has been successfully deployed for high spatial resolution motional Stark effect imaging on the KSTAR superconducting tokamak. The system utilizes dual switching ferroelectric liquid crystal waveplates to image the full...

  • An Overview Of The Motional Stark Effect Diagnostic On DIII-D And Design Work For An ITER MSE. Holcomb, C. T.; Allen, S. L.; Makowski, M. A.; Jayakumar, R. J.; Gu, M. F.; Lerner, S.; Morris, K. L.; Latkowski, J.; Moller, J. M.; Meyer, W.; Ellis, R.; Geer, R.; Behne, D.; Chipman, R.; Smith, P.; McClain, S. // AIP Conference Proceedings;3/12/2008, Vol. 988 Issue 1, p214 

    The advanced tokamak research program at DIII-D relies critically on the measurement of the current density profile. This was made possible by the development of a Motional Stark Effect (MSE) polarimeter that was first installed in 1992. Three major upgrades have since occurred, and improvements...

  • Progress of neutral-beam-aided diagnostics on the HL-2A tokamak. Yu, D. L.; Wei, Y. L.; Liu, L.; Cao, J. Y.; Ma, Q.; Chen, W. J.; Liu, Y.; Yan, L. W.; Yang, Q. W.; Duan, X. R. // Review of Scientific Instruments;2014, Vol. 85 Issue 11, p1 

    A 32/64-channel Charge eXchange Recombination Spectroscopy (CXRS) and a 7-channel motional Stark effect (MSE) polarimeter have been developed on the HL-2A tokamak. To extract the maximum time resolution of the system, the incidence fibers of the spectrometer are pitch-controlled; and the...

  • On the Stark broadening of the 537.8 nm and 441.6 nm Cd[sup +] lines excited in a hollow cathode laser discharge. Csillag, L.; Dimitrijevic, M. S. // Applied Physics B: Lasers & Optics;Jan2004, Vol. 78 Issue 2, p221 

    On the basis of available experimental and theoretical data the role of the Stark effect in the homogeneous line broadening of the green and blue laser lines in a hollow cathode He-Cd[sup +] laser discharge is discussed. It is found, that at typical laser discharge parameters, for the 538 nm...

  • Simulation of the motional Stark effect diagnostic gas-filled torus calibration. Yuh, Howard Y.; Levinton, F. M.; Scott, S. D.; Ko, J. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10F523 

    Many motional Stark effect diagnostics around the world make use of a calibration procedure in which the observed neutral beam is injected into a gas-filled torus with known vacuum fields. The instrument is calibrated by reconciling measured angles with vacuum magnetic reconstructions through a...

  • Measurements of the internal magnetic field on DIII-D using intensity and spacing of the motional Stark multiplet. Pablant, N. A.; Burrell, K. H.; Groebner, R. J.; Kaplan, D. H.; Holcomb, C. T. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10F517 

    We describe a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of Stark split Dα emission from the neutral beams. This system, named B-Stark, has been recently installed on the DIII-D tokamak. To find the magnetic pitch angle, we use the...

  • Motional Stark effect diagnostic expansion on DIII-D for enhanced current and Er profile measurements. Holcomb, C. T.; Makowski, M. A.; Jayakumar, R. J.; Allen, S. A.; Ellis, R. M.; Geer, R.; Behne, D.; Morris, K. L.; Seppala, L. G.; Moller, J. M. // Review of Scientific Instruments;Oct2006, Vol. 77 Issue 10, p10E506 

    The motional Stark effect (MSE) diagnostic on DIII-D has been expanded to take advantage of a change in the neutral beam geometry, adding 24 new MSE channels viewing a beam injected counter to the plasma current. When data from these channels are used with those from two older MSE arrays viewing...

  • Transport with reversed shear in the National Spherical Torus Experiment. Levinton, F. M.; Yuh, H.; Bell, M. G.; Bell, R. E.; Delgado-Aparicio, L.; Finkenthal, M.; Fredrickson, E. D.; Gates, D. A.; Kaye, S. M.; LeBlanc, B. P.; Maingi, R.; Menard, J. E.; Mikkelsen, D.; Mueller, D.; Raman, R.; Rewoldt, G.; Sabbagh, S. A.; Stutman, D.; Tritz, K.; Wang, W. // Physics of Plasmas;May2007, Vol. 14 Issue 5, p056119 

    In the National Spherical Torus Experiment (NSTX) [M. Ono et al., Nucl. Fusion 40, 557 (2000)], plasmas with strongly reversed magnetic shear, s≡(r/q)(dq/dr)<0, in the plasma core exhibit a marked improvement in electron confinement compared to otherwise similar plasmas with positive or...

  • Motional Stark effect polarimetry for a current profile diagnostic in DIII-D (abstract). Wróblewski, D.; Burrell, K. H.; Lao, L. L.; Politzer, P.; West, W. P. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p2988 

    Motional Stark effect produces large net linear polarization of H[sub α] emission from neutral beams in tokamaks. Measurement of the polarization direction permits determination of the local magnetic field pitch angle. Design of a single point, spatially scannable, high-sensitivity...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics