TITLE

Code for time-resolved x-ray pulse analysis at high count rates for short tokamak discharges

AUTHOR(S)
Vega, J.
PUB. DATE
October 1990
SOURCE
Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p3268
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The measurement of soft x-ray spectrum in fusion plasmas allows for information on the nature of electron distribution, identification of impurity contents, calculation of electron temperature, estimation of Zeff, etc. All these measurements can be performed with a semiconductor detector. By amplifying the signal and using it as input to a multichannel analyzer (MCA), the spectrum is obtained. This kind of measurement does not have the desirable property of temporal resolution unless several detection chains are used or a special hardware is developed. In this paper, a method is presented to reach that type of resolution. This method requires only one measurement chain and the substitution of the MCA for a digitizer and mass storage. The digitized signal is stored in a computer, which will be the input for the several codes developed with the purpose of performing all the tasks of an MCA. These codes allow any number of time windows, of any length, along the digitized signal. Furthermore, in this way, it is possible to process one signal several times with different input parameters. Results in the TJ-I Tokamak (R[sub 0] = 0.3 m; a = 0.1 m; B[sub T] < 1.9 T; I[sub P] < 70 kA) are shown.
ACCESSION #
9786653

 

Related Articles

  • Simultaneous soft x-ray emissivity profile measurements in poloidally separate locations of the Alcator C-Mod edge plasma. Sunn Pedersen, T.; Pedersen, T. Sunn; Granetz, R. S.; Granetz, R.S. // Review of Scientific Instruments;Sep2000, Vol. 71 Issue 9 

    Two high resolution edge x-ray imaging diagnostics have been installed in the Alcator C-Mod tokamak. One array measures the radial soft x-ray emissivity profiles at the top of the plasma with 1.2 mm radial resolution, mapped along flux surfaces to the midplane, whereas the other measures the...

  • Extremely compact capillary discharge-based soft x-ray laser development and application to dense plasma diagnostics. Rocca, J. J.; Luther, B.; Marconi, M. C.; Whiteaker, T.; Braley, D. A.; Filevich, J.; Hammarsten, E. C.; Rahman, A.; Szapiro, B. T.; Wang, Y.; Jankowska, E.; Grisham, M.; Shlyaptsev, V. N.; Moon, S. // AIP Conference Proceedings;2002, Vol. 641 Issue 1, p125 

    We give an overview of recent capillary discharge-driven soft x-ray laser development experiments and applications ar Colorado State University. We report the demonstration of the first desktop size soft x-ray laser, a capillary discharge Ne-like Ar soft x-ray laser that was measured to emit...

  • New optical methods for short wavelength hot plasma diagnostics Kantsyrev, V.; Bruch, R. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p725 

    Describes the development of experimental methods for high-temperature plasma diagnostics based on both glass capillary converters (GCC) and multilayer mirrors. Pinhole chamber with GCC; GCC converters for investigations of time dependent plasma phenomena in the soft x-ray region; High...

  • Mode number identification with a soft x-ray array Kaita, R.; Sesnic, S. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p750 

    Describes a method using arrays of soft x-ray detectors for the determination of the toroidal and poloidal mode numbers of magnetohydrodynamic instabilities in tokamak plasmas. Toroidal mode number identification from maxima and minima in soft x-ray profiles; Phase difference observations in...

  • In situ calibration of microchannel-plate-based x-ray pinhole camera for observation of... Kikuchi, Y.; Kiwamoto, Y.; Takahashi, T.; Saito, T.; Tatematsu, Y.; Abe, H.; Kajiwara, K.; Yamaguchi, N.; Tamano, T. // Review of Scientific Instruments;Sep97, Vol. 68 Issue 9, p3421 

    Describes the in situ calibration of microchannel-plate (MCP)-based x-ray pinhole camera for observation of magnetically trapped plasma. Description of the experimental configuration and the structure of the pinhole camera system; Nonlinear response of the MCP; Correction of an observed...

  • Soft X-ray oscillations from AT Mic: Flare plasma diagnostics. Stepanov, A. V.; Tsap, Yu. T.; Kopylova, Yu. G. // Astronomy Letters;Aug2006, Vol. 32 Issue 8, p569 

    We consider the flare oscillations from the active red dwarf AT Mic detected with the XMM-Newton space observatory in the soft X-ray energy range (0.2–12 keV). Following Mitra-Kraev et al. (2005a), we associate the observed oscillations with a period of ≈750 s with the excitation of...

  • The SASE FEL at DESY: Photon Beam Diagnostics for the User Facility. Tiedtke, K.; Feldhaus, J.; Gerth, Ch.; Hahn, U.; Jastrow, U.; Ploenjes, E.; Steeg, B.; Treusch, R.; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p588 

    We present an overview of the vacuum-ultraviolet free electron laser (VUV FEL) user facility at DESY comprising the layout of the experimental hall, radiation transport to the experimental area, as well as photon beam diagnostics. In general, diagnostics of the FEL radiation is particularly...

  • Simulation of a tangential soft x-ray imaging system. Battaglia, D. J.; Shafer, M. W.; Unterberg, E. A.; Bell, R. E.; Hillis, D. L.; LeBlanc, B. P.; Maingi, R.; Sabbagh, S.; Stratton, B. C. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E533 

    Tangentially viewing soft x-ray (SXR) cameras are capable of detecting nonaxisymmetric plasma structures in magnetically confined plasmas. They are particularly useful for studying stationary perturbations or phenomenon that occur on a timescale faster than the plasma rotation period. Tangential...

  • A new double-foil soft x-ray array to measure Te on the MST reversed field pinch. McGarry, M. B.; Franz, P.; Den Hartog, D. J.; Goetz, J. A. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E516 

    A soft x-ray (SXR) diagnostic to measure electron temperature on the Madison Symmetric Torus using two complementary methods is presented. Both methods are based on the double-foil technique, which calculates electron temperature via the ratio of SXR bremsstrahlung emission from the plasma in...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics