TITLE

Ultrasensitive detection of hydrogen molecules by (2+1) resonance-enhanced multiphoton ionization

AUTHOR(S)
Vrakking, Marcus J. J.; Bracker, Allan S.; Suzuki, Toshinori; Lee, Yuan T.
PUB. DATE
March 1993
SOURCE
Review of Scientific Instruments;Mar93, Vol. 64 Issue 3, p645
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Ultrasensitive detection of molecular hydrogen is reported by using Doppler-free (2+1) resonance-enhanced multiphoton ionization through the E,F 1Σ+g state. By using an arrangement with two near-transform-limited counterpropagating laser beams, a single-shot detection efficiency of 6.8×103 molecules/cm3 has been demonstrated. Frequency scans of the two-photon transitions show that the detection efficiency is limited by ac Stark effects.
ACCESSION #
9785243

 

Related Articles

  • A laser beam analyzer for resonance ionization mass spectrometry studies. Thattey, S. S.; Thattey, S.S.; Suri, B. M.; Suri, B.M.; Bajaj, P. N.; Bajaj, P.N.; Dev, Vas // Review of Scientific Instruments;Jan2000, Vol. 71 Issue 1 

    We have developed a laser beam analyzer for quantitative studies in resonance ionization experiments. The laser beam profiles, which can be represented as images or as graphs, were used to compute the overlap of a number of laser beams interacting with an atom beam. In our experimental setup,...

  • Review of resonant laser ionization sources for on-line mass separators for radioactive ion beams... Mishin, V.I. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p934 

    Discusses the basic operation principles of laser ion sources (LIS) based on resonance ionization of atoms in a hot cavity. High elemental selectivity of the ionization process; Efficiency of single laser pulse ionization; Coupling of the LIS with a mass separator.

  • Versatile sample viewing system with large magnification range. Ocker, K. D.; Thonnard, N.; Joyner, C. F. // Review of Scientific Instruments;Feb2000, Vol. 71 Issue 2, p581 

    A sample viewing system has been designed and constructed to assist in the in situ analysis of terrestrial and extraterrestrial samples by laser microprobe gas extraction. The system provides sample viewing fields of 36 mm, 3.3 mm, and 370 μm, and combines and focuses the microprobing...

  • Measurement and modeling of nitrogen resonance line profiles from an electrodeless discharge lamp. Wood, David R.; Skinner, Gordon B.; Lifshitz, Assa // Journal of Chemical Physics;11/1/1987, Vol. 87 Issue 9, p5092 

    Experimental profiles of the 1200 Ã… resonance triplet of atomic nitrogen were measured for a variety of operating conditions of an end-on electrodeless lamp, and corresponding absorption curves were calculated. Each source profile was determined by fitting parameters to an empirical...

  • Resonance ionization spectroscopy. Hurst, G. Samuel; Letokhov, Vladilen S. // Physics Today;Oct94, Vol. 47 Issue 10, p38 

    Focuses on resonance ionization spectroscopy (RIS). Development of the laser-based spectroscopic technique to solve problems; Underlying principles; Measurement limits; Nuclear physics applications; Counting noble gas atoms; Thermal atomization; Practical application of RIS in materials science;...

  • Resonance Maximum in the System of Two K[sub S] Mesons at 1450 MeV. Vladimirsky, V. V.; Grigor’ev, V. K.; Erofeeva, O. N.; Katinov, Yu. V.; Lisin, V. I.; Luzin, V. N.; Nozdrachev, V. N.; Sokolovsky, V. V.; Tikhomirov, G. D.; Shkurenko, Yu. P. // Physics of Atomic Nuclei;Oct2001, Vol. 64 Issue 10, p1895 

    Reports on the investigation of the resonance of two meson systems based on experimental data from the spectrometer developed at the Institute of Theoretical and Experimental Physics in Moscow, Russia. Existence of resonance states revealed in the meson systems; Calculation of the effective...

  • Determination of trace amounts of plutonium in environmental samples by RIMS using a high repetition rate solid state laser system. Gru¨ning, C.; Huber, G.; Kratz, J. V.; Passler, G.; Trautmann, N.; Waldek, A.; Wendt, K. // AIP Conference Proceedings;2001, Vol. 584 Issue 1, p255 

    A reliable and easy to handle high repetition rate solid state laser system has been set up for routine applications of Resonance Ionization Mass Spectrometry (RIMS). It consists of three Titanium-Sapphire (Ti:Sa) lasers pumped by one Nd:YAG laser, providing up to 3 W of tunable laser light each...

  • Reduction of 1+1 resonance enhanced MPI spectra to populations and alignment factors. Jacobs, D. C.; Zare, R. N. // Journal of Chemical Physics;11/15/1986, Vol. 85 Issue 10, p5457 

    A theory is presented to reduce 1+1 resonance enhanced multiphoton ionization (REMPI) spectra to accurate rovibrational state population distributions. Classical and quantum mechanical treatments are developed to model the polarization dependence of the REMPI signal from an initially aligned...

  • Erratum: Observation of a new electronic state of C2 by resonance ionization spectroscopy [J. Chem. Phys. 88, 4548 (1988)]. Goodwin, Peter M.; Cool, Terrill A. // Journal of Chemical Physics;1/15/1989, Vol. 90 Issue 2, p1296 

    Presents a correction to the article 'Observation of a New Electronic State of C[sub2] by Resonance Ionization Spectroscopy,' which appeared in the 1988 issue of the 'Journal of Chemical Physics.'

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics