TITLE

A mass-selective neutral particle energy analyzer with background rejection

AUTHOR(S)
van Blokland, A. A. E.; Grimbergen, T. W. M.; van der Ven, H. W.
PUB. DATE
March 1992
SOURCE
Review of Scientific Instruments;Mar92, Vol. 63 Issue 3, p1978
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A mass-discriminating neutral particle spectrometer has been developed for the Rutherford scattering diagnostic at the TEXTOR tokamak. The analyzer is equipped with a momentum preselector and a triple-coincidence time-of-flight detection system providing a rejection capability for background events. Entering neutral particles are stripped by means of a thin carbon foil. Electrons emitted from a second carbon foil are used to give the time-zero signal. Calibration has been performed for hydrogen and helium particles in the energy range from 10 to 90 keV. The energy loss inside the carbon foils, the absolute efficiency, and the resolution of the analyzer have been investigated. The momentum preselector has a bandwidth of ±12.5% with respect to its adjustable central momentum. For both hydrogen and helium, the energy resolution is 2.5% for energies above 30 keV. Calculations show that the analyzer can still operate in the highly radiative environments of nuclear fusion devices.
ACCESSION #
9785191

 

Related Articles

  • Time of flight electron spectrometry on TIR using natural diamond detector. Krasilnikov, A. V.; Makarov, K. N.; Rastyagaev, I. N.; Satov, Yu. A.; Smakovskiy, Yu. B.; Alekseyev, A. G.; Amosov, V. N. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p1258 

    Natural diamond detectors (NDDs) being developed for the spectrometric applications in tokamak fusion plasma experiments, have been used also for fast x-ray flux measurements and time-of-flight (TOF) electron spectrometry in laser beam-target interaction experiments on the CO[sub 2] laser...

  • SPAM: A precision alignment device for spectrometer sightlines. Ramsey, A. T.; Bartolick, J. M. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p3250 

    As fusion devices become larger and their environments become harsher for instruments, diagnostics find themselves farther and farther away from the plasma. On TFTR, the UV survey spectrometer SPRED is over 9 m from the plasma. In these conditions, the alignment of the optical axis of the...

  • Tokamak fusion test reactor poloidal rotation diagnostic (invited). Bell, R.E.; Dudek, L.E.; Grek, B.; Johnson, D.W.; Palladino, R.W. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p821 

    Describes the development of a spectroscopic diagnostic to measure poloidal velocity profiles of Tokamak fusion test reactor plasmas. Measurement of the carbon poloidal velocities; Size of poloidal velocities; Statistical errors in the chord-averaged poloidal velocity; Features of the short...

  • A thin film device as a low energy, high flux charged particle spectrometer. Cecil, F. E.; Roy, Brian; Sutton, Christian; Wasinger, Nicole // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p792 

    We are continuing our investigation of the use of stacks of electrically isolated thin metal foils as spectrometers for lost ions from tokamak fusion plasmas. Devices of this type in which the foil thicknesses were a few micrometers were installed on the Joint European Torus during the recent...

  • Neutron spectrometry for plasma rotation Gorini, G.; Kallne, J.; Ballabio, L. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p561 

    Discusses the principles of neutron spectrometry for determination of the toroidal rotation velocity of the plasma in tokamaks. Principles of measurement; Comparisons with photon spectroscopy; Passive energy determination.

  • Measuring the escaping beam ions from a tokamak plasma. Buchenauer, D.; Heidbrink, W. W.; Roquemore, L.; McGuire, K. // Review of Scientific Instruments;Dec1987, Vol. 58 Issue 12, p2264 

    A new technique using a silicon surface barrier (SSB) diode has been developed for measuring the escaping fast ion flux from a tokamak plasma. Calibration of the detector with an ion beam showed that at a fixed energy the diode’s output current varied linearly with the incident deuteron...

  • Overview of Korea Superconducting Tokamak Advanced Research diagnostics Lee, S. G.; Lee, S.G.; Hwang, S. M.; Hwang, S.M.; Kim, B.C.; Lee, H. G.; Lee, H.G.; Na, H. K.; Na, H.K.; Yang, H. L.; Yang, H.L.; Yoo, S. J.; Yoo, S.J.; Medley, S.S.; Park, H. K.; Park, H.K.; Young, K. M.; Young, K.M. // Review of Scientific Instruments;Feb1999, Vol. 70 Issue 2, p1397 

    Provides an overview on the Korea Superconducting Tokamak Advanced Research (KSTAR) project for plasma diagnostics. Determination of plasma control, core plasma and divertor/edge plasma; Characteristics of the KSTAR diagnostics; Motional Stark effect system; Core Thomson scattering system;...

  • Plasma diagnostics for the CIT (invited). Medley, S. S.; Young, K. M.; CIT Diagnostics Team // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1745 

    The primary mission of the Compact Ignition Tokamak (CIT) is to study the physics of alphaparticle heating in an ignited D-T plasma. A burn time of about 10Ï„[sub E] is projected in a divertor configuration with base-line machine design parameters of R = 2.10 m, a = 0.65 m, b = 1.30 m, I[sub...

  • Vertical-viewing electron cyclotron emission diagnostic for the DIII-D tokamak. James, Reed; Janz, S.; Ellis, R.; Boyd, D.; Lohr, John // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1611 

    The vertical-viewing electron cyclotron emission diagnostic on DIII-D will be used to assess the nonthermal electron distributions resulting from electron cyclotron heating and electron cyclotron current drive experiments. Electron cyclotron emission along a vertical chord is collected using an...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics