TITLE

Use of simultaneous reflections for precise absolute energy calibration of x rays

AUTHOR(S)
Arthur, J.
PUB. DATE
July 1989
SOURCE
Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p2062
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
An experimental study of intensity variations in a synchrotron x-ray beam caused by the presence of simultaneous reflections in the silicon monochromator crystals has been compared with calculations based on dynamical diffraction theory in an effort to determine the practical limits to the use of such intensity variations for energy calibration. It has been found that relative misalignments of the monochromator crystals can lead to errors of approximately 0.01% ( 1 eV at 10 keV ), but that with some care energy calibration to within 0.002 % (0.2 eV at 10 keV ) can be achieved in a short measurement.
ACCESSION #
9784030

 

Related Articles

  • Thermal bilayer monochromator crystal for a high resolution multiwavelength anomalous diffraction... Ferrer, Jean-Luc; Roth, Michael; Fanchon, Eric; Poupon, Gilles; Saint-Lager, Marie-Claire; Berar, J.-F. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p2089 

    Describes a thermal bilayer monochromator crystal for a high resolution multiwavelength anomalous diffraction beamline at the European Synchrotron Radiation Facility in Grenoble, France. Theoretical aspects of the monochromator crystal; Manufacture of the bilayer; Manufacture of the cooling...

  • Application of an imaging plate to high-pressure x-ray study with a diamond anvil cell (invited). Shimomura, O.; Takemura, K.; Fujihisa, H.; Fujii, Y.; Ohishi, Y.; Kikegawa, T.; Amemiya, Y.; Matsushita, T. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p967 

    In order to obtain reliable data on d values and integrated intensities, an imaging plate (IP) has been applied to high-pressure diffraction experiments with a diamond anvil cell using synchrotron radiation. The IP was found to be more effective than a conventional x-ray film by a factor of 30,...

  • Design of a miniature hydraulic compression load frame for microdiffraction tests at the advanced photon source. Shu, Deming; Verma, Ravi; Krasnicki, Szczesny; Sinha, Sunil // AIP Conference Proceedings;2000, Vol. 521 Issue 1, p198 

    In support of the x-ray synchrotron radiation microdiffraction project of Los Alamos National Laboratory at the Advanced Photon Source (APS), we have designed and fabricated a miniature hydraulic compression load frame with 20000 N load capacity for metal specimen tests at the APS. The compact...

  • Diffraction of high-energy synchrotron radiation (invited) (abstract). Bruckel, Th.; Bouchard, R.; Kohler, T.; Lippert, M.; Neumann, H.-B.; Poulsen, H.F.; Rutt, U.; Schmidt, T.; Schneider, J.R.; von Zimmermann, M. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1614 

    Presents an abstract of a paper describing the diffraction of high-energy synchrotron radiation at energies above 100 keV. Absorption in matter for hard x rays; Demonstration of the potential of the method in magnetic diffraction from MnF[sub 2] and the structural phase transition of SrTiO[sub 3].

  • W16.1: A new fixed wavelength diffraction station at the SRS Daresbury. Bliss, N.; Bordas, J.; Fell, B.D.; Harris, N.W.; Helsby, W.I.; Mant, G.R.; Smith, W.; Towns-Andrews, E. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1311 

    Describes the key features of a fixed wavelength diffraction station constructed and commissioned at the Synchrotron Radiation Source Daresbury Laboratory in Great Britain. Kratky mechanism; Monochromator; Mirror; Experimental station; Data acquisition.

  • Construction of the multilayered-mirror monochromator beam line for the study of synchrotron... Mekaru, Harutaka; Tsusaka, Yoshiyuki; Miyamae, Takayuki; Kinoshita, Toyohiko; Urisu, Tsuneo; Masui, Shin; Toyota, Eijiro; Takenaka, Hisataka // Review of Scientific Instruments;Jun99, Vol. 70 Issue 6, p2601 

    Describes the construction of a multilayered-mirror monochromator beam line designed specially for synchrotron radiation stimulated process experiments. Criteria used in the design of the beam line; Performance of the monochromator.

  • Performance of a wideband multilayer polarizer for soft x rays. Yanagihara, Mihiro; Maehara, Takumi; Nomura, Hiroshi; Yamamoto, Masaki; Namioka, Takeshi; Kimura, Hiroaki // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1516 

    Performance of a Ru/C multilayer polarizer of double-crystal x-ray monochromator type has been evaluated in the soft x-ray region using synchrotron radiation. The throughput efficiencies for s-polarized light were found to be 11.5% at 100 eV and higher than 4% over an energy range of 80-450 eV...

  • High resolution monochromatic tomography with x-ray sensing pickup tube. Hirano, Tatsumi; Usami, Katsuhisa; Sakamoto, Kozoo // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p2482 

    Using monochromatic synchrotron radiation and a high resolution x-ray sensing pickup tube as a two-dimensional detector, we have improved the spatial resolution of x-ray computed tomographic (CT) images. A quantitative elemental analysis was made based on the difference between two CT images...

  • Monochromator and beamline for a laboratory synchrotron (abstract). Tiit, V.; Kuznetsov, A. S.; Pill, K.; Vilt, E. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p2132 