TITLE

Time-resolved temperature measurement of a pinched plasma using the dispersive x-ray analysis of the continuum emission

AUTHOR(S)
Venneri, F.; Gerdin, G.
PUB. DATE
December 1990
SOURCE
Review of Scientific Instruments;Dec1990, Vol. 61 Issue 12, p3797
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The dispersive analysis of the x-ray continuum is employed to determine the electron temperature of a dense pinched plasma. A curved crystal spectrometer was used to obtain the desired dispersion, and two or more p-i-n (doubly diffused silicon) diodes were used to monitor the time-resolved emission. The dispersive technique is inherently more accurate than filtering techniques and simpler to implement than laser scattering techniques. In an experimental verification of the technique, the time-resolved temperature of a plasma focus pinch was measured under various conditions, and was found to be consistent with density observations and MHD calculations. It was possible to observe the cooling effect of radiation emission from seeded plasma focus discharges. The elliptical crystal spectrometer is shown to be well suited to the analysis of the x-ray emission from a pinched plasma source.
ACCESSION #
9782114

 

Related Articles

  • Enhanced damping of ion acoustic waves in dense plasmas. Son, S.; Moon, Sung Joon // Physics of Plasmas;Jan2011, Vol. 18 Issue 1, p014505 

    A theory for the ion-acoustic wave damping in dense plasmas and warm dense matter, accounting for the Umklapp process, is presented. A higher decay rate compared to the prediction from the Landau damping theory is predicted for high-Z dense plasmas, where the electron density ranges from 1021 to...

  • A Simple Method For The Time-Resolved Measurement Of Electron Temperature In A Z-pinch. Robledo-Martinez, Arturo // AIP Conference Proceedings;2006, Vol. 875 Issue 1, p27 

    A new method for measuring the electron temperature in a Z-pinch plasma with time resolution is presented here. PIN diodes fitted with different filters were employed to detect the X-radiation in separate energy bands. By comparison of the relative intensities of the X-ray pulses, a...

  • Performance of a permanent-magnet helicon source at 27 and 13 MHz. Chen, Francis F. // Physics of Plasmas;Sep2012, Vol. 19 Issue 9, p093509 

    A small helicon source is used to create dense plasma and inject it into a large chamber. A permanent magnet is used for the dc magnetic field (B-field), making the system very simple and compact. Though theory predicts that better antenna coupling will occur at 27.12 MHz, it was found that...

  • Wave and transport studies utilizing dense plasma filaments generated with a lanthanum hexaboride cathode. Van Compernolle, B.; Gekelman, W.; Pribyl, P.; Cooper, C. M. // Physics of Plasmas;Dec2011, Vol. 18 Issue 12, p123501 

    A portable lanthanum hexaboride (LaB6) cathode has been developed for use in the LArge Plasma Device (LAPD) at UCLA. The LaB6 cathode can be used as a tool for many different studies in experimental plasma physics. To date, the cathode has been used as a source of a plasma with a hot dense core...

  • Use of a double-Wollaston prism laser differential interferometer in a plasma focus. Ming Fang Lu // Review of Scientific Instruments;Feb1997, Vol. 68 Issue 2, p1149 

    Details the use of a double-Wollaston prism laser differential interferometer in observing the evolution of the imploding current sheath and the high temperature in the plasma focus. Background on the principle of the differential interferometry; Measurement of the density gradients and line...

  • The Naval Research Laboratory Modified Betatron Accelerator and assessment of its results[ATOTHER]@f|[/ATOTHER]. Kapetanakos, C. A.; Len, L. K.; Smith, T.; Marsh, S. J.; Loschialpo, P.; Dialetis, D.; Mathew, J. // Physics of Fluids B: Plasma Physics;Jul93, Vol. 5 Issue 7, p2295 

    In this paper the experimental results of the Naval Research Laboratory (NRL) Modified Betatron Accelerator (MBA) [Phys. Rev. Lett. 64, 2374 (1990)] are briefly summarized and assessed. These results show that the addition of the strong focusing (SF) field made a substantial improvement in the...

  • EUV lithography.  // Solid State Technology;Feb2002, Vol. 45 Issue 2, p43 

    Focuses on dense plasma focus (DPF) devices as sources for extreme ultraviolet (EUV) lithography. Overview of EUV source requirements; Principles in the operation of DPF; Measurements of the energy stability for EUV lithography; Size of the EUV source.

  • X-pinch soft x-ray source for microlithography. Hammer, D. A.; Kalantar, D. H.; Mittal, K. C.; Qi, N. // Applied Physics Letters;11/12/1990, Vol. 57 Issue 20, p2083 

    A novel soft x-ray source for submicron resolution lithography is described. Exploratory experiments with the x-pinch dense plasma radiation source have been performed using a 500 kA, 40 ns pulsed power generator. About 33 J of magnesium K-shell radiation (1.3–1.5 keV) and 10 J of...

  • Breeding 10[sup 10]/s radioactive nuclei in a compact plasma focus device. Brzosko, Jan S.; Melzacki, Krzysztof; Powell, Charles; Gai, Moshe; France, Ralph H.; McDonald, James E.; Alton, Gerald D.; Bertrand, Fred E.; Beene, James R. // AIP Conference Proceedings;2001, Vol. 576 Issue 1, p277 

    In the early 90's, it was discovered that a Plasma Focus (PF) system self-creates a plasma-target in which high energy-threshold nuclear-reactions occur at high reaction rates. Short life radioisotopes (SLR)s such as [sup 18]F, [sup 17]F, [sup 15]O, [sup 14]O, [sup 13]N have been generated...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics