TITLE

Plasma diagnostics for the CIT (invited)

AUTHOR(S)
Medley, S. S.; Young, K. M.; CIT Diagnostics Team
PUB. DATE
August 1988
SOURCE
Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1745
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The primary mission of the Compact Ignition Tokamak (CIT) is to study the physics of alphaparticle heating in an ignited D-T plasma. A burn time of about 10τ[sub E] is projected in a divertor configuration with base-line machine design parameters of R = 2.10 m, a = 0.65 m, b = 1.30 m, I[sub P] = 11 MA, B[sub T] = 10 T, and 10-20 MW of auxiliary rf heating. Plasma temperatures and density are expected to reach T[sub e] (0) ∼ 20 keV, T[sub i] (0) ∼ 30 keV, and n[sub e] (0) ∼ 1 × 10[sup 21] m[sup -3]. The combined effects of restricted port access to the plasma, the presence of severe neutron and gamma radiation backgrounds, and the necessity for remote handling of in-cell components create challenging design problems for ail of the conventional diagnostics associated with tokamak operations. In addition, new techniques must be developed to diagnose the evolution in space, time, and energy of the confined alpha distribution as well as potential plasma instabilities driven by collective alpha-particle effects. The design effort for CIT diagnostics is presently in the conceptual phase, with activity being focused on the selection ora viable diagnostic set and the identification of essential research and development projects to support this process. A review of these design issues and other aspects impacting the selection of diagnostic techniques for the CIT experiment will be presented.
ACCESSION #
9781519

 

Related Articles

  • Measuring the escaping beam ions from a tokamak plasma. Buchenauer, D.; Heidbrink, W. W.; Roquemore, L.; McGuire, K. // Review of Scientific Instruments;Dec1987, Vol. 58 Issue 12, p2264 

    A new technique using a silicon surface barrier (SSB) diode has been developed for measuring the escaping fast ion flux from a tokamak plasma. Calibration of the detector with an ion beam showed that at a fixed energy the diode’s output current varied linearly with the incident deuteron...

  • Overview of Korea Superconducting Tokamak Advanced Research diagnostics Lee, S. G.; Lee, S.G.; Hwang, S. M.; Hwang, S.M.; Kim, B.C.; Lee, H. G.; Lee, H.G.; Na, H. K.; Na, H.K.; Yang, H. L.; Yang, H.L.; Yoo, S. J.; Yoo, S.J.; Medley, S.S.; Park, H. K.; Park, H.K.; Young, K. M.; Young, K.M. // Review of Scientific Instruments;Feb1999, Vol. 70 Issue 2, p1397 

    Provides an overview on the Korea Superconducting Tokamak Advanced Research (KSTAR) project for plasma diagnostics. Determination of plasma control, core plasma and divertor/edge plasma; Characteristics of the KSTAR diagnostics; Motional Stark effect system; Core Thomson scattering system;...

  • Feasibility of neutron spectrometry diagnostic for the fuel ion density in DT tokamak plasmas Kallne, J.; Gorini, G.; Ballabio, L. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p581 

    Examines the effect of the neutron wall emission background on the diagnostic quality of the fuel density determination in neutron spectrometry of deuterium-tritium fusion plasmas in tokamaks. Diagnostic principle and signal strength; Description of the wall emission background; Error effects...

  • A tangentially viewing visible TV system for the DIII-D divertor Fenstermacher, M. E.; Meyer, W. H.; Wood, R. D.; Nilson, D. G.; Ellis, R.; Brooks, N. H. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p974 

    Describes the installation of a video camera system on the DIII-D tokamak for two-dimensional spatial studies of line emission in the lower divertor region. Hardware; Image analysis software; Three-dimensional image data.

  • Vertical-viewing electron cyclotron emission diagnostic for the DIII-D tokamak. James, Reed; Janz, S.; Ellis, R.; Boyd, D.; Lohr, John // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1611 

    The vertical-viewing electron cyclotron emission diagnostic on DIII-D will be used to assess the nonthermal electron distributions resulting from electron cyclotron heating and electron cyclotron current drive experiments. Electron cyclotron emission along a vertical chord is collected using an...

  • Simple ion temperature diagnostics for a short tokamak discharge. Zurro, B.; García-Castañer, B.; Hidalgo, C.; Pérez, S.; Pallás, L. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1509 

    A simple experimental procedure used in the TJ-I tokamak, for simultaneously measuring the ion temperature is described. Two monochannel systems (neutral and optical) are scanned at a preprogrammed time of the tokamak discharge, where the signals are stationary. System performances are...

  • Observations of radial wild cables in tokamak plasmas (abstract). Kukushkin, A. B.; Rantsev-Kartinov, V. A. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p506 

    The results of processing the plasma images with the help of the method of multilevel dynamical contrasting (MDC)1 are presented. The images are taken in visible light, with space resolution ∼100 μm and time resolution ∼10 μs, in various tokamaks (TM-2, T-4, T-6, and T-10). The...

  • Magnetic diagnostics for Korea superconducting tokamak advanced research. Lee, S. G.; Bak, J. G. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p439 

    Magnetic diagnostics are essential tools for operation and control of the Korea Superconducting Tokamak Advanced Research (KSTAR) device and for understanding the plasma behavior. For this purpose, a concept and preliminary engineering design for the KSTAR magnetic diagnostics have been...

  • Performance test of sample coils in the Korea superconducting tokamak advanced research magnetic diagnostics test chamber. Bak, J. G.; Lee, S. G. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p435 

    Most of the Korea Superconducting Tokamak Advanced Research (KSTAR) magnetic diagnostics (MDs) are proposed to be installed inside of the vacuum vessel which is baked out up to 250 °C, and whose base pressure will be ∼5×10[sup -9] Torr. Therefore, MDs must be compatible with the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library