TITLE

The preliminary experiments on laser ion source at IMP

AUTHOR(S)
Ping, Yuan; Sixing, Zhou; Baowen, Wei
PUB. DATE
April 1994
SOURCE
Review of Scientific Instruments;Apr94, Vol. 65 Issue 4, p1275
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The experimental results of a study on a laser ion source are presented in this report. A gain of about five in the total peak current and an enhanced relative amount of higher charge states were observed when the laser-generated plasma was transported through magnetic bottle fields. Radio-frequency discharge was added to the laser ion source, further ionizing the primary laser plasma. In this case, the total peak current increased from 0.46 to 1.4 mA. It is suggested that the laser plasma can be used in an electron cyclotron resonance source to produce ions of solid elements.
ACCESSION #
9781038

 

Related Articles

  • Discharge characteristics and H--ion production in a bucket ion source. Kosaka, T.; Yamashita, H.; Miyamoto, S.; Inoue, S.; Horiike, H. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p961 

    The cusp leak was found to have a profile of multiple peaks, when measured near the filaments. This is attributable to multiple discharge paths of primary electrons. The supercusp magnetic configuration is one of several configurations in which strong magnetic-field lines flow into the backplate...

  • Construction and study of a magnetoactive plasma ion source. Krasnogolovets, M. A. // Technical Physics;Apr99, Vol. 44 Issue 4, p390 

    The interaction of intense electron beams with plasmas in a nonuniform magnetic field is studied for the purpose of obtaining a magnetoactive plasma ion source. The resulting experimental data are used to trace the dynamics of the changes in the basic parameters of the source, both during the...

  • Effects of internal and external magnetic fields on the characteristics of a magnetic multipole plasma source. Tanaka, Shigeru; Akiba, Masato; Horiike, Hiroshi; Matsuoka, Mamoru; Ohara, Yoshihiro; Okumura, Yoshikazu // Review of Scientific Instruments;Feb1986, Vol. 57 Issue 2, p145 

    Influences of an externally produced axial magnetic field and the field produced by the filament current on the performance of a magnetic multipole plasma source were experimentally studied using a high-proton-yield ion source developed for the JT-60 NBI. It was shown that both of the fields...

  • Vacuum arc trigger systems based on ExB discharges. Nikolaev, A.G.; Yushkov, G. Yu.; Oks, E.M.; MacGill, R.A.; Dickinson, M.R.; Brown, I.G. // Review of Scientific Instruments;Sep96, Vol. 67 Issue 9, p3095 

    Reports on the development of triggering systems for vacuum arc plasma sources and ion sources that make use of a gaseous trigger discharge in a strong magnetic field. Exploration of two kinds of trigger discharge; Reliability of the approach for low gas pressure in the vacuum arc environment.

  • Characteristics of a sheet plasma and its application to a large extraction area negative ion source. Wada, Motoi; Takeshima, Shigeki; Tsuda, Hiroshi; Sasao, Mamiko // Review of Scientific Instruments;Jan1990, Vol. 61 Issue 1, p430 

    A sheet plasma with a thickness as thin as several millimeters was produced by the combination of a pair of dipole magnetic fields and a mirror magnetic field. The negative hydrogen ion produced in the peripheral region of the sheet plasma was measured with a movable Faraday cup. The maximum...

  • High-intensity plasma-sputter heavy negative-ion source (invited). Alton, G. D.; Mori, Y.; Takagi, A.; Ueno, A.; Fukumoto, S. // Review of Scientific Instruments;Jan1990, Vol. 61 Issue 1, p372 

    A multicusp magnetic field plasma-surface ion source, normally used for H[sup -] ion-beam formation, has been modified for the generation of high-intensity, pulsed, heavy-negative-ion beams suitable for a variety of uses. A brief description of the source and basic pulsed-mode operational data...

  • Subcutoff microwave driven plasma ion sources for multielemental focused ion beam systems. Mathew, Jose V.; Chowdhury, Abhishek; Bhattacharjee, Sudeep // Review of Scientific Instruments;Jun2008, Vol. 79 Issue 6, p063504 

    A compact microwave driven plasma ion source for focused ion beam applications has been developed. Several gas species have been experimented including argon, krypton, and hydrogen. The plasma, confined by a minimum B multicusp magnetic field, has good radial and axial uniformity. The octupole...

  • Study of Multi-cusp Magnetic Field in Cylindrical Geometry for H- Ion Source. Kumar, Ajeet; Senecha, V. K.; Vadjikar, R. M. // AIP Conference Proceedings;3/12/2009, Vol. 1097 Issue 1, p137 

    The computation of magnetic field generated by the permanent magnets (PM) in the multipole configuration in a cylindrical geometry has been carried out analytically and compared with the experimental measurements. It has been shown that the magnetic field intensity variation inside the...

  • A slab-shaped electron cyclotron resonance ion beam source for in-line running target treatments. Roy, V.; Wartski, L.; Boukari, F.; Momy, A.; Schwebel, C.; Coste, Ph.; Aubert, J. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1000 

    Presents results of investigations of an immersed electron cyclotron resonance slab-shaped ion source. Features of the ion source; Design of the elementary module; Optimization of the magnetic field intensity; Level of ion density in an argon plasma at different points.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics