ABSTRACT
The present study is intended to investigate and compare the hemodynamics in two different sizes of hemodialysis arteriovenous grafts for upper arm hemodialysis vascular access: 8-mm tapered to 6-mm at the arterial side and straight 6 mm. A computational simulation approach is presented for this study, which is validated against the available experimental and numerical pressure measurements in the literature. The imposed boundary conditions at the arterial inlet and venous outlet boundaries of the models are physiological velocity and pressure waveforms, respectively. Blood flow fields and distribution patterns of the hemodynamic indices including wall shear stress (WSS) as one of the major hemodynamic parameters of the cardiovascular system and spatial wall shear stress gradient (SWSSG) as an indicator of disturbed flow patterns and hence susceptible sites of lesion developments are analyzed and compared between the two grafts. The tapered 6- to 8-mm graft seemingly is associated with less disturbed flow patterns within the venous anastomosis (VA) and the vein downstream while benefiting from higher blood flow rates within. Also, it shows a definitive advantage in terms of WSS and SWSSG distribution patterns around the VA and throughout the vein downstream with significantly lower values, which reduce the risk of thrombosis formation and stenotic lesion developments. The only disadvantage encountered in using 6- to 8-mm tapered graft is higher values of hemodynamic parameters at the arterial junction attributable to its significantly higher mean blood flow rate within. The results clearly indicate that the tapered 6- to 8-mm graft entirely outperforms straight 6-mm graft hemodynamically as an upper arm hemodialysis vascular access graft and confirms clinical data in the literature, which suggests advantageous use of tapered 6- to 8-mm grafts in the creation of upper arm brachioaxillary hemodialysis vascular access grafts in selected groups of patients with expectably higher patency rates and lower complications.
ACCESSION #
97503432

 

Related Articles

  • Forensic issues in cases of fatal hemorrhage from arteriovenous dialysis access sites. Ross James // Forensic Science, Medicine & Pathology;Jun2007, Vol. 3 Issue 2, p128 

    Abstract  Angioaccess sites to enable repetitive vascular punctures for hemodialysis include temporary or permanent indwelling catheters, port access devices, autogenous vessels in native arteriovenous fistulas, or non-autogenous material in prosthetic arteriovenous grafts. While...

  • Placing a primary arteriovenous fistula that works—more or less known aspects, new ideas. Konner, Klaus; Lomonte, Carlo; Basile, Carlo // Nephrology Dialysis Transplantation;Apr2013, Vol. 28 Issue 4, p781 

    Despite the pre-operative availability of well-defined criteria to create a primary arteriovenous fistula (AVF) a high early failure/missing maturation is complained worldwide. Based on new results from basic research using numerical techniques, the authors try to guide attention to a widely...

  • Impact of Cuffed, Expanded Polytetrafluoroethylene Dialysis Grafts on Graft Outlet Stenosis. Liu, Yun-Hen; Hung, Yen-Ni; Hsieh, Hung-Chang; Ko, Po-Jen // World Journal of Surgery;Dec2006, Vol. 30 Issue 12, p2290 

    The objective of this study was to determine prospectively the difference between the graft outlet strictures of a polytetrafluoroethylene (ePTFE) graft with a cuff at the graft-vein anastomosis (Venaflo; Bard industries, Tempe, Ariz.) and that of the regular ePTFE graft (Stretch Gore-Tex; Gore,...

  • Proactive monitoring of pediatric hemodialysis vascular access: effects of ultrasound dilution on thrombosis rates. Goldstein, Stuart L.; Allsteadt, Amelia; Smith, Carolyn M.; Currier, Helen // Kidney International;Jul2002, Vol. 62 Issue 1, p272 

    Background: Hemodialysis vascular access thrombosis (VAT) is a significant cause of morbidity for hemodialysis patients and results, in part, from decreased access flow potentially caused by venous outflow stenosis. We have previously shown ultrasound dilution (UD) to be a practical...

  • Is Surgical Thrombectomy to Salvage Failed Autogenous Arteriovenous Fistulae Worthwhile? Palmer, Robert M.; Cull, David L.; Kalbaugh, Corey; Carsten, Christopher G.; Taylor, Spence M.; Snyder, Bruce A.; York, John W.; Langan, Eugene M.; Blackhurst, Dawn // American Surgeon;Dec2006, Vol. 72 Issue 12, p1231 

    The Dialysis Outcomes Quality Initiatives guidelines emphasize placement of autogenous arteriovenous (AV) fistulae for patients on hemodialysis. This recommendation is based on studies that demonstrate enhanced patency for AV fistulae compared with grafts. However, closer review of the data...

  • Cellular phenotypes in human stenotic lesions from haemodialysis vascular access. Roy-Chaudhury, Prabir; Yang Wang; Krishnamoorthy, Mahesh; Jianhua Zhang; Banerjee, Rupak; Munda, Rino; Heffelfinger, Sue; Arend, Lois // Nephrology Dialysis Transplantation;Sep2009, Vol. 24 Issue 9, p2786 

    Background. Haemodialysis vascular access dysfunction (due to venous stenosis and thrombosis) is a leading cause of hospitalization and morbidity. The aim of the current study was to identify the specific cell types present within stenotic tissue samples from patients with AV fistula and graft...

  • Computational and experimental simulations of the haemodynamics at cuffed arterial bypass graft anastomoses. Cole, J S; Wijesinghe, L D; Watterson, J K; Scott, D J A // Proceedings of the Institution of Mechanical Engineers -- Part H;Mar2002, Vol. 216 Issue 2, p135 

    The development of intimal hyperplasia at arterial bypass graft anastomoses is a major factor responsible for graft failure. A revised surgical technique, involving the incorporation of a small section of vein (vein cuff) into the distal anastomosis of polytetrafluoroethylene (PTFE) grafts,...

  • Anaphylaxis from the product(s) of ethylene oxide gas. Poothullil, J.; Shimzu, A.; Day, R.P.; Dolovich, J.; Shimizu, A // Annals of Internal Medicine;Jan75, Vol. 82 Issue 1, p58 

    Describes a patient who experienced typical systematic allergic reactions associated with hemodialysis and the use of a plastic and rubber connecting tube in an arteriovenous shunt. Overview of allergic reactions to low molecular weight substances; Signs and symptoms presented by the patient;...

  • Warfarin for Prevention of Vascular Access Thrombosis in Hemodialysis Patients. Pai, Amy Barton // Kidney;Sep/Oct2003, Vol. 12 Issue 5, p201 

    Focuses on the use of warfarin for the prevention of vascular access thrombosis in hemodialysis patients. Annual hospital admissions which result from vascular access related complications in hemodialysis patients; Pathogenesis of vascular access thrombosis; Clinical trials of warfarin for...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics