ABSTRACT
We demonstrated that the shot-to-shot timing jitter of an x-ray streak camera was reduced to close to 50 fs when it was triggered by a standard kilohertz laser with 1.2% rms pulse energy fluctuation. This was achieved by improving the response time of deflection plates and the rise time of the ramp pulse generated by a photoconductive switch, and by operating the photoconductive switch at optimum conditions. Furthermore, after reducing the angular distribution of electron bunch, the temporal resolution of the x-ray streak camera operating in accumulation mode was measured to be better than 600 fs.
ACCESSION #
9741812

 

Related Articles

  • Very high long-term stability synchroscan streak camera. Uhring, Wilfried; Zint, Chantal Virginie; Summ, Patrick; Cunin, Bernard // Review of Scientific Instruments;May2003, Vol. 74 Issue 5, p2646 

    In this article, we present the drifts phenomena that affect the temporal resolution of a standard synchroscan streak camera and some techniques to correct them in order to enhance the long-term resolution of these cameras. First, we give a comprehensive list of the components of the synchroscan...

  • Resolution characteristics of Lawrence Livermore National Laboratory soft x-ray streak cameras. Glendinning, S. G.; Medecki, H. // Review of Scientific Instruments;Aug1986, Vol. 57 Issue 8, p2184 

    Eight Lawrence Livermore National Laboratory (LLNL) x-ray streak cameras have been characterized for spatial resolution and for the line spread function contribution to the temporal resolution. The contrast transfer function of a gold resolution grid of varying spatial frequency was measured for...

  • Jitter-free subpicosecond streak cameras (invited). Belzile, C.; Kieffer, J. C.; Cote, C. Y.; Oksenhendler, T.; Kaplan, D. // Review of Scientific Instruments;Mar2002, Vol. 73 Issue 3, p1617 

    We review here our recent work on a high dynamic range, subpicosecond x-ray streak camera. Our subpicosecond streak camera (PX1) has been coupled to a 10 Hz Ti: sapphire laser system and tested with 500 fs UV light pulses (266 nm) in jitter-free accumulation mode. A novel design for the...

  • Streak Camera Characterization Using a Femtosecond Ti:Sapphire Laser. Ferianis, Mario; Danailov, Miltcho // AIP Conference Proceedings;2002, Vol. 648 Issue 1, p203 

    At ELETTRA a Streak Camera system is in operation since 1999. Several measurements have been performed so far on the diagnostic bending magnet beam line of the Storage Ring. This instrument has been also widely used during the Storage Ring FEL commissioning to fully characterize both the...

  • Chromatic time lag in picosecond-streak-camera objectives. Ihlemann, J.; Helmbold, A.; Staerk, H. // Review of Scientific Instruments;Nov88, Vol. 59 Issue 11, p2502 

    Wavelength-dependent time lags due to group velocity dispersion (GVD)—much larger than estimated and documented thus far—have been determined experimentally for some widely used streak camera objectives. Correction procedures for signals delayed and broadened by group dispersion in...

  • Multislit streak photography for plasma dynamics studies. Tou, T. Y.; Lee, S. // Review of Scientific Instruments;Nov88, Vol. 59 Issue 11, p2370 

    A microscope slide with several transparent slits installed in a streak camera is used to record time-resolved two-dimensional information when a curved luminous plasma sheath traverses these slits. Applying this method to the plasma focus experiment, the axial run-down trajectory and the shapes...

  • In situ calibration of a streak camera in nanosecond region with a sequenced multispark switch. Tou, T. Y. // Review of Scientific Instruments;Jan1993, Vol. 64 Issue 1, p125 

    This article presents an in situ calibration of a streak camera from 500 ps/mm to 20 ns/mm of streak speeds with an adjustable time-sequenced multispark switch. This switch is comprised of a trigatron which drives two other secondary sparks separated in time from several nanoseconds to almost 1...

  • Neutron streak tube. Wang, C. L.; Lerche, R. A.; Medecki, H.; Phillips, G. E.; Singh, M. S. // Review of Scientific Instruments;Aug1986, Vol. 57 Issue 8, p1749 

    We present the design and construction of a simple neutron streak tube. The cathode is a 10-µmthick U[sup 238] strip, 25 mm wide and 1.5 mm high, vacuum deposited on a stainless-steel substrate which replaces the cathode of a Lawrence Livermore National Laboratory (LLNL) model 3 xray streak...

  • Electron trapping materials for use in picosecond infrared streak camera. Wenhui Fan; Xun Hou // Review of Scientific Instruments;Dec1999, Vol. 70 Issue 12, p4482 

    Describes the employment of an infrared upconversion screen made of electron trapping material in combination with the high sensitivity of the S-20 photocathode responsive to visible radiation to produce a streak camera arrangement capable of viewing and recording infrared incident pulses. Peak...

Share