TITLE

Turbulent Flow Characteristics in Internally Grooved Pipe

AUTHOR(S)
Sunu, Putu Wijaya; Wardana, I. N. G.; Sonief, A. A; Hamidi, Nurkholis
PUB. DATE
June 2014
SOURCE
Australian Journal of Basic & Applied Sciences;Jun2014, Vol. 8 Issue 9, p187
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Turbulent flow characteristics in internally grooved pipe have been investigated experimentally. The observation has been done at number of groove of 24, 32 and smooth pipe used as comparison. The results indicate that in the 24 groove, vortices of lesser size than the groove width thereby causing the flow to rotate, increasing both radial velocity and pressure drop. Whereas, in the 32-groove, the vortices diameter is larger than the groove width so that the fluid did not rotate which reduced radial velocity and pressure drop. In this study, the critical conditions were estimated from the time the fluid rotation actually commenced in the smooth pipe (no grooves) which was then correlated to both the 24 groove and 32 groove pipes. Critical conditions occurred when pressure drop reached 240 Pa and the skewness factor of pressure drop changed from negative to positive or vice versa. When critical conditions were correlated to pipe with 24 groove and 32 grooves, it was found that groove arrangement determine the strengthening or weakening of the turbulent flow characteristics.
ACCESSION #
97368415

 

Related Articles

  • TURBULENCE AND PRESSURE DROP BEHAVIORS AROUND SEMICIRCULAR RIBS IN A RECTANGULAR CHANNEL. NINE, Md. Julker; LEE, Gyeong Hwan; HanShik CHUNG; JI, Myoungkuk; Hyomin JEONG // Thermal Science;2014, Vol. 18 Issue 2, p419 

    The article represents an experimental investigation on friction and turbulent flow characteristics of free airflow through a rectangular duct fitted with semicircular ribs of uniform height (e = 3.5 mm) on one principle wall. The aspect ratio of the rectangular duct was AR= 5 where the duct...

  • An experimental study on the pressure drop and heat transfer through straight and curved small diameter tubes. Kim, Sang; Ha, Man; Son, Changmin; Jeong, Ji // Journal of Mechanical Science & Technology;Feb2014, Vol. 28 Issue 2, p797 

    A tube type heat exchanger is often the only solution when minimum pressure loss is a requirement. In addition, small diameter tubes are preferable because of an increased heat transfer area within an acceptable pressure loss limit. The present work reports on both an analytic model and...

  • Heat transfer and pressure drop comparison between smooth and different sized rib-roughened rectangular divergent ducts. Sivakumar, K.; Kulasekharan, N.; Natarajan, E. // International Journal of Engineering & Technology (0975-4024);Feb/Mar2014, Vol. 6 Issue 1, p263 

    the work reported in this paper is a systematic experimental heat transfer and pressure drop comparison between smooth and three different sized square ribbed divergent rectangular ducts. The heights of the rib turbulators (e) were 3, 6 and 9 mm. This yields an rib height (e) to mean hydraulic...

  • Effect of divergence ratio on heat transfer and friction factor in the ribbed rectangular channel. Lee, Myung; Jeong, Seong; Ahn, Soo; Lee, Dae // Journal of Mechanical Science & Technology;Dec2013, Vol. 27 Issue 12, p3911 

    The local heat transfer and pressure drop of turbulent flows developed in stationary ribbed rectangular divergent channels are experimentally investigated. The rectangular divergent channels with a one sided ribbed surface only have inclination angles of 0.72° and 1.43°. The ribbed wall is...

  • Numerical investigation of turbulent flow heat transfer and pressure drop of AL2O3/water nanofluid in helically coiled tubes. Elsayed, Ahmed; Al-dadah, Raya K.; Mahmoud, Saad; Rezk, Ahmed // International Journal of Low Carbon Technologies;Sep2015, Vol. 10 Issue 3, p275 

    Passive convective heat transfer enhancement can be achieved by improving the thermo-physical properties of the working fluid, changing flow geometry or both. This work presents a numerical study to investigate the combined effect of using helical coils and nanofluids on the heat transfer...

  • AN ALGORITHM FOR OPTIMAL SELECTION OF HEAT TRANSFER AND FLUID FLOW CORRELATION FOR COMPACT HEAT TRANSFER SURFACES. DIACONU, BOGDAN; ANGHELESCU, LUCICA // Annals of 'Constantin Brancusi' University of Targu-Jiu. Enginee;2015, Issue 2, p118 

    Heat transfer and fluid flow correlation are generally derived from experimental data, which are affected by various kinds of errors. Transition from laminar to turbulent regime is a sensitive issue that depends on many factors. In complex geometry it is not possible to predict a transition...

  • Experimental Study of Heat Transfer Enhancement in a Heated Tube Caused by Wire-Coil and Rings. Vahidifar, S.; Kahrom, M. // Journal of Applied Fluid Mechanics;2015, Vol. 8 Issue 4, p885 

    This study investigates heat transfer characteristics and the pressure drop of a horizontal double pipe heat exchanger with wire coil inserts. The amplification of convection heat transfer coefficient in the heat exchanger reduces the weight, size and cost of heat exchanger. One way of...

  • A Numerical Approach for Estimating the Entropy Generation in Cylindrical Heat Pipes. Maheshkumar, P.; Muraleedharan, C. // International Journal of Applied Engineering Research;2010, Vol. 5 Issue 12, p2049 

    Heat Pipe is a thermodynamic device which transports heat from one location to another with a very small temperature drop. Entropy generation can be considered as a significant parameter on heat pipe performance. Major reasons for entropy generation in a heat pipe system are temperature...

  • Heat transfer enhancement and pressure drop analysis in a helically coiled tube using AlO / water nanofluid. Kumar, P.; Kumar, J.; Tamilarasan, R.; Sendhil Nathan, S.; Suresh, S. // Journal of Mechanical Science & Technology;May2014, Vol. 28 Issue 5, p1841 

    In this experimental investigation, the heat transfer and pressure drop analysis of a shell and helically coiled tube heat exchanger by using AlO / water nanofluids have been carried out under turbulent flow condition. The AlO/ water nanofluids of 0.1%, 0.4%, and 0.8% particle volume...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library