Caval collapse during cardiopulmonary bypass: a reproducible bench model

AUTHOR(S)
Li, Liang; Abdel-Sayed, Saad; Berdajs, Denis; Tozzi, Piergiorgio; von Segesser, Ludwig K.; Ferrari, Enrico
PUB. DATE
August 2014
SOURCE
European Journal of Cardio-Thoracic Surgery;Aug2014, Vol. 46 Issue 2, p306
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
OBJECTIVES During open heart surgery, so-called atrial chatter, a phenomenon due to right atria and/or caval collapse, is frequently observed. Collapse of the cava axis during cardiopulmonary bypass (CPB) limits venous drainage and may result downstream in reduced pump flow on (lack of volume) and upstream in increased after-load (stagnation), which in turn may both result in reduced or even inadequate end-organ perfusion. The goal of this study was to reproduce venous collapse in the flow bench. METHODS In accordance with literature for venous anatomy, a caval tree system is designed (polyethylene, thickness 0.061 mm), which receives venous inflow from nine afferent veins. With water as medium and a preload of 4.4 mmHg, the system has an outflow of 4500 ml/min (Scenario A). After the insertion of a percutaneous venous cannula (23-Fr), the venous model is continuously served by the afferent branches in a venous test bench and venous drainage is augmented with a centrifugal pump (Scenario B). RESULTS With gravity drainage (siphon: A), spontaneously reversible atrial chatter can be generated in reproducible fashion. Slight reduction in the outflow diameter allows for generation of continuous flow. With augmentation (B), irreversible collapse of the artificial vena cava occurs in reproducible fashion at a given pump speed of 2300 ± 50 RPM and a pump inlet pressure of −112 mmHg. Furthermore, bubbles form at the cannula tip despite the fact that the entire system is immersed in water and air from the environment cannot enter the system. This phenomenon is also known as cavitation and should be avoided because of local damage of both formed blood elements and endothelium, as well embolization. CONCLUSIONS This caval model provides a realistic picture for the limitations of flow due to spontaneously reversible atrial chatter vs irreversible venous collapse for a given negative pressure during CPB. Temporary interruption of negative pressure in the venous line can allow for recovery of venous drainage. This know-how can be used not only for testing different cannula designs, but also for further optimizing perfusion strategies.
ACCESSION #
97327803

 

Related Articles

  • Haemolysis during cardiopulmonary bypass: an in vivo comparison of standard roller pumps, nonocclusive roller pumps and centrifugal pumps. Hansbro, S.D.; Sharpe, D.A.C.; Catchpole, R.; Welsh, K.R.; Munsch, C.M.; McGoldrick, J.P.; Kay, P.H. // Perfusion;1999, Vol. 14 Issue 1, p3 

    Cardiopulmonary bypass (CPB) involves the use of either an occlusive roller pump or centrifugal pump. Damage to blood elements, including haemolysis, may arise from occlusion when using a roller pump; the appropriate degree of occlusion has not yet been determined scientifically. Centrifugal and...

  • Cardiopulmonary bypass in the immature fetus through novel use of a mini-centrifugal pump. Lombardi, John; Sedgwick, Joseph; Schenbeck, Jennifer; Lubbers, Walter; Ferguson, Robert E; Gardner, Aimee; McNamara, Jerri L; Eghtesady, Pirooz // Perfusion;May2006, Vol. 21 Issue 3, p185 

    The concept that the natural history of certain heart defects could be positively modified through in utero intervention has stimulated extensive research in fetal cardiac intervention and surgery since the early 1980s. Since the management of certain defects would require the use of...

  • Effects of centrifugal and roller pumps on survival of autologous red cells in cardiopulmonary bypass surgery. Valeri, C. R.; MacGregor, H.; Ragno, G.; Healey, N.; Fonger, J.; Khuri, S. F. // Perfusion;Sep2006, Vol. 21 Issue 5, p291 

    Background: Either a roller pump or a centrifugal pump can be used in the extracorporeal circuit during surgery with cardiopulmonary bypass. In this study, we assessed the effect of these two pumps on the 24-h post-transfusion survival values of autologous red blood cells (RBC). Study design and...

  • Extracorporeal membrane oxygenation, an anesthesiologist's perspective: Physiology and principles. Part 1. Chauhan, Sandeep; Subin, S. // Annals of Cardiac Anaesthesia;Sep2011, Vol. 14 Issue 3, p218 

    Extracorporeal membrane oxygenation (ECMO) is an adaptation of conventional cardiopulmonary bypass techniques to provide cardiopulmonary support. ECMO provides physiologic cardiopulmonary support to aid reversible aspects of the disease process and to allow recovery. ECMO does not provide...

  • A Minimally Invasive Technique for Occluding Large Muscular Ventricular Septal Defects in Infants. Gao, Zibo; Wu, Qin; Zhao, Tianli; Yin, Ni; Gao, Lei; Xu, Xinhua; Xie, Li; Yang, Yifeng; Yang, Jinfu // Cardiology;Feb2014, Vol. 127 Issue 3, p196 

    Objective: This study investigated the feasibility, timing and indications for closure of large muscular ventricular septal defects (VSDs) in infants without use of a cardiopulmonary bypass. Methods: A total of 9 infants with large muscular VSDs ranging in size from 7 to 15 mm were treated by...

  • Adjustment of sweep gas flow during cardiopulmonary bypass. Karabulut, Hasan; Toraman, Fevzi; Tarcan, Sümer; Demirhisar, Önder; Alhan, Cem // Perfusion;Sep2002, Vol. 17 Issue 5, p353 

    Cardiopulmonary bypass (CPB) is one of the major tools of cardiac surgery. However, no clear data are available for the ideal value of sweep gas flow to oxygenator during CPB. The aim of this study was to determine the best value for sweep gas flow during CPB. Thirty patients undergoing isolated...

  • Liver function tests and hyperbilirubinemia in adult patients undergoing open heart surgery. Yuksel, Ahmet; Tuydes, Oktay; Minbay, Hakan; Bicer, Murat; Saba, Davit // Journal of Turgut Ozal Medical Center;2016, Vol. 23 Issue 4, p357 

    Aim: The effects of cardiac surgery and cardiopulmonary bypass on postoperative liver function tests and hyperbilirubinemia in adult patients undergoing open heart surgery were studied, and related literature was reviewed and compared with our results. Materials and Methods: Between January 2013...

  • Erratum to: Cerebral Near-Infrared Spectroscopy Correlates to Vital Parameters During Cardiopulmonary Bypass Surgery in Children. Menke, Jan; Möller, Gerhard // Pediatric Cardiology;Aug2014, Vol. 35 Issue 6, p1082 

    A correction to the article "Cerebral Near-Infrared Spectroscopy Correlates to Vital Parameters During Cardiopulmonary Bypass Surgery in Children" that was published in the previous issue is presented.

  • Leukocyte filtration in cardiac surgery: a review. Matheis, G.; Scholz, M.; Simon, A.; Dzemali, O.; Moritz, A. // Perfusion;Sep2001, Vol. 16 Issue 5, p361 

    Leukocyte filtration has evolved as an important technique in cardiac surgery with cardiopulmonary bypass to prevent pathogenic effector functions mediated by activated leukocytes. The underlying mechanisms that result in an improvement of laboratory variables as well as clinical outcome are not...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics