TITLE

Active and reactive power flow regulation for a grid connected vsc based on fuzzy controllers

AUTHOR(S)
Aldana, Nelson Díaz; Trujillo, César Leonardo; Guarnizo, José Guillermo
PUB. DATE
March 2013
SOURCE
Revista Facultad de Ingenieria Universidad de Antioquia;mar2013, Issue 66, p118
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Voltage Source Converters (VSC) are one of the most used converters in distributed generation application and HVDC systems, since a VSC can operate either as inverter or rectifier. Furthermore, a VSC allows fast, accurate and independent active and reactive power flow control. However, a VSC is a double- input double-output non-linear control objet, therefore; nonlinear control strategies can be useful in order to obtain desired behaviors. In particular, knowledge based fuzzy controller does not require a mathematic model of the system it just relies on a qualitative knowledge about the behavior of the system. Moreover, the same fuzzy controller can be applied to any VSC with any power ratio. This paper presents the analysis, design and results obtained by using fuzzy controllers for regulating the active and reactive power flow in a Voltage Source Converter (VSC) connected to the utility grid. Additionally, it is shown that the transitory and stationary response of the VSC depends on the shape of membership functions at different power ratios. Digital simulation was performed in order to verify the behavior of the controller under different power levels. Finally, a VSC prototype with fuzzy controllers was tested experimentally.
ACCESSION #
97266155

 

Related Articles

  • AN ENHANCEMENT OF POWER QUALITY BY USING FUZZY LOGIC CONTROLLER FOR TYPICAL HOUSEHOLD APPLICATIONS. PURUSHOTHAM, A.; VARDHAN, M. VISHNU // I-Manager's Journal on Circuits & Systems;Sep-Nov2016, Vol. 4 Issue 4, p19 

    This paper proposes a transformerless hybrid series active filter which is connected to a single phase distribution feeder. This system uses a sliding mode controller and filtering techniques to reduce voltage and current harmonics for a typical nonlinear load (VSC). The reactive power...

  • ADVANCED CONTROL TECHNIQUES IN VARIABLE SPEED STAND ALONE WIND TURBINE SYSTEM. Deve, V. Sharmila; Karthiga, S. // International Journal of Advances in Engineering & Technology;Mar2012, Vol. 3 Issue 1, p549 

    This project presents an advanced control strategy for the operation of a direct-drive synchronous generator-based stand-alone variable-speed wind turbine. The control strategy for the generator-side converter with maximum power extraction is presented. The stand-alone control featured is...

  • Control of CSR PWM outer current loop based on fuzzy algorithm. Zhuo Wang; Zhang Qing // Applied Mechanics & Materials;2014, Issue 667-679, p972 

    This paper expounds the double closed-loop control configuration which is composed by the AC inner current control loop and the DC outer current loop of the CSR PWM rectifier ,and the functions of the inner current loop and the outer current control loop are pointed out. To improve the control...

  • Optimal switching sequence model predictive control for three-phase Vienna rectifiers. Shiming Xie; Yao Sun; Mei Su; Jianheng Lin; Qiming Guang // IET Electric Power Applications;2018, Vol. 12 Issue 7, p1006 

    Vienna rectifier is a typical three-level rectifier with complicated operating constraints. Also, the constraints pose a challenge for designing controllers with good dynamic performance. As predictive control is good at dealing with constraints, an optimal switching sequence model predictive...

  • Design and implementation of perturbation observer-based robust passivity-based control for VSC-MTDC systems considering offshore wind power integration. Yiyan Sang; Bo Yang; Wei Yao; Lin Jiang // IET Generation, Transmission & Distribution;2018, Vol. 12 Issue 10, p2415 

    Voltage source converter-based multi-terminal high-voltage direct current (VSC-MTDC) systems are starting to be commissioned. However, concentrated integration of large-scale wind power demands stronger robustness against power fluctuation and system disturbances to increase the reliability of...

  • Time-reversal duality of high-efficiency RF power amplifiers. Reveyrand, T.; Ramos, I.; Popović, Z. // Electronics Letters;12/6/2012, Vol. 48 Issue 25, p29 

    The similarity between RF power amplifiers and rectifiers is discussed. It is shown that the same high-efficiency harmonically-terminated power amplifier can be operated in a dual rectifier mode. Nonlinear simulations with a GaN HEMT transistor model show the time-reversal intrinsic voltage and...

  • Pulse Width Modulated Thyristor CSI for Grid Connected Photovoltaic Applications. Kulkarni, G. R.; Kalani, Nilesh B. // Journal of Active & Passive Electronic Devices;2013, Vol. 8 Issue 1, p47 

    A new three phase active commutated thyristor current source inverter (CSI) topology is proposed for grid connected photovoltaic systems. Space vector PWM with a special switching sequence, which ensures proper commutation of thyristors, is implemented. In order to suppress the natural frequency...

  • Power Factor Correction Rectifier with a Variable Frequency Voltage Source in Vehicular Application. Toumi, Amine; Mohamed Radhouan Hachicha; Ghariani, Moez; Neji, Rafik // Intelligent Control & Automation (2153-0653);Feb2014, Vol. 5 Issue 1, p1 

    This paper presents a PFCVF (Power Factor Correction) rectifier that uses a variable frequency source for alternators for electric and hybrid vehicles application. In such application, the frequency of the signal in the alternator changes according to the vehicle speed, more over the loading...

  • Study of New Three- phase Voltage Source PWM Rectifier. Zeng zhihui; Zhang yiming; Yu Fei; Feng jinlan // International Journal of Digital Content Technology & its Applic;Mar2013, Vol. 7 Issue 6, p1088 

    It has been established that a mathematical model for the three-phase voltage source PWM rectifier based on the three-phase stationary symmetric coordinate system (a, b, c) and two-phase synchronous rotating coordinate system (d, q); adopted the power feedforward decouping control strategy, a...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?