TITLE

Reproducibility of In-Vivo OCT Measured Three-Dimensional Human Lamina Cribrosa Microarchitecture

AUTHOR(S)
Wang, Bo; Nevins, Jessica E.; Nadler, Zach; Wollstein, Gadi; Ishikawa, Hiroshi; Bilonick, Richard A.; Kagemann, Larry; Sigal, Ian A.; Grulkowski, Ireneusz; Liu, Jonathan J.; Kraus, Martin; Lu, Chen D.; Hornegger, Joachim; Fujimoto, James G.; Schuman, Joel S.
PUB. DATE
April 2014
SOURCE
PLoS ONE;Apr2014, Vol. 9 Issue 4, p1
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Purpose: To determine the reproducibility of automated segmentation of the three-dimensional (3D) lamina cribrosa (LC) microarchitecture scanned in-vivo using optical coherence tomography (OCT). Methods: Thirty-nine eyes (8 healthy, 19 glaucoma suspects and 12 glaucoma) from 49 subjects were scanned twice using swept-source (SS−) OCT in a 3.5×3.5×3.64 mm (400×400×896 pixels) volume centered on the optic nerve head, with the focus readjusted after each scan. The LC was automatically segmented and analyzed for microarchitectural parameters, including pore diameter, pore diameter standard deviation (SD), pore aspect ratio, pore area, beam thickness, beam thickness SD, and beam thickness to pore diameter ratio. Reproducibility of the parameters was assessed by computing the imprecision of the parameters between the scans. Results: The automated segmentation demonstrated excellent reproducibility. All LC microarchitecture parameters had an imprecision of less or equal to 4.2%. There was little variability in imprecision with respect to diagnostic category, although the method tends to show higher imprecision amongst healthy subjects. Conclusion: The proposed automated segmentation of the LC demonstrated high reproducibility for 3D LC parameters. This segmentation analysis tool will be useful for in-vivo studies of the LC.
ACCESSION #
95819953

 

Related Articles

  • Multivariable Logistic Regression Model: A Novel Mathematical Model that Predicts Visual Field Sensitivity from Macular Ganglion Cell Complex Thickness in Glaucoma. Shiba, Daisuke; Hatou, Shin; Ono, Takeshi; Hosoda, Shingo; Tanabe, Sachiko; Ozeki, Naoki; Yuki, Kenya; Shimoyama, Masaru; Fukagawa, Kazumi; Shimmura, Shigeto; Tsubota, Kazuo // PLoS ONE;Aug2014, Vol. 9 Issue 8, p1 

    Purpose: To design a mathematical model that can predict the relationship between the ganglion cell complex (GCC) thickness and visual field sensitivity (VFS) in glaucoma patients. Design: Retrospective cross-sectional case series. Method: Within 3 months from VFS measurements by the Humphrey...

  • Imaging the Invisible: Retinal Cells In Vivo. Kent, Christopher // Review of Ophthalmology;May2009, Vol. 16 Issue 5, p21 

    The article reports on the development of a new technology that improve the ability to see individual cells in the retina in 3-D in vivo in the U.S. John S. Werner is the head investigator for the Bioengineering Research Partnership where the group's work has been deemed, the Hubble telescope of...

  • Visualizing the hill of vision in 3D using the free programming language 'R'. Asaoka, Ryo; Russell, Richard; Crabb, David; Garway-Heath, David // Graefe's Archive of Clinical & Experimental Ophthalmology;Jan2013, Vol. 251 Issue 1, p391 

    No abstract available.

  • UBM, AS-OCT useful adjuncts. Radhakrishnan, Sunita; Krader, Cheryl Guttman // Ophthalmology Times;7/1/2012, Vol. 37 Issue 13, p23 

    The article discusses a study that investigates the performance of ultrasound biomicroscopy (UBM) and anterior segment optical coherence tomography (AS-OCT) in treating glaucoma patients, presented at Glaucoma Symposium 2012. It is given that AS-OCT and UBM provided quantitative analysis and...

  • Retinal nerve fibre layer evaluation in ocular hypertensive eyes using optical coherence tomography and scanning laser polarimetry in the diagnosis of early glaucomatous defects. Pablo, Luis E.; Ferreras, Antonio; Schlottmann, Patricio G. // British Journal of Ophthalmology;Jan2011, Vol. 95 Issue 1, p51 

    Aims To evaluate and compare the accuracy of scanning laser polarimetry with variable corneal compensation (GDx-VCC) and optical coherence tomography (OCT) for detecting glaucomatous damage observed in retinal nerve fibre layer (RNFL) monochromatic photographs from ocular hypertensive (OHT)...

  • SD-OCT produces better results of RNFL thickness imaging than SLR study shows. Petrou, Ilya; Mardin, Christian Y. // Ophthalmology Times;8/15/2008, Vol. 33 Issue 16, p40 

    The article presents information on a study conducted at the Department of Ophthalmology at the University of Erlangen, Erlangen, Germany, according to which spectral-domain optical coherence tomography (SD-OCT) can provide better results in the imaging of retinal nerve fiber (RNF) loss in...

  • Is the ISNT rule helpful? Casella, Benjamin P. // Optometry Times;Jul2014, Vol. 6 Issue 7, p12 

    The article reports on the utility of the ISNT rule in the glaucoma eye condition as of July 2014. It references the article by JE Morgan et al in the April 2012 issue of "Ophthalmology." Topics discussed include the substance of the mnemonic ISNT rule, its limited clinical value, and the...

  • Anterior Segment Optical Coherence Tomography Imaging of Haab Striae. Spierer, Oriel; Cavuoto, Kara M.; Suwannaraj, Sirinya; Chang, Ta C. // Journal of Pediatric Ophthalmology & Strabismus;10/15/2015, Vol. 52, Following pe55 

    The authors present a case series demonstrating the anterior segment optical coherence tomography (AS-OCT) findings of Haab striae in three patients with congenital glaucoma. The use of AS-OCT in the assessment of Haab striae in pediatric glaucoma is novel, previously undescribed, and possibly...

  • Clinical utility of anterior segment swept-source optical coherence tomography in glaucoma. Dewang Angmo; Nongpiur, Monisha E.; Sharma, Reetika; Sidhu, Talvir; Sihota, Ramanjit; Dada, Tanuj // Oman Journal of Ophthalmology;Feb2016, Vol. 9 Issue 1, p3 

    Optical coherence tomography (OCT), a noninvasive imaging modality that uses low-coherence light to obtain a high-resolution cross-section of biological structures, has evolved dramatically over the years. The Swept-source OCT (SS-OCT) makes use of a single detector with a rapidly tunable laser...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics