TITLE

Determination of Ibuprofen in Human Plasma and Urine by Gas Chromatography/Mass Spectrometry

AUTHOR(S)
YILMAZ, BILAL; ERDEM, ALI FUAT
PUB. DATE
March 2014
SOURCE
Journal of AOAC International;Mar/Apr2014, Vol. 97 Issue 2, p415
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
This paper describes a GC/MS method for the determination of ibuprofen in human plasma and urine. Ibuprofen and internal standard naproxen were extracted from plasma and urine by using a liquid-liquid extraction method. Derivatization was carried out using N-methyl-N-(trimethylsilyl) trifluoroacetamide. Calibration curves were linear over the concentration range of 0.05-5.0 and 0.1-10.0 µg/mL for plasma and urine, respectively. Intraday and interday precision (RSD) values for ibuprofen in plasma and urine were less than 6.31%, and accuracy (relative error) was better than 12.00%. The mean recovery of ibuprofen was 89.53% for plasma and 93.73% for urine. The LOD was 0.015 and 0.03 µg/mL and the LOQ was 0.05 and 0.1 µg/mL for plasma and urine, respectively. The method was successfully applied to blood samples from three healthy male volunteers who had been given an oral tablet of 600 mg ibuprofen.
ACCESSION #
95633969

 

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library