TITLE

Alpha and recoil track detection in poly(methyl methacrylate) (PMMA)--Towards a method for in vitro assessment of radiopharmaceuticals internalized in cancer cells

AUTHOR(S)
Myhra, S.; Falzone, N.; Chakalova, R.
PUB. DATE
March 2014
SOURCE
Review of Scientific Instruments;2014, Vol. 85 Issue 3, p1
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A method for detection and characterization of single MeV α-particle and recoil tracks in PMMA photoresist by atomic force microscopy (AFM) analysis has been demonstrated. The energy deposition along the track is shown to lead to a latent pattern in the resist due to contrast reversal. It has been shown that the pattern, consisting of conical spikes, can be developed by conventional processing as a result of the dissolution rate of poly(methyl methacrylate) (PMMA) being greater than that for the modified material in the cylindrical volume of the track core. The spikes can be imaged and counted by routine AFM analysis. Investigations by angular-resolved near-grazing incidence reveal additional tracks that correspond to recoil tracks. The observations have been correlated with modelling, and shown to be in qualitative agreement with prevailing descriptions of collision cascades. The results may be relevant to technologies that are based on detection and characterization of single energetic ions. In particular, the direct visualization of the collision cascade may allow more accurate estimates of the actual interaction volume, which in turn will permit more precise assessment of dose distribution of α-emitting radionuclides used for targeted radiotherapy. The results could also be relevant to other diagnostic or process technologies based on interaction of energetic ions with matter.
ACCESSION #
95315195

 

Related Articles

  • Three-dimensional beam tracking for optical lever detection in atomic force microscopy. Nakano, Katsushi; Yakimov, V.; Erlandsson, R. // Review of Scientific Instruments;Jan2000, Vol. 71 Issue 1 

    For the requirement to move a probe with respect to a large specimen like a silicon wafer, a three-dimensional beam tracking for optical lever force detection in atomic force microscopy has been developed. This beam tracking is not an approximate solution but an ideal solution in...

  • High Volume Single Molecule Force Spectroscopy Results.  // Labmate UK & Ireland;2011, Vol. 36 Issue 6, p15 

    The article reports on the results of the work from the Pharmaceutical Sciences Department of the Medical School at the University of Nebraska which used the JPK ForceRobot 300 system to extend studies applying the atomic force microscopy in the measurement of single molecule force spectroscopy.

  • Towards atomic force microscopy up to 100 MHz. Kawakatsu, H.; Kawai, S.; Saya, D.; Nagashio, M.; Kobayashi, D.; Toshiyoshi, H.; Fujita, H. // Review of Scientific Instruments;Jun2002, Vol. 73 Issue 6, p2317 

    An atomic force microscope for nanocantilevers measuring from a few 100 nm to a few µm in length was implemented. The natural frequencies of the nanocantilevers lie in the range of 1 MHz to 1 GHz, and optical detection schemes adapted to their size and frequency range was selected. A helium...

  • Calibration of the torsional spring constant and the lateral photodiode response of frictional force microscopes. Feiler, Adam; Attard, Phil; Larson, Ian // Review of Scientific Instruments;Jul2000, Vol. 71 Issue 7 

    We present a direct one-step technique to measure the torsional spring constant of cantilevers used for lateral or friction measurements with the atomic force microscope. The method simultaneously calibrates the photodiode response to the angular deflection of the cantilever. It does not rely...

  • Characterization and optimization of scan speed for tapping-mode atomic force microscopy. Sulchek, T.; Yaralioglu, G. G.; Quate, C. F.; Minne, S. C. // Review of Scientific Instruments;Aug2002, Vol. 73 Issue 8, p2928 

    Increasing the imaging speed of tapping mode atomic force microscopy (AFM) has important practical and scientific applications. The scan speed of tapping-mode AFMs is limited by the speed of the feedback loop that maintains a constant tapping amplitude. This article seeks to illuminate these...

  • A piezotube scanner for atomic force microscopy in solution. Jianxun Mou; Gang Huang; Zhifeng Shao // Review of Scientific Instruments;Jul96, Vol. 67 Issue 7, p2654 

    Describes a piezotube scanner used in the atomic force microscope (AFM). Advantages of the design; Significance of the design for biological AFM.

  • Device for the determination of spring constants of atomic force microscope cantilevers and micromachined springs. Jericho, S. K.; Jericho, M. H. // Review of Scientific Instruments;Jun2002, Vol. 73 Issue 6, p2483 

    We describe a simple device for the calibration of atomic force microscope cantilevers and micromachined springs. The device measures the deflection of the cantilevers in response to known forces that are derived from calibrated macroscopic cantilever springs. We have used the device to...

  • Atomic force microscope detector drift compensation by correlation of similar traces acquired at different setpoints. Kindt, Johannes H.; Thompson, James B.; Viani, Mario B.; Hansma, Paul K. // Review of Scientific Instruments;Jun2002, Vol. 73 Issue 6, p2305 

    The atomic force microscope measures surface topography by maintaining a certain cantilever deflection or vibration amplitude as the cantilever is scanned over a sample surface. The desired cantilever deflection or amplitude is referred to as the setpoint, and is maintained by moving the sample...

  • Nanoscale elasticity measurement with in situ tip shape estimation in atomic force microscopy. Yamanaka, Kazushi; Tsuji, Toshihiro; Noguchi, Atsushi; Koike, Takayuki; Mihara, Tsuyoshi // Review of Scientific Instruments;Jun2000, Vol. 71 Issue 6 

    For a quantitative evaluation of nanoscale elasticity, atomic force microscopy, and related methods measure the contact stiffness (or force gradient) between the tip and sample surface. In these methods the key parameter is the contact radius, since the contact stiffness is changed not only by...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics