TITLE

Design innovations provide for voltage-tunable, state-variable active filters for megahertz ranges

AUTHOR(S)
Siu, Chris
PUB. DATE
September 1995
SOURCE
EDN;9/28/95, Vol. 40 Issue 20, p117
SOURCE TYPE
Trade Publication
DOC. TYPE
Article
ABSTRACT
Features a new generation of wideband amplifiers and multipliers which allow the building of state-variable active filters that operate beyond the kilohertz region into the megahertz region. Provision of a very linear tuning characteristic; Problems at higher frequencies. INSET: Op-amp limitations play a role..
ACCESSION #
9512012340

 

Related Articles

  • Tunability of erbium-doped fibre ring laser based on bending loss of active fibre. Foroni, M.; Poli, F.; Cucinotta, A.; Selleri, S. // Electronics Letters;4/26/2007, Vol. 43 Issue 9, p500 

    A single frequency depressed-cladding erbium-doped fibre ring laser which can be tuned by exploiting the fibre bending losses has been proposed and experimentally demonstrated. A tunability range of about 44 nm, between 1491 and 1535 nm, has been measured. A saturable absorber formed by an...

  • Series Active Power Filter Using Generalised Instantaneous Power Theory. Mulla, M. A.; Chudamani, R.; Chowdhury, A. // Proceedings of the World Congress on Engineering 2012 Volume II;2012, p1 

    In the area of active power filtering, with an objective to reduce inverter capacity, the Series Hybrid Active Power Filter (SHAPF) has been taken into account increasingly. Existing method used for controlling SHAPF is either based on detecting source current harmonic or load voltage harmonics....

  • Study on Optimal Location of Multiple-Type Power Quality Improving Devices. Tiantian Sun; Wenzhong Ma; Xingtian Feng // Applied Mechanics & Materials;2014, Issue 667-679, p720 

    This paper presents a novel method for optimal location of multiple-type power quality improving devices in distribution network through lots of simulations in IEEE 30 bus system. Three type devices have been considered, active power filter (APF), dynamic voltage restorer (DVR) and static...

  • The DC-side active filter with dual-buck full-bridge inverter for wind generators. XIAO-QIANG CHEN; SHOU-WANG ZHAO; YING WANG // Archives of Electrical Engineering;2018, Vol. 67 Issue 2, p263 

    This paper proposes a new dc-side active filter for wind generators that combines 12-pulse polygon auto-transformer rectifier with dc-side current injection method and dual-buck full-bridge inverter having not the "shoot-through" problem in conventional bridge-type inverters, and therefore this...

  • Using the real-time simulator for prototyping power electronics inverter. BASZYNSKI, MARCIN; SZLOSEK, MARCIN // Archives of Electrical Engineering;2018, Vol. 67 Issue 2, p447 

    This paper deals with real-time (RT) simulators applied in power electronic applications and implemented in a real inverter. The process of preparing and starting up an active rectifier prototype (with an active filter function), using the real-time OPAL RT simulator is given. The control system...

  • Performance and Efficiency Study of Four-Wire Shunt Active Power Filters. Pettersson, S.; Salo, M.; Tuusa, H. // International Review of Electrical Engineering;May/Jun2008, Vol. 3 Issue 3, p444 

    Four-wire shunt active power filters have been intensively studied since the early 90's. Even though four-wire active power filter topologies are typically based on voltage source technology, some attention has also been paid to current source topologies. This paper presents a filtering...

  • Design Aspects of the Series Active Power Filter. Turunen, J.; Tuusa, H. // International Review of Electrical Engineering;Jan/Feb 2008, Vol. 3 Issue 1, p72 

    Active power filters have been developed to solve the growing harmonic problem occurring in the power network. Two main topologies of active power filters exist: the parallel active power filter and the series active power filter. In addition, there are also combinations of the active power...

  • A Novel Reference Current Estimation Schema for Active Power Filters without Synchronization Signal. Cakir, M. // International Review of Electrical Engineering;Jul/Aug2012, Vol. 7 Issue 4, p4684 

    In this paper a novel synchronization method is proposed to obtain a reference signal for active power filters (APF), which is used to determine the fundamental component of the load current in-phase with the mains voltage, without any signal measurement for synchronization. The principle idea...

  • Shunt Active Power Filters and PWM Rectifiers in Three-Phase Three Wire Systems: a Survey. B├írcenas, E.; C┬┤rdenas, V.; Arau, J. // International Review of Electrical Engineering;May/Jun2007, Vol. 2 Issue 3, p337 

    This paper presents a survey of recent approaches which addresses solutions for current harmonic reduction in three phase three wire systems. The analyzed works are the most representative solutions to obtain unity power factor in the mains and to fulfill the corresponding regulations; the...

  • Voltage-Source Active Power Filter with a Current Sensorless Control. Routimo, M.; Salo, M.; Tuusa, H. // International Review of Electrical Engineering;May/Jun2007, Vol. 2 Issue 3, p346 

    The harmonic filtering characteristic of a conventional shunt active filter is heavily dependent on the accuracy of the current sensing and control algorithms. These issues have been widely studied in the literature. This paper presents a space-vector control method for a voltage-source active...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.