A room-temperature alternating current susceptometer-Data analysis, calibration, and test

AUTHOR(S)
Alderighi, M.; Bevilacqua, G.; Biancalana, V.; Khanbekyan, A.; Dancheva, Y.; Moi, L.
PUB. DATE
December 2013
SOURCE
Review of Scientific Instruments;Dec2013, Vol. 84 Issue 12, p125105
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
An AC susceptometer operating in the range of 10 Hz to 100 kHz and at room temperature is designed, built, calibrated, and used to characterize the magnetic behaviour of coated magnetic nanoparticles. Other weakly magnetic materials (in amounts of some millilitres) can be analyzed as well. The setup makes use of a digital acquisition system in order to determine the amplitude and the phase of the sample magnetization as a function of the frequency of the driving magnetic field, which is powered by a digital waveform generator. A specific acquisition strategy makes the response directly proportional to the sample susceptibility, taking advantage of the differential nature of the coil assembly. A calibration method based on conductive samples is developed.
ACCESSION #
93390562

 

Related Articles

  • NUEVAS TÉCNICAS EN ENSAYOS NO DESTRUCTIVOS: ACFM (Alternating Current Field Measurement). Fernández, Pablo Lorenzo // DYNA - Ingeniería e Industria;mar2008, Vol. 83 Issue 2, p113 

    During last years, a lot of effort has been taken in order to find new Non Destructive Testing (NDT) methods to complement the traditional ones and try to solve their usual disadvantages. One of these new methods is the one known as ACFM (Alternating Current Field Measurement). This technique...

  • D.G. Frey and E.S. Deevey Review 1: Numerical tools in palaeolimnology — Progress, potentialities, and problems. Birks, H. J. B. // Journal of Paleolimnology;Dec1998, Vol. 20 Issue 4, p307 

    In the last decade, palaeolimnology has shifted emphasis from being a predominantly qualitative, descriptive subject to being a quantitative, analytical science with the potential to address critical hypotheses concerning the impacts of environmental changes on limnic systems. This change has...

  • MEASUREMENT OF UNCERTAINTY IN EDDY CURRENT BOLT HOLE CRACK MEASUREMENTS FOR USE IN POD. Underhill, P. R.; Krause, T. W. // AIP Conference Proceedings;2/22/2010, Vol. 1211 Issue 1, p1934 

    In order to obtain valid estimates of a90/95 for cracks in bolt holes using eddy current techniques, it is essential that an accurate model for the measurement uncertainty be used in the fit of the a-hat versus a data. In the absence of explicit error handling schemes, the use of a log axis for...

  • An Improved Design of a Fully Automated Multiple Output Micropotentiometer. Mageed, Hala Mohamed Abdel; Zobaa, Ahmed Faheem; Raouf, Mohamed Helmy Abdel; El-Rahman, Abla Hosni Abd; Aziz, Mohamed Mamdouh Abdel // Energy & Power Engineering;May2010, Vol. 2 Issue 2, p103 

    This paper describes in details a new design of a fully automated multiple output micropotentiometer (μpot). A prototype has been built at the National Institute for Standards (NIS), Egypt to establish this highly improved AC voltage source in the millivolt range. The new device offers three...

  • Calibration Curves, Part III: A Different View. Dolan, John W. // LC-GC North America;May2009, Vol. 27 Issue 5, p392 

    The article looks at the quantification of calibration curves data. It discusses some alternate ways to examine the data to highlight normal and abnormal behavior of the curve and to determine the limits of detection such as for the signal-to-noise ration (S/N). Furthermore, examples and...

  • Coming to terms with math and motors. Coyle, Timothy // Engineered Systems;Aug99, Vol. 16 Issue 8, p32 

    Discusses the concepts of alternating current (ac) circuits. Information on `ac potential'; Explanation of the three-phase power of ac power circuits; Power factor.

  • WHAT'S THE BIG DEAL ABOUT TUBE RECTIFIERS? HUNTER, DAVE // Guitar Player;Sep2013, Vol. 47 Issue 9, p136 

    The article offers the author's insights regarding the importance of tube rectifiers in guitar amplifiers for the conversion of alternating current (AC) from power transformer into direct current (DC).

  • Isn't AC More Dangerous than DC?  // Transmission & Distribution World Exclusive Insight;11/20/2014, p5 

    The article presents a question about alternating current (AC) and direct current (DC).

  • Verifying voltage. Borland, Jerry R. // EC&M Electrical Construction & Maintenance;Jun99, Vol. 98 Issue 6, p92 

    Discusses the basics of voltage and electric currents. Unit of measurement for voltage; Common ways of supplying a direct or alternating electrical currents; Voltage drop.