Perkutane Interventionen in einem offenen MR-System: Technischer Hintergrund und klinische Indikationen

AUTHOR(S)
Fischbach, F.; Fischbach, K.; Ricke, J.
PUB. DATE
November 2013
SOURCE
Der Radiologe;Nov2013, Vol. 53 Issue 11, p993
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The latest and therefore more efficient open magnetic resonance (MR) scanners with a field strength of 1 T allow freehand fluoroscopic interventions with excellent image quality. Specifically designed interactive software simplifies examination planning and performance. Guidance in two imaging planes allows fast and accurate device positioning and interventional procedures during free breathing. The diagnostic and therapeutic spectrum includes a wide variety of interstitial percutaneous interventions. The most important are periradicular therapy (PRT), intra-abdominal drainage and nephrostoma placement, biopsies, especially in the breasts and liver and focal ablation therapy of malignant hepatic or renal lesions. As the approach is fast and robotic devices are not needed the method is increasingly being carried out in the clinical routine. A drawback of MR-guided interventions is the limitation in verbal communication during image acquisition. Furthermore, the portfolio of MR compatible instruments needs to be extended.
ACCESSION #
91960703

 

Related Articles

  • Health Wise. Liberatore, Stephanie // Science Teacher;Dec2010, Vol. 77 Issue 9, p70 

    An answer is offered to a question about the difference between an x-ray, a Computerized Axial Tomography (CAT) scan, and a magnetic resonance imaging (MRI).

  • Echo Planar Diffusion-Weighted Imaging: Possibilities and Considerations with 12- and 32-Channel Head Coils. Morelli, John N.; Saettele, Megan R.; Rangaswamy, Rajesh A.; Lan Vu; Gerdes, Clint M.; Wei Zhang; Fei Ai // Journal of Clinical Imaging Science;Jan-Mar2012, Vol. 2 Issue 1, Special section p1 

    Interest in clinical brain magnetic resonance imaging using 32-channel head coils for signal reception continues to increase. The present investigation assesses possibilities for improving diffusion-weighted image quality using a 32-channel in comparison to a conventional 12-channel coil. The...

  • New perspectives and challenges in abdominal 3T MR imaging. Schoenberg, Stefan O.; Zech, Christoph J.; Panteleon, Alexandra; Michaely, Henrik J.; Finn, Paul J.; Reiser, Maximilian F. // Applied Radiology;Jan2007 Supplement, Vol. 36, p1 

    The article highlights new perspectives and challenges in abdominal 3 tesla (T) magnetic resonance imaging (MRI). The parallel acquisition techniques used on MRI systems with multiple receiver channels allow the increase of spatial resolution at almost no cost in scan time. State-of-the-art 1.5T...

  • Imaging 2.  // Multiple Sclerosis (13524585);Sep2007 Supplement 2, Vol. 13, pS177 

    The article presents abstracts of medical research which include "Subcortical nuclei atrophy in multiple sclerosis: depending on disease progression," "Measuring actual normal white matter and normal appearance white matter volume with tissue specific imaging," and "Efects of magnetic resonance...

  • In the picture. Nathan, Stuart // Engineer (00137758);3/13/2006, Vol. 293 Issue 7695, p38 

    The article reports on the development of a system known as functional magnetic resonance imaging (fMRI) by the Fraunhofer Institute for Applied Optics and Precision Engineering. It projects images of the person being scanned. Different scanning techniques are combined. A normal MRI image of the...

  • 3‐Tesla Clinical Magnetic Resonance Imaging. Tikkakoski, Tapani // Acta Radiologica;Jun2006, Vol. 47 Issue 5, p445 

    The article discusses the advantage and disadvantages of using 3-Tesla (3T) in clinical magnetic resonance imaging (MRI). The imaging system enables increased signal-to-noise ratio (SNR) and contrast-to-noise ration (CNR) which results to better resolution and faster scanning. Furthermore, it...

  • Impact of Extended Written Information on Patient Anxiety and Image Motion Artifacts During Magnetic Resonance Imaging. Törnqvist, E.; Månsson, Å.; Larsson, E.-M.; Hallström, I. // Acta Radiologica;Jun2006, Vol. 47 Issue 5, p474 

    Purpose: To evaluate whether increased written information to patients prior to magnetic resonance imaging (MRI) decreases patient anxiety and image motion artifacts. Material and Methods: A two‐group controlled experimental design was used. Of 242 patients, 118 received routinely given...

  • Volumetric computed tomography (VCT): a new technology for noninvasive, high-resolution monitoring of tumor angiogenesis. Kiessling, Fabian; Greschus, Susanne; Lichy, Matthias P.; Bock, Michael; Fink, Christian; Vosseler, Silvia; Moll, Jens; Mueller, Margareta M.; Fusenig, Norbert E.; Traupe, Horst; Semmler, Wolfhard // Nature Medicine;Oct2004, Vol. 10 Issue 10, p1133 

    Volumetric computed tomography (VCT) is a technology in which area detectors are used for imaging large volumes of a subject with isotropic imaging resolution. We are experimenting with a prototype VCT scanner that uses flat-panel X-ray detectors and is designed for high-resolution...

  • Geometric Distortion in Structural Magnetic Resonance Imaging. Wang, Deming; Doddrell, David M. // Current Medical Imaging Reviews;2005, Vol. 1 Issue 1, p49 

    Geometric distortion, an undesirable image artifact, is an inferior aspect associated with magnetic resonance imaging (MRI). Although slight distortions in MR images often have no consequences in reaching clinical conclusions, geometric distortions can make significant differences in certain MR...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics