TITLE

Frame-based radiosurgery: Is it relevant in the era of IGRT?

AUTHOR(S)
Kataria, Tejinder; Gupta, Deepak; K. P., Karrthick; Bisht, Shyam Singh; Goyal, Shikha; Abhishek, Ashu; H. B., Govardhan; Sharma, Kuldeep; Pareek, Puneet; Gupta, Aditya
PUB. DATE
May 2013
SOURCE
Neurology India;May/Jun2013, Vol. 61 Issue 3, p277
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Purpose: To assess the setup errors and intrafraction motion in patients treated with frame-based and frameless stereotactic radiosurgery (SRS). Materials and Methods: Te n patients treated with frame-based and six patients treated with frameless radiosurgery were prospectively enrolled in the study . Leksell frame was used for frame-based and a customized uniframe orfit cast for frameless techniques. Cone beam computed tomography (CBCT) scans were taken immediately before and after each treatment to evaluate the positional accuracy and corrections applied with the use of hexapod couch for both groups. Results: The mean translational shifts with frame-based SRS were 1.00 ± 0.30 mm in the lateral direction (X), 0.20 ± 1.20 mm in craniocaudal direction (Y) and -0.10 ± 0.31 mm in the anteroposterior direction (Z). The rotational shifts for frame-based treatments were as follows: roll 0.32 ± 0.70, pitch 0.44 ± 0.66 and yaw 0.20 ± 0.4. For frameless SRS, translational shifts were -0.40 ± 0.90, 1.10 ± 1.10, and 0.50 ± 1.30 mm in X, Y, and Z directions, respectively, and rotational shifts were -0.11 ± 0.78, 0.20 ± 0.44, and 0.29 ± 0.35 in roll, pitch, and yaw, respectively . Intrafraction shifts with frame-based SRS were: X = 0.60 ± 1.80 mm, Y = 0.20 ± 0.60 mm, and Z = 0.00 ± 0.05 mm; and rotational shifts were: roll 0.01 ± 0.27, pitch 0.06 ± 0.15, and yaw 0.01 ± 0.09. For frameless SRS, these were: X = 0.11 ± 0.20 mm, Y = 0.20 ± 0.40 mm, and Z = 0.20 ± 0.20 mm and rotational shifts were: roll 0.09 ± 0.23, pitch 0.00 ± 0.12, and yaw 0.00 ± 0.09. Conclusions: In our experience, set up accuracy of frameless SRS is as good as frame-based SRS. With availability of verification methods such as CBCT and hexapod couch, an accurate and precise treatment delivery is feasible with frameless techniques.
ACCESSION #
89903899

 

Related Articles

  • Percutaneous Nephrolithotomy in the 21st Century: Improvements in Instrumentation. Rizkala, Emad; Monga, Manoj // AUANews;Sep2012, Vol. 17 Issue 9, p1 

    The article discusses improvements in the instrumentation of percutaneous nephrolithomy (PCNL) in the 21st century. Flexible nephroscopy combined with high magnification fluoroscopy eliminates the need for postoperative computerized tomography. The 12Fr PERC NCircle® and the UroNet™ are...

  • Surgical Patients And The Risk Of Retained Items. Mangan, Doreen // RN;Jul2003, Vol. 66 Issue 7, p74 

    Discusses the risk of retained items on surgical patients. Unexpected changes in surgical procedures; Examination of records of claims and incident reports by researchers; Enumeration of surgical instruments retained in the patient.

  • Generation of normative pediatric skull models for use in cranial vault remodeling procedures. Saber, Nikoo; Phillips, John; Looi, Thomas; Usmani, Zoha; Burge, Jonathan; Drake, James; Kim, Peter // Child's Nervous System;Mar2012, Vol. 28 Issue 3, p405 

    Purpose: While the goal of craniofacial reconstruction surgery is to restore the cranial head shape as much towards normal as possible, for the individual patient, there is, in fact, no normal three-dimensional (3D) model to act as a guide. In this project, we generated a library of normative...

  • A technique for intraoperative creation of patient-specific titanium mesh implants. Sunderland, Ian RP; Edwards, Glenn; Mainprize, James; Antonyshyn, Oleh // Plastic Surgery;Summer2015, Vol. 23 Issue 2, p95 

    Prefabricated, patient-specific alloplastic implants for cranioplasty reduce surgical complexity, decrease operative times, minimize exposure and risk of contamination, and have resulted in improved aesthetic results. However, in creating a prefabricated custom implant using a patient's computed...

  • Minimally invasive visual systems.  // Surgical Products;Jul99, Vol. 18 Issue 8, p1 

    Features AVS Visual System, an instrument used for minimally invasive surgery by Aeseulap in South San Francisco, California.

  • Operation and anesthesia time could be reduced. Fireman // Surgical Products;Jul99, Vol. 18 Issue 8, p18 

    Examines importance of improving flow resistance in insufflation devices during laparoscopic surgery. Function of insufflation systems; Variation in insufflation systems performance; Advantages of flow and resistance optimized insufflation system in maintaining abdominal pressure; Implications...

  • Positioning Devices.  // Surgical Products;Sep2001, Vol. 20 Issue 11, p1 

    Features the PurGel OR positioning devices. Advantages of the product; Application of the device; Contact information.

  • Stent Measurement and Inspection.  // Medical Device Technology;Oct2003, Vol. 14 Issue 8, p39 

    Studies stent measurement and inspection. Features and functions of stents; Advantages provided by microscopes in stent measurement and inspection; Functions of noncontact measuring systems.

  • Literature Review: CORONARY ARTERY DISEASE--STENTS.  // Current Medical Literature: Interventional Cardiology Monitor;2004, Vol. 11 Issue 2, p44 

    Presents abstracts of research papers on the use of stents in coronary artery disease published in various periodicals.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics