TITLE

Circular magnetic bistability induced by tensile stress in glass-covered amorphous microwires

AUTHOR(S)
Chizhik, A.; Gonzalez, J.; Zhukov, A.; Blanco, J. M.
PUB. DATE
January 2003
SOURCE
Applied Physics Letters;1/27/2003, Vol. 82 Issue 4, p610
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Investigations of magnetic reversal in Co-rich glass covered amorphous microwires were performed using the magneto-optical Kerr-effect technique. The appearance of circular magnetic bistability was found in the presence of external tensile stress. A tensile-induced large Barkhausen jump of circular magnetization is associated with a change of the value of the magnetostriction constant induced by stress and by rearrangement of domain structure in the outer shell of the microwire.
ACCESSION #
8954562

 

Related Articles

  • Domain imaging and domain wall propagation in (Ga, Mn)As thin films with tensile strain. Wang, K. Y.; Rushforth, A. W.; Grant, V. A.; Campion, R. P.; Edmonds, K. W.; Staddon, C. R.; Foxon, C. T.; Gallagher, B. L.; Wunderlich, J.; Williams, D. A. // Journal of Applied Physics;5/15/2007, Vol. 101 Issue 10, p106101 

    We have performed spatially resolved polar magneto-optical Kerr effect microscopy measurements on as-grown and annealed Ga0.95Mn0.05As thin films with tensile strain. We find that the films exhibit very strong perpendicular magnetic anisotropy which is increased upon annealing. During magnetic...

  • Development of an in situ magnetoelastic magneto-optical Kerr effect magnetometer. Will, I. G.; Ding, A.; Xu, Y. B. // Review of Scientific Instruments;Jun2012, Vol. 83 Issue 6, p064707 

    Reported here is the development and implementation of an integrated in situ magnetoelastic measurement setup with a MOKE magnetometer, repositionable electromagnet, and sample transfer/straining device. The former were used within a molecular beam epitaxial vacuum growth chamber. Consequently...

  • Thickness-dependent converse magnetoelectric coupling in bi-layered Ni/PZT thin films. Li, Zheng; Hu, Jiamian; Shu, Li; Gao, Ya; Shen, Yang; Lin, Yuanhua; Nan, C. W. // Journal of Applied Physics;Feb2012, Vol. 111 Issue 3, p033918 

    The converse magnetoelectric (ME) effect was investigated in bi-layered Ni/Pb(Zr0.52Ti0.48)O3 (PZT) thin films grown on Si substrates, with different thicknesses of Ni thin layers. By using an AC-mode magneto-optical Kerr effect method, it was revealed that the electric-voltage induced...

  • Perpendicular magnetic anisotropy and magneto-optical Kerr effect of vapor-deposited Co/Pt-layered structures. Zeper, W. B.; Greidanus, F. J. A. M.; Carcia, P. F.; Fincher, C. R. // Journal of Applied Physics;6/15/1989, Vol. 65 Issue 12, p4971 

    Presents a study which examined the perpendicular magnetic anisotropy and magneto-optical Kerr effect of vapor-deposited cobalt/platinum-layered structures. Interface contribution to the anisotropy; Magneto-optical polar Kerr effect of these multilayers; Discussion.

  • Out-of-plane exchange coupling between epitaxial Ni (50 Ã…) and NiO (600 Ã…) bilayers. Liu, Z. Y.; Adenwalla, S. // Journal of Applied Physics;2/15/2003, Vol. 93 Issue 4, p2091 

    We have investigated the exchange coupling between an epitaxial Ni (50 Ã…) film with an out-of-plane magnetic easy axis and a NiO (600 Ã…) film by polar magneto-optic Kerr-effect measurements. The temperature dependences of exchange field H[sub E], for both as-deposited and field-cooled...

  • Design and performance of magneto-optic enhanced Co/Pt-based trilayers having zero Kerr ellipticity. Atkinson, R.; Grundy, P. J.; Hanratty, C. M.; Pollard, R. J.; Salter, I. W. // Journal of Applied Physics;5/15/1994, Vol. 75 Issue 10, p6861 

    Presents information on a study that outlined the design philosophy and objectives for producing phase-optimized trilayer structures for magneto-optic enhancement of the polar Kerr effect. Experimental procedure; Theoretical results; Conclusion.

  • Surface magneto-optic Kerr effect. Qiu, Z. Q.; Qiu, Z.Q.; Bader, S. D.; Bader, S.D. // Review of Scientific Instruments;Mar2000, Vol. 71 Issue 3 

    The surface magneto-optic Kerr effect (SMOKE) has significantly impacted research on magnetic thin films. This is due to its sensitivity, local probing nature, and experimental simplicity. The polar and longitudinal Kerr effects are characterized by a complex rotation of the plane of...

  • Three-configurational surface magneto-optical Kerr effect measurement system for an ultrahigh vacuum in situ study of ultrathin magnetic films. Lee, J.-W.; Jeong, J.-R.; Jeong, J.R.; Kim, D.-H.; Ahn, J. S.; Ahn, J.S.; Kim, J.; Shin, S.-C. // Review of Scientific Instruments;Oct2000, Vol. 71 Issue 10 

    We have constructed a three-configurational surface magneto-optical Kerr effect system, which provides the simultaneous measurements of the "polar," "longitudinal," and "transverse" Kerr hysteresis loops at the position where deposition is carried out in an ultrahigh vacuum growth chamber. The...

  • The effect of transition from a crystalline to amorphous structure on the magneto-optical Kerr... Cai, J.H.; Gu, G. // Journal of Applied Physics;5/1/1999, Vol. 85 Issue 9, p6797 

    Focuses on a study concerning the structure, optical constant effect, and magneto-optical Kerr rotation in iron-cobalt-silicon films. Experimental details; Details on Kerr rotation spectra; Conclusions.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library