TITLE

Anomalous hard x-ray emission mode in a plasma focus discharge with hydrogen-argon mixtures

AUTHOR(S)
Heo, Hoon; Park, Duck Kyu
PUB. DATE
January 2003
SOURCE
Applied Physics Letters;1/20/2003, Vol. 82 Issue 3, p340
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We observed an anomalous discharge mode causing explosive surface evaporation and emission of hard x rays of 10-40 keV in the regime of the lower hydrogen partial pressures of hydrogen-argon mixture in a Mather type plasma focus device of 1.5 kJ. At the anomalous mode, the x rays were emitted from only the surface of the anode without emissions from a plasma column or hot spots, accompanying with explosive evaporations of the anode surface.
ACCESSION #
8926084

 

Related Articles

  • Studies of the distribution of the Z-pinch radiance during the implosion of wire arrays in the angara-5-1 facility. Grabovskii, E. V.; Oleinik, G. M.; Porofeev, I. Yu. // Plasma Physics Reports;Jun2006, Vol. 32 Issue 6, p475 

    Results are presented from time-integrated measurements of soft X-ray emission from Z-pinches during the implosion of simple and nested wire arrays. The blackening density distribution obtained with the help of a pinhole camera is recalculated into the time-integrated Z-pinch radiance. It is...

  • Toward ultrafast time-resolved Debye–Scherrer x-ray diffraction using a laser-plasma source. Shymanovich, U.; Nicoul, M.; Lu, W.; Kähle, S.; Tarasevitch, A.; Sokolowski-Tinten, K.; von der Linde, D. // Review of Scientific Instruments;Aug2009, Vol. 80 Issue 8, p083102 

    An elliptical glass capillary has been used to focus ultrashort Cu Kα x-ray pulses emitted from a femtosecond laser-produced plasma. Due to its high magnification (7×), the optic transforms the divergent x-ray emission of the plasma into a quasicollimated x-ray beam with a divergence of...

  • Measurement of the high energy component of the x-ray spectra in the VENUS electron cyclotron resonance ion source. Leitner, D.; Benitez, J. Y.; Lyneis, C. M.; Todd, D. S.; Ropponen, T.; Ropponen, J.; Koivisto, H.; Gammino, S. // Review of Scientific Instruments;Mar2008, Vol. 79 Issue 3, p033302 

    High performance electron cyclotron resonance (ECR) ion sources, such as VENUS (Versatile ECR for NUclear Science), produce large amounts of x-rays. By studying their energy spectra, conclusions can be drawn about the electron heating process and the electron confinement. In addition, the...

  • Microanalysis by monochromatic microprobe x-ray fluorescence -physical basis, properties, ... Chen, Z.W.; Wittry, D.B. // Journal of Applied Physics;7/15/1998, Vol. 84 Issue 2, p1064 

    Presents an microanalysis on the physical basis, properties of monochromatic microprobe x-ray fluorescene (MMXRF). Discussion on the experimental parameters of MMXRF; Characterization of the mica diffractor; Description of the diffraction and properties of the mica diffractor and the...

  • The X-ray source populations of the magellanic clouds. Haberl, F. // AIP Conference Proceedings;2001, Vol. 599 Issue 1, p449 

    ROSAT performed about 250 PSPC observations pointed towards the Magellanic Clouds (MCs). A systematic analysis of the data yielded catalogues with more than 750 X-ray sources in the LMC and about 520 in the SMC region. Cross-correlations with catalogues from various other wavelength bands and...

  • X-rays with the Midas touch. Franklin, Carl // New Scientist;7/17/93, Vol. 139 Issue 1882, p21 

    Reports on KX Technology's Goldstream analyser which can accurately detect gold in a ton of ore. Measurement of solid and dissolved gold; On-stream analyser; X-ray fluorescence spectrometry.

  • Microchannel-plate intensified crystal spectrometer for use in soft x-ray spectroscopy. Hailey, C. J.; Rockett, P.; Eckart, M.; Burkhalter, P. G. // Review of Scientific Instruments;Aug1985, Vol. 56 Issue 8, p1553 

    A Bragg crystal spectrometer, utilizing a microchannel plate coupled to optical film as the detection medium, has been constructed for use in soft x-ray spectroscopy. The sensitivity of this intensified gated camera to x-rays has been compared directly with standard x-ray film using a calibrated...

  • Two-channel, elliptical analyzer spectrograph for absolute, time-resolving time-integrating spectrometry of pulsed x-ray sources in the 100–10 000-eV region. Henke, B. L.; Jaanimagi, P. A. // Review of Scientific Instruments;Aug1985, Vol. 56 Issue 8, p1537 

    A new spectrographic system has been developed and calibrated in this laboratory for the absolute spectrometry of high-intensity pulsed x-ray sources in the 100–10 000-eV region. This spectral region is analyzed with fixed elliptically curved crystals and molecular or...

  • X-ray fluorescence analysis of lead in bone Landrigan, Philip J.; Todd, Andrew C. // Environmental Health Perspectives;Nov1993, Vol. 101 Issue 6, p494 

    No abstract available.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics