ABSTRACT
It is shown that a multigap resistive plate chamber made of commercial float glass is capable of sustaining high counting rates at an increased operating temperature. Two glass chambers were investigated on the test beamline of the U-70 accelerator at the Institute for High Energy Physics. The required radiation flux density at the detector was produced by means of radioactive sources. The time resolution of 80 ps or better was attained at a rate of ∼20 kHz/cm and an operating temperature of 45°C.
ACCESSION #
88060367

 

Related Articles

  • Development of a Tracking System of Exotic Nuclear Beams for FAIR. Fernández, B.; Pancin, J.; Abou-Haidar, Z.; Alvarez, M. A. G.; Drouart, A.; Kebbiri, M.; Riallot, M. // AIP Conference Proceedings;4/26/2010, Vol. 1231 Issue 1, p219 

    New accelerators like SPIRAL2 (GANIL, France) or FAIR (GSI, Germany) will be soon constructed, and they will be able to produce radioactive ion beams (RIB) with high intensities of current (>=106 pps). These beams, at low energy, lower than 20 MeV/n, usually have high emittance, which imposes...

  • Transfer Reactions on Neutron-rich Nuclei at REX-ISOLDE. Kröll, Th.; Bildstein, V.; Wimmer, K.; Krücken, R.; Gernhäuser, R.; Lutter, R.; Schwerdtfeger, W.; Thirolf, P.; Bastin, B.; Bree, N.; Diriken, J.; Huyse, M.; Patronis, N.; Raabe, R.; Van Duppen, P.; Vermaelen, P.; Cederkäll, J.; Clément, E.; Van de Walle, J.; Voulot, D. // AIP Conference Proceedings;8/26/2009, Vol. 1165 Issue 1, p363 

    We report on one- and two-neutron transfer reactions to study the single-particle properties of nuclei at the border of the “island of inversion.” The (d, p)- and (t, p)-reactions in inverse kinematics on the neutron-rich isotope 30Mg, delivered as radioactive beam by the REX-ISOLDE...

  • ISOMERIC RATIO FOR THE IÏ€ = 8+ YRAST STATE IN 96Pd PRODUCED IN THE RELATIVISTIC FRAGMENTATION OF 107Ag. Myalski, S.; Kmiecik, M.; Maj, A.; Regan, P. H.; Garnsworthy, A. B.; Pietri, S.; Rudolph, D.; Podolyák, Zs.; Steer, S. J.; Becker, F.; Bednarczyk, P.; Gerl, J.; Górska, M.; Grawe, H.; Kojouharov, I.; Schaffner, H.; Wollersheim, H. J.; Prokopowicz, W.; Grębosz, J.; Benzoni, G. // Acta Physica Polonica B;2007, Vol. 38 Issue 4, p1277 

    We report on the preliminary results from a study of the decay of the Iπ = 8+ T½ = 2µs isomer in 96Pd performed as part of the Stopped-Beam RISING campaign within the Rare Isotope Investigation at GSI (RISING). The 96Pd ions were produced following the projectile fragmentation of a 750...

  • Recent Activities in Tandem, Booster and TRIAC at Tokai. Ishii, Tetsuro; Matsuda, Makoto; Kabumoto, Hiroshi; Osa, Akihiko // AIP Conference Proceedings;5/4/2009, Vol. 1120 Issue 1, p235 

    Present status and recent developments of the tandem accelerator, superconducting booster, and radioactive nuclear beam accelerator TRIAC are presented. The terminal voltage of the tandem accelerator reached 19.1 MV by replacing acceleration tubes. The multi-charged positive-ion injector was...

  • High energy beta beams without massive detectors. Terranova, F.; Marotta, A.; Migliozzi, P.; Spinetti, M. // European Physical Journal C -- Particles & Fields;Dec2004, Vol. 38 Issue 1, p69 

    In this paper, the possibility to exploit a high energy beta beam without massive detectors is discussed. The radioactive ions are boosted up to very highwith the neutrino beam pointing towards an instrumented surface located at a moderate baseline (e.g. from CERN to the Gran Sasso...

  • The TRIUMF-ISAC gamma-ray escape suppressed specrometer, TIGRESS. Hackman, G.; Svensson, C. E. // Hyperfine Interactions;Feb2014, Vol. 225 Issue 1-3, p241 

    The TRIUMF-ISAC Gamma-Ray Escape Suppressed Spectrometer is a high energy-resolution, high efficiency γ-ray detector array for radioactive beam experiments. It consists of high-purity germanium detectors with scintillator suppressors and waveform digitization. TIGRESS can operate in modes...

  • First Decay Spectroscopy Experiment at RIBF. Nishimura, S. // AIP Conference Proceedings;8/12/2010, Vol. 1269 Issue 1, p91 

    A first RIBF experiment for decay spectroscopy was performed. Neutron-rich nuclei with mass number A ∼ 110 were produced using in-flight fission of 238U. A new beta-counting system consisting of nine layers of double-sided-silicon-strip detector (DSSSD) was employed to detect beta-rays from...

  • Testing the standard model of nuclear physics. Tabor, S. L.; Bender, P. C. // AIP Conference Proceedings;2/29/2012, Vol. 1423 Issue 1, p15 

    Shell model calculations using optimized effective interactions are becoming the standard model of nuclear structure physics. While earlier effective interactions were optimized for nuclei near the valley of stability, radioactive beam facilities have allowed the study of nuclei much farther...

  • Diagnostics for radioactive beams. Laune´, B. // AIP Conference Proceedings;2001, Vol. 600 Issue 1, p359 

    The interest of generating and accelerating beams of unstable nuclei is continuously growing. Following pioneers, new facilities are put into operation or planned. In order to obtain and maintain the highest efficiency, dedicated diagnostics tools have to be developed. The specificities of such...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics