TITLE

Total absorption γ-ray spectroscopy of beta delayed neutron emitters

AUTHOR(S)
Valencia, E.; Algora, A.; Tain, J. L.; Rice, S.; Agramunt, J.; Zakari-Issoufou, A.-A.; Porta, A.; Fallot, M.; Jordan, M. D.; Molina, F.; Estevez, E.; Bowry, M.; Bui, V. M.; Caballero-Folch, R.; Cano-Ott, D.; Eloma, V.; Eronen, T.; Garcia, A.; Gomez-Hornillos, M. B.; Gorlychev, V.
PUB. DATE
June 2013
SOURCE
AIP Conference Proceedings;Jun2013, Vol. 1541 Issue 1, p161
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Preliminary results of the data analysis of the beta decay of 94Rb using a novel - segmented- total absorption spectrometer are shown in this contribution. This result is part of a systematic study of important contributors to the decay heat problem in nuclear reactors. In this particular case the goal is to determine the beta intensity distribution below the neutron separation energy and the gamma/beta competition above.
ACCESSION #
88057074

 

Related Articles

  • Characterization of a new modular decay total absorption gamma-ray spectrometer (DTAS) for FAIR. Pizá, A. Montaner; Taín, J. L.; Agramunt, J.; Algora, A.; Guadilla, V.; Marín, E.; Rice, S.; Rubio, B. // AIP Conference Proceedings;Jun2013, Vol. 1541 Issue 1, p179 

    Beta-decay studies are one of the main goals of the DEcay SPECtroscopy experiment (DESPEC) to be installed at the future Facility for Antiproton and Ion Research (FAIR). DESPEC aims at the study of nuclear structure of exotic nuclei. A new modular Decay Total Absorption gamma-ray Spectrometer...

  • Components of Antineutrino Emission in Nuclear Reactor. Kopeikin, V. I.; Mikaelyan, L. A.; Sinev, V. V. // Physics of Atomic Nuclei;Nov2004, Vol. 67 Issue 11, p1963 

    New νee scattering experiments aimed at sensitive searches for the νe magnetic moment and projects to explore small mixing angle neutrino oscillations at reactors require a better understanding of the reactor antineutrino spectrum. Six components which contribute to the total νe...

  • On the reassessment of thermal neutron doses in TLD-100 by measuring the residual dose. Abraham, A.; Weinstein, M.; German, U.; Alfassi, Z. B. // Radiation Protection Dosimetry;Aug2007, Vol. 126 Issue 1-4, p524 

    By employing second readouts and the Phototransferred thermoluminescence (PTTL) method, high doses may be reassessed on the basis of residual dose information. It was shown in the past that for TLD-100, gamma doses can be reassessed by using a simple and efficient method, which consists of...

  • Characterisation of neutron fields at Cernavoda NPP. Cauwels, Vanessa; Vanhavere, Filip; Dumitrescu, Dorin; Chirosca, Alecsandru; Hager, Luke; Million, Marc; Bartz, James // Radiation Protection Dosimetry;Apr2013, Vol. 154 Issue 1, p104 

    Near a nuclear reactor or a fuel container, mixed neutron/gamma fields are very common, necessitating routine neutron dosimetry. Accurate neutron dosimetry is complicated by the fact that the neutron effective dose is strongly dependent on the neutron energy and the direction distribution of the...

  • Characteristics of neutron and gamma radiation in the core of the ΦC-1-4.37.P critical assembly. Sevast’yanov, V.; Nikolaev, S.; Somov, I.; Shesterkin, A.; Chernov, V.; Volkov, V.; Kas’yan, A.; Masterov, A.; Moseev, V. // Instruments & Experimental Techniques;Jul2007, Vol. 50 Issue 4, p444 

    The characteristics of neutron and γ-ray fields (spectrum, flux density, average energy, cross sections of 23 nuclear reactions, and γ-ray dose rate) and the γ-ray field in the core of the ΦC-1-4.37.P critical assembly of the ΦC-1M critical bench are determined. The results of...

  • Application of GRS method to evaluation of uncertainties of calculation parameters of perspective sodium-cooled fast reactor. Peregudov, A.; Andrianova, O.; Raskach, K.; Tsibulya, A. // EPJ Web of Conferences;2013, Issue 42, p07002-p.1 

    The article focuses on the use of Gamma-Ray Spectrometer (GRS) method to calculate the uncertainties of calculation parameters of the sodium-cooled fast reactors. It mentions that the calculation errors due changes in neutron data and technological parameters including geometrical and material...

  • Is the k0 method accurate for elements with high Q0 values? Kennedy, G.; St-Pierre, J. // Journal of Radioanalytical & Nuclear Chemistry;Sep2003, Vol. 257 Issue 3, p475 

    With a SLOWPOKE reactor, activation by epithermal neutrons is more important than for most other reactors. It was therefore undertaken to verify the accuracy of the k0 method for all elements with high Q0 values. Accurate standards of 40 elements were prepared and irradiated in the inner and...

  • Analysis of SMELS by k-based IM-NAA method using PFTS position of KAMINI reactor for quality control exercise. Swain, K.; Acharya, R.; Reddy, A. // Journal of Radioanalytical & Nuclear Chemistry;Apr2014, Vol. 300 Issue 1, p33 

    As a part of QA/QC of k-based internal monostandard neutron activation analysis (IM-NAA), three types of synthetic multielement standards (SMELS) were analyzed using pneumatic fast transfer system irradiation position of KAMINI reactor, IGCAR. Radioactive assay of activation products was carried...

  • DESCANT — the deuterated scintillator array for neutron tagging. Garrett, P. E. // Hyperfine Interactions;Feb2014, Vol. 225 Issue 1-3, p137 

    The DESCANT array is a new device for neutron detection based on deuterated liquid scintillator. It has been designed to be coupled with the TIGRESS and GRIFFIN γ-ray spectrometers to enable neutron tagging in fusion-evaporation reactions, and β-delayed neutron studies.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics