TITLE

Calibration of a DSSSD detector with radioactive sources

AUTHOR(S)
Guadilla, V.; Taín, J. L.; Agramunt, J.; Algora, A.; Domingo-Pardo, C.; Rubio, B.
PUB. DATE
June 2013
SOURCE
AIP Conference Proceedings;Jun2013, Vol. 1541 Issue 1, p173
SOURCE TYPE
Conference Proceeding
DOC. TYPE
Article
ABSTRACT
The energy calibration of a DSSSD is carried out with the spectra produced by a 207Bi conversion electron source, a 137Cs gamma source and a 239Pu/241Am/244Cm triple alpha source, as well as employing a precision pulse generator in the whole dynamic range. Multiplicity and coincidence of signals in different strips for the same event are also studied.
ACCESSION #
88057054

 

Related Articles

  • Detector Efficiency Calibration for Extended Gamma-Ray Sources. dos Santos, Roberto M.; Genezini, Frederico A.; Zahn, Guilherme S. // AIP Conference Proceedings;8/10/2011, Vol. 1351 Issue 1, p220 

    A new method for the efficiency calibration of Ge detectors efficiency in measurements with large sources is proposed. To check the reliability of the method, a standard large source was produced and the results are compared to the ones obtained using the proposed method. The preliminary results...

  • Method to calibrate an ionization chamber for measuring indoor radon concentrations with standard gamma-ray sources. Matsumoto, Yuzuru; Tokumori, Kenji; Iwata, Toru; Sakae, Takeji; Ishibashi, Kenji; Katase, Akira // Review of Scientific Instruments;Jun89, Vol. 60 Issue 6, p1189 

    Most instruments for measuring radon concentrations in the air should be calibrated using air with known radon concentrations, obtained from a solution of radium. However, safe handling of such a solution of alpha-active elements can be troublesome. Standard gamma-ray sources of low activity are...

  • The calculation of the detection efficiency in the calibration of gross alpha-beta systems. Calin, Marian; Druker, Alexandru; Radulescu, Ileana // Journal of Radioanalytical & Nuclear Chemistry;Jan2013, Vol. 295 Issue 1, p283 

    This paper presents a method for efficiency calibration of a measuring alpha-beta system PROTEAN ORTEC, MPC-2000-DP, using standard radioactive sources. The system is used to measure gross alpha-beta activity concentrations in environmental samples. The calculated efficiencies of detection were...

  • A comparison study on three different radiation detectors used for liquid levelmetry. Ghorbani, P.; Bayat, E.; Ghal-Eh, N. // Radiation Protection Dosimetry;Aug2013, Vol. 156 Issue 1, p103 

    In this paper, three different radiation detectors (BF3 counter, NE213 and BGO scintillators) and an 241Am–Be isotopic neutron–gamma source have been used for a typical liquid levelmetry. The study shows that the use of the Am–Be source together with an NE213 scintillator...

  • Spectral Multi-peak Analysis Methodology for Eliminating Effects of NaI Temperature Drift. Uckan, Taner; March-Leuba, José; Brukiewa, Patrick; Upadhyaya, Belle R. // Proceedings of the Institute of Nuclear Materials Management Ann;2010, p1 

    This paper presents a methodology of spectral multi-peak analysis for eliminating temperature drift effects of NaI scintillation gamma-ray detectors. Properties and cost of NaI make it an excellent choice for low energy (< 1-MeV) spectroscopic studies. However, the light output of NaI...

  • Using Quasi-Monoenergetic Photon Sources To Probe Photo-Fission Resonances. Johnson, Micah S.; Hall, James M.; McNabb, Dennis P.; Tuffley, Michael J.; Ahmed, Mohammed W.; Stave, Sean; Weller, Henry R.; Karwowski, Hugon; Thompkins, Jeromy // AIP Conference Proceedings;6/1/2011, Vol. 1336 Issue 1, p590 

    We present preliminary results of photo-fission measurements of uranium isotopes with the quasi-monoenergetic gamma-ray source, HIGS. The measurements were performed to search for photo-fission resonances. We discuss potential applications to use photo-fission resonances to identify special...

  • Development of High Gradient Laser Wakefield Accelerators Towards Nuclear Detection Applications at LBNL. Geddes, Cameron G. R.; Bruhwiler, David L.; Cary, John R.; Esarey, Eric H.; Gonsalves, Anthony J.; Lin, Chen; Cormier-Michel, Estelle; Matlis, Nicholas H.; Nakamura, Kei; Bakeman, Mike; Panasenko, Dmitriy; Plateau, Guillaume R.; Schroeder, Carl B.; Toth, Csaba; Leemans, Wim P. // AIP Conference Proceedings;3/15/2009, Vol. 1099 Issue 1, p666 

    Compact high-energy linacs are important to applications including monochromatic gamma sources for nuclear material security applications. Recent laser wakefield accelerator experiments at LBNL demonstrated narrow energy spread beams, now with energies of up to 1 GeV in 3 cm using a plasma...

  • Processing of data from a global atmospheric radioactivity monitoring network for CTBT verification purposes. Matthews, K.M.; De Geer, L-E. // Journal of Radioanalytical & Nuclear Chemistry;Jan2005, Vol. 263 Issue 1, p235 

    Finland has the operational capability to take airborne gamma-ray measurements in emergency situations. The original purpose of airborne radiation mapping in Finland was to identify hazardous areas containing radioactive fall-out after a nuclear accident or use of nuclear weapons. Regular...

  • METHODOLOGY OF TESTING VEHICLE RADIATION PORTAL MONITORS CONSIDERING FIELD OPERATION CONDITIONS. Kagan, Leonid; Stavrov, Andrei // Proceedings of the Institute of Nuclear Materials Management Ann;2010, p1 

    The problem discussed deals with testing radiation portal monitors with due account for two causes considerably complicating the detection of gamma sources by vehicle and train radiation portal monitors under field operation conditions: (i) gamma radiation shielding by materials transported in a...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics