LIU Hongwei; GU Weidong; SUN Junying
May 2013
Chinese Journal of Reparative & Reconstructive Surgery;May2013, Vol. 27 Issue 5, p594
Academic Journal
No abstract available.


Related Articles

  • Cementless Total Hip Arthroplasty with a Tapered, Rectangular Titanium Stem and a Threaded Cup. Grübl, Alexander; Chiari, Catharina; Gruber, Martin; Kaider, Alexandra; Gottsauner-Wolf, Florian // Journal of Bone & Joint Surgery, American Volume;Mar2002, Vol. 84-A Issue 3, p425 

    Focuses on the cementless hip arthroplasties with tapered, rectangular titanium stem and a threaded cup. Use of a modified transgluteal approach; Dimensions of anteroposterior radiographs; Outcome of femoral components.

  • Total hip arthroplasty with satin finish, tapered stems. Ritter, Merrill A.; Harty, Leesa D.; Lorenzo, Rodrigo A.; Lutgring, Joseph D. // Orthopedics;Dec2005, Vol. 28 Issue 12, p1454 

    Subsidence of femoral hip prostheses with a rough surface has been associated with osteolysis and loosening. However, recent evidence has suggested that smooth-finish tapered stems may not incur these problems. An experimental monobloc satin finish, tapered femoral component was designed to...

  • Effect of Hip Stem Taper on Cement Stresses. New, A. M. R.; Taylor, M.; Wroblewski, B. M. // Orthopedics;Aug2005 Supplement, Vol. 28, ps857 

    The aim of this study was to use finite element models to investigate the effect of the design of the taper of polished, collarless, total hip replacement femoral components on stresses in the cement mantle surrounding the component. A single-taper prosthesis, double-taper prosthesis, and...

  • Dissociation of a Morse-Taper Stemmed Tibial Component Following Revision Total Knee Arthroplasty. Kennedy, John G.; Kearns, Stephen R.; Quinlan, William B. // Journal of Bone & Joint Surgery, American Volume;Mar2003, Vol. 85-A Issue 3, p536 

    Discusses the case of a patient whose Morse taper failed during revision total knee arthroplasty. Replacement of both the femoral and tibial component; Preparation of the tibial metaphysis; Achievement of a circumferential mantle between prosthesis and the bone.

  • Long-Term Follow-Up Results of a Second-Generation Cementless Femoral Prosthesis with a Collar and Straight Distal Fixation Channels. Chang Wook Han; Ick Hwan Yang; Hye Yeon Lee; Chang Dong Han // Yonsei Medical Journal;1/1/2012, Vol. 53 Issue 1, p186 

    Purpose: We evaluated the results of more than 10 years of follow-up of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels. Materials and Methods: One hundred five patients (129 hips) who underwent surgery between...

  • Characteristic loosening of the distally straight cylindrical femoral stem. Kimura, Gota; Onishi, Eijiro; Kawanabe, Keiichi; Kazutaka, So; Tsukanaka, Masako; Akiyama, Haruhiko // Journal of Orthopaedic Science;May2014, Vol. 19 Issue 3, p437 

    Background: The cemented femoral stem with a distally straight cylindrical shape was designed to fill the distal femoral canal to facilitate higher cement pressurization and stability. We examined the mid-term outcomes of a stem made of titanium alloy and the efficacy of this shape. Methods:...

  • The Cementless Spotorno stem in THA: 10 year results. Takuma Yamasaki; Yuji Yasunaga; Ryo Mori; Michio Hamanishi; Takeshi Shoji; Mitsuo Ochi // Hip International;2014, Vol. 24 Issue 1, p98 

    Background: The clinical results of total hip arthroplasty (THA) with a cementless prosthesis have been constantly improving due to progress in the area of stem design and surface finish. Cementless Spotorno stem (CLS stem; Zimmer, Warsaw, USA) is a double-tapered rectangular straight stem. The...

  • Fixation of the Cemented Stem: Clinical Relevance of the Porosity and Thickness of the Cement Mantle. Hernigou, Philippe; Daltro, Gildasio; Lachaniette, Charles Henri Flouzat; Roussignol, Xavier; Mukasa, Martin Mukisi; Poignard, Alexandre // Open Orthopaedics Journal;2009, Vol. 3, p8 

    The aim of this review paper is to define the fixation of the cemented stem. Polymethyl methacrylate, otherwise known as "bone cement", has been used in the fixation of hip implants since the early 1960s. Sir John Charnley, the pioneer of modern hip replacement, incorporated the use of cement in...

  • Revision Hip Arthroplasty in Patients With a Previous Total Hip Replacement for Osteonecrosis of the Femoral Head. Park, Youn-Soo; Moon, Young-Wan; Lee, Keun-Ho; Lim, Seung-Jae // Orthopedics;Dec2014, Vol. 37 Issue 12, pe1058 

    Full article available online at Healio.com/Orthopedics Patients with osteonecrosis of the femoral head are typically relatively young and active and often require high rates of revision after primary total hip arthroplasty. However, outcomes of revision hip arthroplasty in this patient...

  • Severe Wear and Pseudotumor Formation Due to Taper Mismatch in a Total Hip Arthroplasty. Koper, M. C.; Mathijssen, N. M. C.; Witt, F.; Morlock, M. M.; Vehmeijer, S. B. W. // Case Connector;Apr-Jun2015, Vol. 5 Issue 2, p1 

    Case: We describe the case of a seventy-six-year-old woman who had undergone bilateral total hip arthroplasty with Zweymüller-Metasul prostheses in 1996. After a fall sixteen years after the index procedures, radiographs suggested a taper fracture of the left total hip arthroplasty. However,...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics