TITLE

Performance Improvement of a Roof Top Air-Conditioning Unit by Refrigerant Circuitry Optimization

AUTHOR(S)
Lee, Sunil; Yashar, David A.; Domanski, Piotr A.
PUB. DATE
January 2013
SOURCE
ASHRAE Transactions;2013, Vol. 119 Issue 1, Special section p1
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
In this experiment-aided simulation study, we achieved the performance improvement of a Roof Top Unit (RTU) by optimizing an evaporator's refrigerant circuitry using evolutionary algorithms. The system used in this study was a 2-stage 7.5 Ton RTU with an air-to-refrigerant finned-tube evaporator consisting of 144 rifled tubes divided amongst 16 circuits. The RTU was designed to operate as an air- to-air heat pump, but was modified with water-cooled condensers for the purpose of testing. Performance tests were conducted in an environmental chamber in line with AHRI standard 340/360 (2007) by maintaining the liquid line saturation temperature and subcooling from the manufacturer's test data by adjusting the condenser water flow rate and temperature. We measured the capacity of the original design included in the RTU to be 26.4 kW (90 100 Btu/h). We also measured the in-situ air velocity profile under test condition using Particle Image Velocimetry (PIV), a non-intrusive, laser-based technique. The results of the PIV measurements uncovered several non-uniformities in the air velocity profile due to the blower location, the condensation drip tray, the placement of the air filter racks, and the position and orientation of the heat exchanger within the unit. The measurements showed that the range of air velocities passing through the heat exchanger varied from 0.5 m/s (1.64 ft/s) to 3.0 m/s (9.84 ft/s), with the integrated average of the measurements being 1.75 m/s (5.74 ft/s). We simulated the performance of the original evaporator operating with the measured air velocity profile using NIST's heat exchanger program, EVAP-COND. We matched the simulation results to the measured data by selecting appropriate correction factors for the refrigerant heat transfer coefficient, refrigerant pressure drop, and air-side heat transfer coefficient. We then used this model to optimize the evaporator circuitry using the evolutionary algorithm based module embedded in the program. The optimization process resulted in a design with a simulated capacity of 28.5 kW (97 200 Btu/h), nearly 8% higher than the original design.
ACCESSION #
87646202

 

Related Articles

  • Investigation of Electric and Reverse-Cycle Hot-Gas Defrosting for Evaporators in Refrigeration Systems. Zahid, S.; Rizvi, H. // ASHRAE Transactions;2013, Vol. 119 Issue 1, Special section p1 

    This paper investigates the performance of evaporator heat exchangers' defrosting methodology for refrigeration systems. The electric defrosting method for evaporators is often utilized for relatively small systems below 20 kW(5.7 TR) and with direct-expansion (DX) evaporators operating at...

  • Microchannel Heat Exchangers. Westphalen, Detlef; Roth, Kurt W.; Brodrick, James // ASHRAE Journal;Dec2003, Vol. 45 Issue 12, p107 

    Focuses on microchannel heat exchangers (MCHX). Description and mechanics; Potential for more cost-effective increases in the efficiency of an air-conditioning unit; Design challenges of MCHX.

  • The Experiment on System Performance Comparing Analysis and Displacement between R1270 and R22. Wu Zhijiang // Applied Mechanics & Materials;2015, Vol. 799-800, p770 

    The refrigeration circle performance of air conditioning comparing analysis and displacement between R1270 and R22 is studied in this paper. In addition, the system performance optimization of R1270 refrigeration circle is discussed. The experimental results show that the smaller tube diameter...

  • Optimization of R507A-R23 Cascade Refrigeration System using Genetic Algorithm. Parekh, A. D.; Tailor, P. R.; Jivanramajiwala, H. R. // World Academy of Science, Engineering & Technology;Nov2010, Issue 47, p4 

    No abstract available.

  • DIAGNOSTICS AND OPTIMIZATION OF A MINIATURE HIGH FREQUENCY PULSE TUBE CRYOCOOLER. Garaway, I.; Veprik, A.; Radebaugh, R. // AIP Conference Proceedings;4/9/2010, Vol. 1218 Issue 1, p167 

    A miniature, high energy density, pulse tube cryocooler with an inertance tube and reservoir has been developed, tested, diagnosed and optimized to provide appropriate cooling for size-limited cryogenic applications demanding fast cool down. This cryocooler, originally designed using REGEN 3.2...

  • Thermally Active Floors. Nall, Daniel H. // ASHRAE Journal;Feb2013, Vol. 55 Issue 2, p36 

    The article discusses the application of thermally active floor system using the Engineering Equation Solver and the heat exchange algorithms provided by the American Society of Heating, Refrigerating and Air-Conditioning Engineers. The other tools used in evaluating the pattern of solar...

  • HEAT AND GAS SUPPLY, VENTILATION, AIR CONDITIONING, GAS SUPPLY AND ILLUMINATION. Golovinsky, P. A. // Scientific Herald of the Voronezh State University of Architectu;2011, Vol. 10 Issue 2, p28 

    Background. Interest in the problem of network reliability increased rapidly owing to the new field of application, including computer and transport networks, as well as social and innovation networks. Models and algorithms of analysis of network destruction dynamics are not sufficiently...

  • Approximation-Assisted Optimization for Novel Compact Heat Exchanger Designs. Abdelaziz, Omar; Aute, Vikrant; Azarm, Shapour; Radermacher, Reinhard // HVAC&R Research;Sep2010, Vol. 16 Issue 5, p707 

    This paper describes a systematic approach for the use of an approximation-assisted optimization technique in the design of a novel heat exchanger (HX) with a high degree of model fidelity and a low computational cost. Design optimization is performed using multiobjective optimization, and high...

  • Various criteria in optimization of a geothermal air conditioning system with a horizontal ground heat exchanger. Sayyaadi, Hoseyn; Amlashi, Emad Hadaddi // International Journal of Energy Research;Mar2010, Vol. 34 Issue 3, p233 

    Thermodynamic and thermoeconomic optimization of a horizontal geothermal air conditioning system has been performed. A model based on energy and exergy analysis is presented here. An economic model of the system is developed according to the Total Revenue Requirement (TRR) method. The objective...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics