TITLE

A Simple Exoskeleton That Assists Plantarflexion Can Reduce the Metabolic Cost of Human Walking

AUTHOR(S)
Malcolm, Philippe; Derave, Wim; Galle, Samuel; De Clercq, Dirk
PUB. DATE
February 2013
SOURCE
PLoS ONE;Feb2013, Vol. 8 Issue 2, p1
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Even though walking can be sustained for great distances, considerable energy is required for plantarflexion around the instant of opposite leg heel contact. Different groups attempted to reduce metabolic cost with exoskeletons but none could achieve a reduction beyond the level of walking without exoskeleton, possibly because there is no consensus on the optimal actuation timing. The main research question of our study was whether it is possible to obtain a higher reduction in metabolic cost by tuning the actuation timing. Methodology/Principal Findings: We measured metabolic cost by means of respiratory gas analysis. Test subjects walked with a simple pneumatic exoskeleton that assists plantarflexion with different actuation timings. We found that the exoskeleton can reduce metabolic cost by 0.18±0.06 W kg−1 or 6±2% (standard error of the mean) (p = 0.019) below the cost of walking without exoskeleton if actuation starts just before opposite leg heel contact. Conclusions/Significance: The optimum timing that we found concurs with the prediction from a mathematical model of walking. While the present exoskeleton was not ambulant, measurements of joint kinetics reveal that the required power could be recycled from knee extension deceleration work that occurs naturally during walking. This demonstrates that it is theoretically possible to build future ambulant exoskeletons that reduce metabolic cost, without power supply restrictions.
ACCESSION #
87624319

 

Related Articles

  • Reproducibility of Plantar Pressure Distribution Data in Barefoot Running. Maiwald, Christian; Grau, Stefan; Krauss, Inga; Mauch, Marlene; Axmann, Detlef; Horstmann, Thomas // Journal of Applied Biomechanics;Feb2008, Vol. 24 Issue 1, p14 

    The aim of this study was to provide detailed information on rationales, calculations, and results of common methods used to quantify reproducibility in plantar pressure variables. Recreational runners (N = 95) performed multiple barefoot running trials in a laboratory setup, and pressure...

  • Direct Methods for Predicting Movement Biomechanics Based Upon Optimal Control Theory with Implementation in OpenSim. Porsa, Sina; Lin, Yi-Chung; Pandy, Marcus // Annals of Biomedical Engineering;Aug2016, Vol. 44 Issue 8, p2542 

    The aim of this study was to compare the computational performances of two direct methods for solving large-scale, nonlinear, optimal control problems in human movement. Direct shooting and direct collocation were implemented on an 8-segment, 48-muscle model of the body (24 muscles on each side)...

  • Trunks, Tongues, and Tentacles: Moving with Skeletons of Muscle. Smith, Kathleen K.; Kier, William M. // American Scientist;Jan/Feb89, Vol. 77 Issue 1, p28 

    Focuses on the skeletal support provided by muscles. Components of the skeletal system; Transmission of the force produced by muscle contraction; Movements of the human arm; Biomechanical properties of the organs; Structure of muscular hydrostats; Mechanics of movement.

  • The relationship between lower limb proprioceptive sense and locomotor skill acquisition. Qaiser, Taha; Chisholm, Amanda; Lam, Tania // Experimental Brain Research;Nov2016, Vol. 234 Issue 11, p3185 

    Sensorimotor integration is essential for controlling movement and acquiring new motor tasks in humans. The aim of this project was to understand how lower limb proprioceptive sense contributes to the acquisition of a skilled walking task. We assessed lower limb joint position and movement...

  • Biomechanics Corner: Orthoses vs biomechanics. Isaacs, Robert // Podiatry Now;Jan2012, Vol. 15 Issue 1, p14 

    The author discusses his views on the concept of musculoskeletal (MSK) podiatry, the work done in the field by podiatrists and the concepts of biomechanics and orthoses. He believes that the proportion of MSK patients who receive an orthotic from a National Health Service (NHS) clinic is...

  • Personal gas monitors.  // Professional Safety;Sep95, Vol. 40 Issue 9, p55 

    Presents a shirt-pocket-size GASMAN personal gas monitors test for combustible gas, oxygen and various toxic gases.

  • Microdetector for rapid changes of oxygen partial pressure ( pO2) during the respiratory cycle in small laboratory animals. Barnikol, W. K. R.; Gaertner, Th.; Weiler, N.; Burkhard, O. // Review of Scientific Instruments;Jul1988, Vol. 59 Issue 7, p1204 

    An oxygen microdetector suitable for respiratory experiments with small laboratory animals is described. Its principle structure is an O[sub 2]-sensitive dye layer. To measure pO[sub 2] the capability of O[sub 2] to quench the fluorescence of dyes is used. The instrumental dead space of the...

  • Single-gas monitors.  // Professional Safety;Oct95, Vol. 40 Issue 10, p55 

    Features Neotox-XL personal single-gas monitor from Neotronix, designed for use in confine space entry or for continuous protection in a hazardous area where one gas known to exist.

  • Respiratory monitoring. Carroll, Patricia; Moore, Amy Slugg // RN;May99, Vol. 62 Issue 5, p68 

    Discusses the use of capnography in respiratory gas monitoring. Evolution of the use of capnography; Reasons for the slow pace of capnography's adoption as a standard monitoring tool; Monitoring of arterial carbon dioxide levels using the tool; Minimization of potential errors.