TITLE

Comparison of Limb-length Discrepancy After THA: With and Without Computer Navigation

AUTHOR(S)
LICINI, DAVID J.; BURNIKEL, DAVID J.; MENEGHINI, R. MICHAEL; OCHSNER, JOHN L.
PUB. DATE
May 2013
SOURCE
Orthopedics;May2013, Vol. 36 Issue 5, pe543
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Limb-length discrepancy following total hip arthroplasty (THA) is often cited as a reason for patient dissatisfaction and for hip instability. Various intraoperative techniques have been described to help restore normal limb length after THA. The purpose of this study was to assess whether a computer-navigated surgical technique would help restore limb-length equality following THA. A retrospective study of 150 consecutive patients compared a free-hand (non-navigated) THA technique vs a computer-navigated THA technique. Each group contained 75 patients. The primary outcome measurement was limb-length discrepancy, which was evaluated using a digital anteroposterior pelvic radiograph. Secondary outcome measurements included a Harris Hip Score questionnaire and a single question evaluating the subjective feeling of the operative limb (longer, shorter, or equal). At a minimum 1-year follow-up, results showed that computer-navigated THA helped restore limb-length equality. An average leg-length difference of 0.3 mm (SD50.3 mm) was found with computer-navigated THA compared with a leg-length difference of 1.8 mm (SD50.7 mm) when a non-navigated THA was used. This was statistically significant. Both groups had similar Harris Hip Scores (computer-navigated group, 84.8; non-navigated group, 84.2; P5.835), and no difference was found between the 2 groups regarding the patient's perception of the operative limb length. This study demonstrated that computer-navigated THA resulted in improved restoration of normal limb length and limited significant outliers but did not show improvement in Harris Hip Scores or patient's perception of limb-length equality.
ACCESSION #
87602448

 

Related Articles

  • Limb-Length Measurement in Total Hip Arthroplasty Using a Calipers Dual Pin Retractor. Takigami, Iori; Itokazu, Mansho; Itoh, Yoshiki; Matsumoto, Kazu; Yamamoto, Takatoshi; Shimizu, Katsuji // Bulletin of the NYU Hospital for Joint Diseases;2008, Vol. 66 Issue 2, p107 

    Background: Limb-length inequality is not uncommon after total hip arthroplasty (THA) and may cause subjective problems for patients. During THA a stable reference point must be established to determine changes in leg length. Several methods have been useful in minimizing the incidence and...

  • Limb-length Discrepancy After Total Hip Arthroplasty: Novel Treatment and Proposed Algorithm for Care. Thakral, Rishi; Johnson, Aaron J.; Specht, Stacy C.; Conway, Janet D.; Issa, Kimona; Mont, Michael A.; Herzenberg, John E. // Orthopedics;Feb2014, Vol. 37 Issue 2, p101 

    Limb-length discrepancy after total hip arthroplasty (THA) leads to patient dissatisfaction and can be a cause of orthopedic surgery malpractice cases. Nonsurgical and surgical techniques exist to correct limb-length discrepancies. Two limb-lengthening methods were used to correct greater than...

  • Adjustment of leg length using imageless navigation THA software without a femoral tracker. Nishio, Shoji; Fukunishi, Shigeo; Fukui, Tomokazu; Fujihara, Yuki; Yoshiya, Shinichi // Journal of Orthopaedic Science;Mar2011, Vol. 16 Issue 2, p171 

    Background: Adjustment of leg length discrepancy is an important factor influencing the outcome of total hip arthroplasty (THA). However, leg length discrepancy after THA has been reported to be associated with inferior clinical outcome in previous studies. A new version of the imageless...

  • Improvement in Gait Parameters After Lengthening for the Treatment of Limb-Length Discrepancy. Russell, Byron E. // Physical Therapy;Sep1999, Vol. 79 Issue 9, p879 

    Presents an abstract of the study `Improvement in Gait Parameters After Lengthening for the Treatment of Limb-Length Discrepancy,' by A. Bhave, et al., which appeared in the 1999 issue of `Journal of Bone Joint Surgical American.'

  • No difference in clinical outcome, bone density and polyethylene wear 5-7 years after standard navigated vs. conventional cementfree total hip arthroplasty. Keshmiri, Armin; Schröter, Christoph; Weber, Markus; Craiovan, Benjamin; Grifka, Joachim; Renkawitz, Tobias // Archives of Orthopaedic & Trauma Surgery;May2015, Vol. 135 Issue 5, p723 

    Introduction: The purpose of this investigation was to compare clinical outcome, component loosening, polyethylene cup wear and periprosthetic bone mineral density between 'cup first' navigated and conventional cementless total hip arthroplasty (THA) 5-7 years after surgery. Materials and...

  • Limb Geometry After Elastic Stable Nailing for Pediatric Femoral Fractures. Hamed Salem, Khaled; Keppler, Peter // Journal of Bone & Joint Surgery, American Volume;Jun2010, Vol. 92-A Issue 6, p1409 

    Background: Elastic stable intramedullary nailing has become a popular treatment for pediatric long–bone fractures. However, early limb malalignment and length differences may occur in children with femoral fractures who are managed with this procedure. Methods: We prospectively followed...

  • Limb-Length Discrepancy After Hip Arthroplasty. Ng, Vincent Y.; Kean, John R.; Glassman, Andrew H. // Journal of Bone & Joint Surgery, American Volume;8/7/2013, Vol. 95-A Issue 15, p1426 

    The article discusses the symptomatic limb-length discrepancy after the total hip arthroplasty. It states the neurologic manifestations from sciatic nerve which occurs with true lengthening of involved length. It cites the postoperative instability with limb-length discrepancy arise as result of...

  • CEMENTLESS TOTAL HIP ARTHROPLASTY AND LIMB-LENGTH EQUALIZATION IN PATIENTS WITH UNILATERAL CROWE TYPE-IV HIP DISLOCATION. Kuo-An Lai; Wun-Jer Shen; Lee-Wen Huang; Meng-Yi Chen // Journal of Bone & Joint Surgery, American Volume;Feb2005, Vol. 87-A Issue 2, p339 

    Background: Total hip arthroplasty in patients with unilateral congenital high dislocation of the hip (Crowe type IV) presents many challenges, including the problem of a marked limb-length discrepancy. The purpose of this retrospective study was to analyze the results of total hip replacement...

  • Computed Tomography Assessment of Image-free Navigation-assisted Cup Placement in THA in an Asian Population. Kim, Tae-Hoon; Lee, Suk-Ha; Yang, Jae-Hyuk; Oh, Kwang-Jun // Orthopedics;Oct2012, Vol. 35 Issue 10, p13 

    The authors hypothesized that an image-free navigation system would be more accurate than postoperative 3-dimensional (3-D) reconstructed computed tomography (CT) for acetabular cup inclination and anteversion during total hip arthroplasty (THA) in an Asian population. Eighty-one THAs were...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sign out of this library

Other Topics