TITLE

FRONT END TO METALS ANALYSIS

AUTHOR(S)
DePalma, Angelo
PUB. DATE
April 2013
SOURCE
Lab Manager Magazine;Apr2013, Vol. 8 Issue 3, p50
SOURCE TYPE
Periodical
DOC. TYPE
Article
ABSTRACT
The article focuses on microwave-acid digestion, a sample preparation method for atomic emission, atomic absorption, and metal analysis. It says that the use of strong acids and high temperature makes microwave digestion processes faster compared with hot plate digestion. PerkinElmer product manager Mike DiVito sees the technique as a complete way of inorganic sample preparation. It cites the Multiware ECO microwave system fro Anton Paar.
ACCESSION #
87591130

 

Related Articles

  • Rules and Regulations: FEDERAL COMMUNICATIONS COMMISSION.  // Federal Register (National Archives & Records Service, Office of;2/01/2013, Vol. 78 Issue 22, p7278 

    The article focuses on the document released by the U.S. Federal Communications Commission (FCC) concerning the approval by the U.S. Office of Management and Budget (OMB) on the use of microwave for wireless backhaul and the addition of flexibility to operational fixed microwave licensees and...

  • Sample Preparation.  // LC-GC North America;Aug2012 Buyer's Guide, Vol. 30, p758 

    The authors discuss various aspects of sample preparations (SP) and techniques for optimum results while chromatographic analysis. They state that food testing and environment analysis are the areas where the need of SPs is growing fastest. They also explain that SP techniques are easier to fit...

  • Phosphopeptide Enrichment by Covalent Chromatography after Derivatization of Protein Digests Immobilized on Reversed-Phase Supports. Nika, Heinz; Nieves, Edward; Hawke, David H.; Angeletti, Ruth Hogue // Journal of Biomolecular Techniques;Sep2013, Vol. 24 Issue 3, p154 

    A rugged sample-preparation method for comprehensive affinity enrichment of phosphopeptides from protein digests has been developed. The method uses a series of chemical reactions to incorporate efficiently and specifically a thiol-functionalized affinity tag into the analyte by barium hydroxide...

  • Faster, Better Sample Prep for Foodstuffs. Kaufmann, A.; Maden, K.; Walker, S. // Laboratory Equipment;Jan2014, Vol. 50 Issue 10, p28 

    The article discusses the efficiency and effectiveness of centrifugal evaporation as a sample preparation method in food analysis. It states that food analysis are required by the European Union (EU) in 1995 on concerns regarding the prohibition of nitrofuran antibiotics in foods. Moreover, the...

  • Electrical Potential as a Driving Force in Sample Preparation. Majors, Ronald E. // LC-GC North America;Jan2014, Vol. 32 Issue 1, p14 

    The article presents several preparation methods to remove the interferences and concentrate analytes of interest. These includes the electroextraction (EE), a sample enrichment technique that focus on changed analytes from large volume of aqueous phase. The electroenhanced solid-phase...

  • Novel nanosample preparation with a helium ion microscope. Rudneva, Maria; van Veldhoven, Emile; Malladi, Sairam K.; Maas, Diederik; Zandbergen, Henny W. // Journal of Materials Research;Apr2013, Vol. 28 Issue 8, p1013 

    In this article, we present novel sample preparation methods using a helium ion microscope (HIM). We report the possibility of reshaping, at room temperature, thin metal lines on an electron-transparent membrane: A set of platinum bridges with standard geometry (300 × 200 × 15 nm) was...

  • Specific magnetic isolation for direct detection of HPV16. Peeters, S.; Stakenborg, T.; Colle, F.; Liu, C.; Lagae, L.; Ranst, M. // European Journal of Clinical Microbiology & Infectious Diseases;Apr2012, Vol. 31 Issue 4, p539 

    Finding a suitable DNA purification system is vital for the success of many PCR based diagnostic tests. This report demonstrates the value of magnetic beads in combination with real-time PCR for the sequence-specific isolation and detection of episomal HPV16 DNA. In order to maximize the...

  • Streamline Your Sample Preparation. Ratcliff, Joanne // Bioscience Technology;11/21/2014, p1 

    The article discusses out-of-specification (OSS) errors, which occur during sample preparations, which impact the profitability and reputation of the pharmaceutical company. Topics discussed include reference of the Barr Labs court case due to which the U.S. Food and Drug Administration (FDA) to...

  • One Step Ahead with Lab Automation. Freisinger, Robert // Paint & Coatings Industry;Aug2012, Vol. 28 Issue 8, p26 

    The article offers insights on laboratory automation for coatings manufacturers. They should know which of their processors can be designed differently to improve key performance indicators (KPIs). Automated solutions can be used for repetitive tasks so that personnel can focus on innovation and...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library