TITLE

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS DETERMINATION OF PARACETAMOL AND IBUPROFEN IN FIXED DOSE COMBINATIONS

AUTHOR(S)
Tsvetkova, Boyka G.; Pencheva, Ivanka P.; Zlatkov, Alexander B.; Peikov, Plamen T.
PUB. DATE
September 2012
SOURCE
International Journal of Pharmaceutical Sciences Review & Resear;Sep/Oct2012, Vol. 16 Issue 1, p13
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
In this study, high performance liquid chromatographic method have been developed and validated for the simultaneous determination of Paracetamol and Ibuprofen in combined pharmaceutical formulations. The chromatography was carried out on a C18 (250 mm × 4.6 mm, 10 μm) column with methanol and 0.05 M sodium dihydrogen phosphate (65:35 v/v) as mobile phase, at a flow rate of 1.0 ml/min, with detection at 230 nm. Separation was complete in less than 8 min. The calibration curves were linear in the concentration range of 50.00-400.0 μg/ml for paracetamol and 20.00-160.0 μg/ml for ibuprofen. The % recovery for paracetamol and ibuprofen is in the range between 99.53 and 99.83 with RSD values not greater than 0.62. The results of the studies showed that the proposed RP-HPLC method is simple, rapid, precise and accurate, which can be applied for the routine assessment of paracetamol and ibuprofen in pharmaceutical dosage forms.
ACCESSION #
87366748

 

Related Articles

  • HPLC method modification and validation for quantification of Ibuprofen. Abdullah, Ghassan Z.; Abdulkarim, Muthanna F.; Salman, Ibrahim M.; Ameer, Omar Z.; Chtneni, Mallikarjun; Mahdi, Elrashid S.; Yam, Mun F.; Hameem, Sakeena; Basri, Mahiran; Sattar, Munavvar A.; Noor, Azmin M. // International Journal of Advances in Pharmaceutical Sciences;Oct2010, Vol. 1 Issue 4, p404 

    Among the various NSAIDs used in the treatment of joint pain and osteoarthritis, ibuprofen, a propionic acid derivative, has been widely used for these purposes. In the present investigation, we modified and validated an HPLC method to obtain an accurate, sensitive and precise procedure to be...

  • A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY OF ACTIVE COMPONENT IN PARACETAMOL SYRUP CONTAMINATED BY PENICILLIUM EXPANSUM. Brooks, A. A.; Antai, S. P.; Ebong, P. // Canadian Journal of Pure & Applied Sciences;Oct2012, Vol. 6 Issue 3, p2131 

    In this study, a high performance liquid chromatographic assay was carried out at room temperature to determine the concentration of active ingredient in paracetamol syrup contaminated by Penicillium expansum. The drug samples were extracted in methanol while the mobile phase was methanol: water...

  • Simultaneous Determination of Paracetamol, Chlorzoxazone and Diclofenac Sodium in Tablet Dosage Form by High Performance Liquid Chromatography. BADGUJAR, MADHUKAR A.; PINGALE, SATISH G.; MANGAONKAR, KIRAN V. // E-Journal of Chemistry;2011, Vol. 8 Issue 3, p1206 

    A simple, precise and rapid isocratic reverse phase high performance liquid chromatographic method was developed for the simultaneous determination of paracetamol, chlorzoxazone and diclofenac sodium from tablet dosage form. The chromatographic separation was performed on an inertsil C18 column...

  • Validated RP-HPLC Method for Estimation of Aceclofenac, Paracetamol and Chlorzoxazone in Dosage Form. Rathinavel, G.; Priyadarsini, R.; Thakur, D.; Premanand, D. C.; Valarmathy, J.; Hemalatha, S.; Senthilkumar, K. L.; Samueljoshua, L. // Der Pharma Chemica;2010, Vol. 2 Issue 2, p286 

    A simple, reproducible and efficient reverse phase high performance liquid chromatography (RP-HPLC) method has been developed for estimation of Aceclofenac, Paracetamol and Chlorzoxzone in its tablet dosage forms. Separation was done by using mobile phase consists of pH 2.8 buffer solution. The...

  • Application of HPLC for the Simultaneous Determination of Aceclofenac, Paracetamol and Tramadol Hydrochloride in Pharmaceutical Dosage Form. Chandra, Preeti; Rathore, Atul Singh; Lohidasan, Sathiyanarayanan; Mahadik, Kakasaheb Ramoo // Scientia Pharmaceutica;Apr2012, Vol. 80 Issue 2, p337 

    A simple, precise and accurate reversed-phase liquid chromatographic method has been developed for the simultaneous estimation of aceclofenac (ACF), paracetamol (PCM) and tramadol hydrochloride (TRM) in pharmaceutical dosage form. The chromatographic separation was achieved on a HiQ-Silâ„¢...

  • High Performance Liquid Chromatographic Assay method for the determination of Paracetamol and Caffeine in Tablet Formulation-in vitro dissolution studies. Sharma, S.; Sharma, M. C.; Sharma, R.; Sharma, A. D. // Journal of Pharmacy Research;May2011, Vol. 4 Issue 5, p1559 

    A simple high performance liquid chromatographic method has been developed and subsequently validated for simultaneous determination of Paracetamol and Caffeine in combination. The mobile phase was prepared by mixing solvents, Methanol Buffer (70:30) v/v ratio. The Buffer consists of equal...

  • Simultaneous estimation of paracetamol and lornoxicam by RP-HPLC method from combined dosage forms. Mokale, Santosh N.; Nirmal, Surekha S.; Lahoti, Swaroop R.; Sangshetti, Jaiprakash N. // Der Pharmacia Sinica;2011, Vol. 2 Issue 5, p138 

    A simple, rapid and precise reverse phase high performance liquid chromatographic method was developed for simultaneous estimation of Paracetamol (PL) and Lornoxicam (LO) in combined tablet dosage form. Formulation containing PL and Chromatography was performed on a 150 mm x 4.6 mm, 5-µm...

  • Quantification of Arbutin from Pear Blossoms by HPLC. Li Yuan; Qiao Jin-chun; Zhang Yu-xing; He Tong-sen; Ming-xia, L. V.; Zhang Fei; Cui Tong // Natural Product Research & Development;Jan2012, Vol. 24 Issue 1, p76 

    The contents of arbutin in pear blossoms of different periods and different varieties were detected using the HPLC method with Hypersil BDS C18 column (4.6 mm x 250 mm,5 µm) ,the mobile phase methanol :water (6: 94, with 0.05% formic acid) ,and the detection wavelength 280 urn. The results...

  • Determination of Gentamicin Released from Orthopedic Carrier System by a Novel HPLC Method. Laki; Ludányi; Hajdú; Zahár; Szendri; Klebovich; Antal // Journal of Chromatographic Science;Mar2011, Vol. 49 Issue 3, p177 

    A new, fast high-performance liquid chromatograpic-UV method has been developed and validated for quantitative analysis of gentamicin carrier samples drawn in drug release studies. The samples of the calibration curve were prepared in physiological salt solution, which were applied as...