ABSTRACT
Since its description by Paul Grammont from Dijon, France, several tens of thousands of reverse total shoulder arthroplasties (RTSA) have been performed for diverse conditions. The purpose of this analysis is to identify the complications of this procedure in the literature and in clinical practice. A total of 240 papers concerning RTSA published between 1996 and 2012 have been identified. Over 80 papers describe complications associated with this type of implant. A list of prostheses satisfying European and US standards, CE and FDA approved, has been produced on the basis of information provided by the manufacturers. Data from the literature do not support a meta-analysis. The inventory of best practices shows excellent results in the short and medium term in specific indications, while the number of complications varies between 10 and 65 % in long-term series. Complications can be classified into (A) non-specific including infections (superficial and deep), phlebitis, haematoma, neurological complications of the suprascapular, radial and axillary nerves and (B) specific complications associated with RTSA including (1) on the glenoid side: intraoperative fracture of the glenoid and acromion, late fracture of the scapula, impingement at the scapular neck (notching), glenoid loosening, dissociation of the glenoid component (snatching of the glenosphere) and fractures of the glenoid baseplate; (2) on the humeral side: metaphyseal deterioration, humeral loosening, instability of the shoulder, stiffness with limitation of external and/or internal rotation; and (3) muscular complications with fatty degeneration of the deltoid. Additionally we have identified specific situations related to the type of implant such as the disassembly of the humeral or the glenoid component, dissociation of the polyethylene humeral plate, dissociation of the metaphysis and osteolysis of the tuberosities. The integration of results from different clinical series is difficult because of the lack of a database and the multitude of implants used.
ACCESSION #
87087679

 

Related Articles

  • Reverse Total Shoulder Arthroplasty: Current Concepts, Results, and Component Wear Analysis. Nam, D.; Kepler, C. K.; Neviaser, A. S.; Jones, K. J.; Wright, T. M.; Craig, E. V.; Warren, R. F. // Journal of Bone & Joint Surgery, American Volume;2010 Supplement 2, Vol. 92-A, p23 

    The article presents a research study on the new concepts, results and component wear analysis of reverse total shoulder arthroplasty. Clinical outcomes of the said arthroplasty show significant results in treating pseudoparalysis of shoulder elevation associated with a massive rotator cuff...

  • Evaluation of silicon nitride as a wear resistant and resorbable alternative for total hip joint replacement. Olofsson, Johanna; Grehk, T. Mikael; Berlind, Torun; Persson, Cecilia; Jacobson, Staffan; Engqvist, H�kan // Biomatter;Apr-May2012, Vol. 2 Issue 2, p94 

    Many of the failures of total joint replacements are related to tribology, i.e., wear of the cup, head and liner. Accumulation of wear particles at the implants can be linked to osteolysis which leads to bone loss and in the end aseptic implant loosening. Therefore it is highly desirable to...

  • Inhibiting wear particles-induced osteolysis with naringin. Yu, Xiaowei; Zhao, Xingwei; Wu, Tianyi; Zhou, Zubin; Gao, Youshui; Wang, Xinfu; Zhang, Chang-Qing // International Orthopaedics;Jan2013, Vol. 37 Issue 1, p137 

    Purpose: The purpose of this study was to determine the effects of naringin on osteoclastogenesis and osteolysis both in vitro and in vivo. Methods: In this research osteoclasts were generated from mouse bone marrow monocytes with the receptor activator of NF-КB ligand and the macrophage...

  • Analysis of wear and oxidation on retrieved bipolar polyethylene liner. Katsutoshi Hara; Nobuhiro Kaku; Hiroshi Tsumura; Takehiko Torisu // Journal of Orthopaedic Science;Jul2008, Vol. 13 Issue 4, p366 

    Abstract Background  For bipolar prostheses, most of the previous studies attributed the occurrence of osteolysis to wear debris generated from the bearing surface. We looked closely into the wear debris and reported on our findings with respect to the oxidation index and the rate of wear...

  • Titanium Particles Stimulate Bone Resorption by Inducing Differentiation of Murine Osteoclasts. Yanming Bi; Van De Motter, Renee; Ragab, Ashraf A.; Goldberg, Victor M.; Anderson, James M.; Greenfield, Edward M. // Journal of Bone & Joint Surgery, American Volume;Apr2001, Vol. 83-A Issue 4, p501 

    Background: Loosening of orthopaedic implants is mediated by cytokines that elicit bone resorption and are produced in response to phagocytosis of implant-derived wear particles. This accelerated bone resorption could be due to increased osteoclastic activity, survival, or differentiation....

  • Expansion of CD14+CD16+ peripheral monocytes among patients with aseptic loosening. Wu, W.; Zhang, X.; Tang, T.; Ren, W. // Inflammation Research;Sep2009, Vol. 58 Issue 9, p561 

    Abstract Objective and design  In this study, we have investigated the relevance of peripheral blood inflammatory CD14+CD16+ monocytes phenotype to patients with aseptic loosening (AL). Material and treatment  Immunophenotypes of monocytes were examined among patients with AL...

  • Wear studies on the likely performance of CFR-PEEK/CoCrMo for use as artificial joint bearing materials. Scholes, S. C.; Unsworth, A. // Journal of Materials Science: Materials in Medicine;Jan2009, Vol. 20 Issue 1, p163 

    It is well known that a reduction in the volume of wear produced by articulating surfaces in artificial joints is likely to result in a lower incidence of failure due to wear particle induced osteolysis. Therefore, new materials have been introduced in an effort to produce bearing surfaces with...

  • Millennium watch.  // Discover;Jan2000, Vol. 21 Issue 1, p28 

    Cites' doctors experiments with combinations of ceramic, metal and plastic to create low-friction artificial joints.

  • In vivo distraction forces in extendible endoprosthetic replacements--a study of 34 patients. Meswania, J M; Walker, P S; Sneath, R S; Grimer, R J // Proceedings of the Institution of Mechanical Engineers -- Part H;Jul98, Vol. 212 Issue 3, p151 

    Using an instrumented distraction tool 34 extendible endoprosthetic replacements were lengthened to measure total resistance to extension. The study consisted of 19 distal femoral, 2 proximal femoral, 1 total femoral, 8 proximal tibial, 1 distal humeral, 2 proximal humeral and 1 total humeral...