TITLE

A poly(dimethylsiloxane) based prism for surface plasmon resonance imaging system and its application for gas detection

AUTHOR(S)
Zhang, L. L.; Chen, X.; Sun, J. H.; Cai, H. Y.; Li, H.; Chao, Y. P.; Cui, D. F.
PUB. DATE
March 2013
SOURCE
Review of Scientific Instruments;Mar2013, Vol. 84 Issue 3, p035001
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
This paper presents a surface plasmon resonance (SPR) imaging system based on a low-cost, convenient poly(dimethylsiloxane) (PDMS) prism featured with a close contact with the gold film. Compared to conventional glass prism, both numerical simulations and experimental studies indicated a deeper but wider absorption peak with a higher coupling angle for the PDMS based prism. System repeatability was quantified by the cycled detection of helium and air, with the effect of the flow rate investigated. Furthermore, five types of gases (nitrogen, air, oxygen, hydrogen, and helium) were detected and differentiated by the SPR system, with a calculated sensitivity of 5 × 10-6 RIU.
ACCESSION #
86446705

 

Related Articles

  • Double plasmon resonance in spherical metal-dielectric-metal nanostructures. Sidorov, A. I. // Technical Physics;Apr2006, Vol. 51 Issue 4, p477 

    Results are presented from numerical simulations of the optical properties of spherical nanostructures consisting of a metal core and two shells—dielectric and metal. A study is made of nanostructures with Ag, Al, and Cu cores and an outer Ag shell. It is shown that, for certain ratios...

  • Detection of nano-confined DNA using surface-plasmon enhanced fluorescence. Cloutier, Sylvain G.; Lazareck, Adam D.; Xu, Jimmy // Applied Physics Letters;1/2/2006, Vol. 88 Issue 1, p013904 

    Surface-plasmon resonance (SPR)-induced enhanced fluorescence was used to detect the presence of fluorescent TOTO-1 bis-intercalated lambda-DNA complexes introduced into a periodic nanopore array. As we show, the proposed technique allows a high detection sensitivity by providing a strong...

  • Interference of surface plasmon polaritons controlled by the phase of incident light. Xi-Feng Ren; Guo-Ping Guo; Yun-Feng Huang; Zhi-Wei Wang; Pei Zhang; Guang-Can Guo // Applied Physics Letters;4/28/2008, Vol. 92 Issue 17, p171106 

    Interference patterns of surface plasmon polaritons (SPPs) are observed in the extraordinary optical transmission through subwavelength holes in an optically thick metal plate. It is found that the phase of incident light can be transferred to SPPs. We can control the destructive and...

  • Broadband wide-angle dispersion measurements: Instrumental setup, alignment, and pitfalls. Farhang, A.; Abasahl, B.; Dutta-Gupta, S.; Lovera, A.; Mandracci, P.; Descrovi, E.; Martin, O. J. F. // Review of Scientific Instruments;Mar2013, Vol. 84 Issue 3, p033107 

    The construction, alignment, and performance of a setup for broadband wide-angle dispersion measurements, with emphasis on surface plasmon resonance (SPR) measurements, are presented in comprehensive detail. In contrast with most SPR instruments working with a monochromatic source, this setup...

  • Localized surface plasmon resonance biosensing by electro-optic modulation with sensitivity and resolution tunability. Tzyy-Jiann Wang; Po-Ching Ho // Journal of Applied Physics;Mar2011, Vol. 109 Issue 6, p064703 

    The authors demonstrate a localized surface plasmon resonance (LSPR) biosensing technique based on electro-optically modulated attenuated total reflection. Electro-optic effect is utilized to modulate the wavevector of the light for exciting LSPR with the initial wavevector specified by setting...

  • High-Sensitivity Refractive Index Sensor Based on D-Shaped Photonic Crystal Fiber with Rectangular Lattice and Nanoscale Gold Film. An, Guowen; Li, Shuguang; Qin, Wei; Zhang, Wan; Fan, Zhenkai; Bao, Yajie // Plasmonics;Dec2014, Vol. 9 Issue 6, p1355 

    We propose and investigate a D-shaped photonic fiber refractive index sensor with rectangular lattice based on surface plasmon resonance. In such sensor, the nanoscale gold metal film is deposited on the flat surface where it is side polished. Numerical results show that the average sensitivity...

  • One-dimensional surface plasmon resonance imaging system using wavelength interrogation. Fu, Elain; Ramsey, Stephen; Thariani, Rahber; Yager, Paul // Review of Scientific Instruments;Jul2006, Vol. 77 Issue 7, p076106 

    We report on a one-dimensional surface plasmon resonance imaging system that can measure reflectivity over a range of incident wavelengths on multiple samples in parallel. The design and operation of the instrument are described and two methods of quantification are demonstrated.

  • Two-prism setup for surface plasmon resonance studies. Mohanty, Bhaskar Chandra; Kasiviswanathan, S. // Review of Scientific Instruments;Mar2005, Vol. 76 Issue 3, p033103 

    A two-prism experimental arrangement having wide angular scan ranges for the study of surface plasmon resonance is presented. The setup has a single rotating element instead of a high cost goniometer and a stationary photodetector which is positioned such that it always receives the reflected...

  • Signal Amplification by Enzymatic Reaction in an Immunosensor Based on Localized Surface Plasmon Resonance (LSPR). Tae-Han Lee; Seung-Woo Lee; Ji-Ae Jung; Junhyoung Ahn; Min-Gon Kim; Yong-Beom Shin // Sensors (14248220);2010, Vol. 10 Issue 3, p2045 

    An enzymatic reaction was employed as a means to enhance the sensitivity of an immunosensor based on localized surface plasmon resonance (LSPR). The reaction occurs after intermolecular binding between an antigen and an antibody on gold nano-island (NI) surfaces. For LSPR sensing, the gold NI...